AOKOL vs Emeric heat pumps
Measured against models of the same size and duct type, Emeric scores higher on 4 of the 6 ratings. AOKOL has 4 outdoor models, Emeric has 4 outdoor models. AOKOL and Emeric have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AOKOL
- Emeric
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AOKOL | Emeric |
|---|---|---|
| Efficiency index | 58%median — | 70%median — |
| COP at 5°F | 52%median 2.00 | 79%median 2.23 |
| Capacity retention at 5°F | 41%median 72% | 57%median 76% |
| HSPF2 | 65% (higher)median 10.3 | 63% (higher)median 9.0 |
| SEER2 | 77% (higher)median 23.3 | 74% (higher)median 18.5 |
| EER2 | 49%median 11.6 | 74%median 12.0 |
| Heating capacity at 5°F | 39%median 22,900 Btu/h | 51%median 26,500 Btu/h |
| Outdoor models | 4 | 4 |
| AHRI certifications | 4 | 6 |
Share of models meeting each standard
| Standard | AOKOL | Emeric |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%4 models | 100%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%4 models | 100%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%4 models | 100%4 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 100%4 models | 100%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AOKOL
- Emeric
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AOKOL | Emeric |
|---|---|---|
| Ducted, 2 tons | None | 2 · index 68% |
| Ducted, 3.5–4.5 tons | None | 2 · index 73% |
| Non-ducted, up to 1.5 tons | 1 · index 72% | None |
| Non-ducted, 2.5–3 tons | 2 · index 58% | None |
| Non-ducted, 3.5–4.5 tons | 1 · index 42% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AOKOLCold-climate score, best model | EmericCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 60.2(50 is the typical model of its size class)ETD-H36DMR3with ducted air handler EAH-C24DMR3Also listed as ETD-H24DMR32 of 2 models qualify · AHRI 216699935 |
| Ducted, 3.5–4.5 tons | No models in this size class | 72.2(50 is the typical model of its size class)ETD-H60DMR3with ducted air handler EAH-C48DMR3Also listed as ETD-H48DMR32 of 2 models qualify · AHRI 216699937 |
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)AOODU-1D2S1 of 1 models qualify · AHRI 217496788 | No models in this size class |
| Non-ducted, 2.5–3 tons | 57.5(50 is the typical model of its size class)AOODU-1D3S2 of 2 models qualify · AHRI 217496789 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 31.2(50 is the typical model of its size class)AOODU-1D5S1 of 1 models qualify · AHRI 217496791 | No models in this size class |
All-around best
| Size and duct type | AOKOLAll-around score, best model | EmericAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 67.9(50 is the typical model of its size class)ETD-H36DMR3with ducted air handler EAH-C24DMR3Also listed as ETD-H24DMR32 of 2 models have all five ratings · AHRI 216699935 |
| Ducted, 3.5–4.5 tons | No models in this size class | 72.6(50 is the typical model of its size class)ETD-H60DMR3with ducted air handler EAH-C48DMR3Also listed as ETD-H48DMR32 of 2 models have all five ratings · AHRI 216699937 |
| Non-ducted, up to 1.5 tons | 72.2(50 is the typical model of its size class)AOODU-1D2S1 of 1 models have all five ratings · AHRI 217496788 | No models in this size class |
| Non-ducted, 2.5–3 tons | 65.1(50 is the typical model of its size class)AOODU-1D3S2 of 2 models have all five ratings · AHRI 217496789 | No models in this size class |
| Non-ducted, 3.5–4.5 tons | 42.4(50 is the typical model of its size class)AOODU-1D5S1 of 1 models have all five ratings · AHRI 217496791 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AOKOL | Emeric |
|---|---|---|
| COP at 5°F | beats 63% · 2.00AOODU-1D2SNon-ducted, up to 1.5 tons | beats 86% · 2.30ETD-H60DMR3Also listed as ETD-H48DMR3Ducted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 61% · 80%AOODU-1D2SNon-ducted, up to 1.5 tons | beats 56% · 79%ETD-H36DMR3Also listed as ETD-H24DMR3Ducted, 2 tons |
| HSPF2 | beats 80% · 10.5AOODU-1D3SNon-ducted, 2.5–3 tons | beats 74% · 9.2ETD-H60DMR3Also listed as ETD-H48DMR3Ducted, 3.5–4.5 tons |
| SEER2 | beats 91% · 24.0AOODU-1D3SNon-ducted, 2.5–3 tons | beats 81% · 18.5ETD-H60DMR3Also listed as ETD-H48DMR3Ducted, 3.5–4.5 tons |
| EER2 | beats 70% · 13.0AOODU-1D2SNon-ducted, up to 1.5 tons | beats 81% · 12.5ETD-H36DMR3Also listed as ETD-H24DMR3Ducted, 2 tons |
| Heating capacity at 5°F | beats 88% · 16,000 Btu/hAOODU-1D2SNon-ducted, up to 1.5 tons | beats 68% · 40,000 Btu/hETD-H60DMR3Ducted, 3.5–4.5 tons |