Skip to content

Enerwave vs Trane/American Standard heat pumps

Measured against models of the same size and duct type, Trane/American Standard scores higher on 6 of the 6 ratings. Enerwave has 14 outdoor models, Trane/American Standard has 14 outdoor models. Enerwave and Trane/American Standard have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Enerwave and Trane/American Standard on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Trane/American Standard scores higher on 6 of the 6 ratings.
  • Enerwave
  • Trane/American Standard
  • Other ranked manufacturers
EnerwaveTrane/Am…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingEnerwaveTrane/American Standard
Efficiency index22%median —57%median —
COP at 5°F17%median 1.7157%median 2.05
Capacity retention at 5°F31%median 72%47%median 55%
HSPF236%median 9.259%median 8.7
SEER218%median 13.975%median 18.5
EER215%median 10.646%median 10.6
Heating capacity at 5°F10%median 5,900 Btu/h59%median 30,800 Btu/h
Outdoor models1414
AHRI certifications1414

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardEnerwaveTrane/American Standard
CEE 2025 Tier 1 (Split ASHP)0%0 models42.9%6 models
CEE 2026 Tier 1 (Split ASHP)0%0 models42.9%6 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models35.7%5 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models42.9%6 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 0 groups where both have models
  • Enerwave
  • Trane/American Standard
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeEnerwaveTrane/American Standard
Ducted, up to 1.5 tons14 · index 22%None
Ducted, 2 tonsNone4 · index 65%
Ducted, 2.5–3 tonsNone4 · index 61%
Ducted, 3.5–4.5 tonsNone6 · index 50%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeEnerwaveCold-climate score, best modelTrane/American StandardCold-climate score, best model
Ducted, up to 1.5 tons43.8(50 is the typical model of its size class)VD3SD18EWAlso listed as VD3SD27EW12 of 14 models qualify · AHRI 218418644No models in this size class
Ducted, 2 tonsNo models in this size class67.5(50 is the typical model of its size class)5HCL9024A1000A*with ducted air handler 5TEM9C02AC21SA2 of 4 models qualify · AHRI 217497614
Ducted, 2.5–3 tonsNo models in this size class76.5(50 is the typical model of its size class)5HCL9036A1000A*with ducted air handler 5TEM9D04AC31SA2 of 4 models qualify · AHRI 217497618
Ducted, 3.5–4.5 tonsNo models in this size class61.6(50 is the typical model of its size class)5HCL9048A1000A*with ducted air handler 5TEM9D06AC31SA2 of 6 models qualify · AHRI 217497615

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeEnerwaveAll-around score, best modelTrane/American StandardAll-around score, best model
Ducted, up to 1.5 tons46.5(50 is the typical model of its size class)W2SH06AEW14 of 14 models have all five ratings · AHRI 218418648No models in this size class
Ducted, 2 tonsNo models in this size class79.5(50 is the typical model of its size class)5HCL9024A1000A*with ducted air handler 5TEM9C02AC21SA4 of 4 models have all five ratings · AHRI 217497614
Ducted, 2.5–3 tonsNo models in this size class85.4(50 is the typical model of its size class)5HCL9036A1000A*with ducted air handler 5TEM9D04AC31SA4 of 4 models have all five ratings · AHRI 217497618
Ducted, 3.5–4.5 tonsNo models in this size class61.4(50 is the typical model of its size class)5HCL9048A1000A*with ducted air handler 5TEM9D06AC31SA6 of 6 models have all five ratings · AHRI 217497615

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingEnerwaveTrane/American Standard
COP at 5°Fbeats 79% · 2.16W2SH06AEWDucted, up to 1.5 tonsbeats 93% · 2.505HPL9036A1000A*Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 44% · 73%VD3SD18EWAlso listed as VD3SD27EWDucted, up to 1.5 tonsbeats 87% · 93%5HCL9024A1000A*Ducted, 2 tons
HSPF2beats 97% · 12.6W2SH06AEWDucted, up to 1.5 tonsbeats 70% · 9.25HCL9036A1000A*Ducted, 2.5–3 tons
SEER2beats 46% · 15.8W3PHEF8BEWDucted, up to 1.5 tonsbeats 98% · 21.25HCL9036A1000A*Ducted, 2.5–3 tons
EER2beats 31% · 11.2W3PHEF8BEWDucted, up to 1.5 tonsbeats 100% · 14.85HCL6024A1000A*Ducted, 2 tons
Heating capacity at 5°Fbeats 22% · 6,500 Btu/hVD3SD18EWAlso listed as VD3SD27EWDucted, up to 1.5 tonsbeats 98% · 26,000 Btu/h5HCL9024A1000A*Ducted, 2 tons

More comparisons