- Insights
- Manufacturers
- Enerwave
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Enerwave heat pump efficiency: 14 outdoor models compared
Enerwave has 14 heat pump outdoor models certified with this refrigerant group, in 14 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Enerwave makes. Enerwave has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 14
- AHRI certifications
- 14
- Efficiency index
- 22%
- Typical model vs same-size, same-type peers (14 models)
- Meet CEE 2025
- 0%
- 0 models
How Enerwave compares with comparable models
- Enerwave
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index14 models scored | 22% | Not ranked | — |
| COP at 5°F14 models scored | 17% | Not ranked | 1.71 |
| Capacity retention at 5°F14 models scored | 31% | Not ranked | 72% |
| HSPF214 models scored | 36% | Not ranked | 9.2 |
| SEER214 models scored | 18% | Not ranked | 13.9 |
| EER214 models scored | 15% | Not ranked | 10.6 |
| Heating capacity at 5°F14 models scored | 10% | Not ranked | 5,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Enerwave (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 14 | 22% | 17% | 36% | 18% |
Every Enerwave model in the market
- Enerwave models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Enerwave models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1VD3SD18EWEnerwave · VSAlso listed as VD3SD27EW | 0.5 tons8,900 Btu/h · Ducted | 73% | 1.72 | 9.9 | 6,500 | 14.4 | None | 1 | 218418644 | Ducted, up to 1.5 tons | 43.8 |
| 2CS3SH06BEWEnerwave · CSAlso listed as CD3SD18EW, CD3MV18EW, CD3SD27EW, CD3MV27EW | 0.5 tons7,700 Btu/h · Ducted | 72% | 1.64 | 9.2 | 6,200 | 13.9 | None | 1 | 218418631 | Ducted, up to 1.5 tons | 28.0 |
| 3W3SH06AEWEnerwave · WMAlso listed as W3SHE06BEW, W3SHE08BEW, V4SH06AEW, V4SH06BEW | 0.5 tons7,400 Btu/h · Ducted | 72% | 1.71 | 7.1 | 5,300 | 13.7 | None | 1 | 218418625 | Ducted, up to 1.5 tons | 15.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1W2SH06AEWEnerwave · WM | 0.5 tons6,000 Btu/h · Ducted | 52% | 2.16 | 12.6 | 15.7 | 10.4 | None | 1 | 218418648 | Ducted, up to 1.5 tons | 46.5 | 62.2 | 30.9 | Not a pick |
| 2VD3SD18EWEnerwave · VSAlso listed as VD3SD27EW | 0.5 tons8,900 Btu/h · Ducted | 73% | 1.72 | 9.9 | 14.4 | 11.0 | None | 1 | 218418644 | Ducted, up to 1.5 tons | 35.1 | 43.8 | 26.3 | 43.8 |
| 3W3PHEF8BEWEnerwave · WM | 1 ton9,000 Btu/h · Ducted | 62% | 1.76 | 8.6 | 15.8 | 11.2 | None | 1 | 218418629 | Ducted, up to 1.5 tons | 33.7 | 25.4 | 42.0 | Not a pick |
| 4CS3SH06BEWEnerwave · CSAlso listed as CD3SD18EW, CD3MV18EW, CD3SD27EW, CD3MV27EW | 0.5 tons7,700 Btu/h · Ducted | 72% | 1.64 | 9.2 | 13.9 | 10.6 | None | 1 | 218418631 | Ducted, up to 1.5 tons | 21.6 | 28.0 | 15.3 | 28.0 |
| 5W3SH06AEWEnerwave · WMAlso listed as W3SHE06BEW, W3SHE08BEW, V4SH06AEW, V4SH06BEW | 0.5 tons7,400 Btu/h · Ducted | 72% | 1.71 | 7.1 | 13.7 | 9.2 | None | 1 | 218418625 | Ducted, up to 1.5 tons | 10.4 | 15.7 | 5.0 | 15.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | W2SH06AEW | 2.16 | Ducted, up to 1.5 tons | 79% | 218418648 |
| Capacity retention at 5°F | VD3SD18EWAlso listed as VD3SD27EW | 73% | Ducted, up to 1.5 tons | 44% | 218418644 |
| HSPF2 | W2SH06AEW | 12.6 | Ducted, up to 1.5 tons | 97% | 218418648 |
| SEER2 | W3PHEF8BEW | 15.8 | Ducted, up to 1.5 tons | 46% | 218418629 |
| EER2 | W3PHEF8BEW | 11.2 | Ducted, up to 1.5 tons | 31% | 218418629 |
| Heating capacity at 5°F | VD3SD18EWAlso listed as VD3SD27EW | 6,500 Btu/h | Ducted, up to 1.5 tons | 22% | 218418644 |
Enerwave size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 43.8(50 is the typical model of its size class)VD3SD18EWAlso listed as VD3SD27EW12 of 14 models qualify · AHRI 218418644 | 46.5(50 is the typical model of its size class)W2SH06AEW14 of 14 models have all five ratings · AHRI 218418648 |
Newest Enerwave certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| W2SH06AEWEnerwave · WM | 0.5 tons6,000 Btu/h · Ducted | 2.16 | 52% | 12.6 | 15.7 | None | 1 | 218418648 |
| VD3SD27EWEnerwave · VS | 0.5 tons8,900 Btu/h · Ducted | 1.72 | 73% | 9.9 | 14.4 | None | 1 | 218418646 |
| VD3SD18EWEnerwave · VS | 0.5 tons8,900 Btu/h · Ducted | 1.72 | 73% | 9.9 | 14.4 | None | 1 | 218418644 |
| CD3MV27EWEnerwave · CD | 0.5 tons7,700 Btu/h · Ducted | 1.64 | 72% | 9.2 | 13.9 | None | 1 | 218418643 |
| CD3SD27EWEnerwave · CD | 0.5 tons7,700 Btu/h · Ducted | 1.64 | 72% | 9.2 | 13.9 | None | 1 | 218418642 |
Compare Enerwave