Skip to content

Hessaire vs Trane/American Standard heat pumps

Measured against models of the same size and duct type, Trane/American Standard scores higher on 5 of the 6 ratings. Hessaire has 14 outdoor models, Trane/American Standard has 14 outdoor models. Hessaire and Trane/American Standard have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Hessaire and Trane/American Standard on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Trane/American Standard scores higher on 5 of the 6 ratings.
  • Hessaire
  • Trane/American Standard
  • Other ranked manufacturers
HessaireTrane/Am…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingHessaireTrane/American Standard
Efficiency index50%median —57%median —
COP at 5°F50%median 1.9757%median 2.05
Capacity retention at 5°F55% (higher)median 76%47% (higher)median 55%
HSPF249%median 9.358%median 8.7
SEER254%median 20.575%median 18.5
EER242%median 11.546%median 10.6
Heating capacity at 5°F56%median 18,000 Btu/h59%median 30,800 Btu/h
Outdoor models1414
AHRI certifications2014

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardHessaireTrane/American Standard
CEE 2025 Tier 1 (Split ASHP)92.9%13 models42.9%6 models
CEE 2026 Tier 1 (Split ASHP)78.6%11 models42.9%6 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)71.4%10 models35.7%5 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate57.1%8 models42.9%6 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • Hessaire
  • Trane/American Standard
  • All models of the group
Ducted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeHessaireTrane/American Standard
Ducted, 2 tons1 · index 42%4 · index 65%
Ducted, 2.5 to 3 tons1 · index 44%4 · index 61%
Ducted, 3.5 to 4.5 tons2 · index 49%6 · index 50%
Non-ducted, up to 1.5 tons7 · index 50%None
Non-ducted, 2 tons2 · index 49%None
Non-ducted, 2.5 to 3 tons1 · index 66%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeHessaireCold-climate score, best modelTrane/American StandardCold-climate score, best model
Ducted, 2 tons52.1(50 is the typical model of its size class)HOC24Bwith ducted air handler HAH24B1 of 1 models qualify · AHRI 21749033167.3(50 is the typical model of its size class) (higher)5HCL9024A1000A*with ducted air handler 5TEM9C02AC21SA2 of 4 models qualify · AHRI 217497614
Ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)76.8(50 is the typical model of its size class)5HCL9036A1000A*with ducted air handler 5TEM9D04AC31SA2 of 4 models qualify · AHRI 217497618
Ducted, 3.5 to 4.5 tons60.6(50 is the typical model of its size class)HOC48Bwith ducted air handler HAH48B1 of 2 models qualify · AHRI 21749033361.4(50 is the typical model of its size class) (higher)5HCL9048A1000A*with ducted air handler 5TEM9D06AC31SA2 of 6 models qualify · AHRI 217497615
Non-ducted, up to 1.5 tons71.0(50 is the typical model of its size class)HM185 of 7 models qualify · AHRI 214728843No models in this size class
Non-ducted, 2 tons55.3(50 is the typical model of its size class)H24FB2with ductless indoor unit H24FB2-I2 of 2 models qualify · AHRI 218636280No models in this size class
Non-ducted, 2.5 to 3 tons53.5(50 is the typical model of its size class)HM271 of 1 models qualify · AHRI 214728844No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeHessaireAll-around score, best modelTrane/American StandardAll-around score, best model
Ducted, 2 tons42.1(50 is the typical model of its size class)HOC24Bwith ducted air handler HAH24B1 of 1 models have all five ratings · AHRI 21749033179.4(50 is the typical model of its size class) (higher)5HCL9024A1000A*with ducted air handler 5TEM9C02AC21SA4 of 4 models have all five ratings · AHRI 217497614
Ducted, 2.5 to 3 tons43.8(50 is the typical model of its size class)HOC36Bwith ducted air handler HAH36B1 of 1 models have all five ratings · AHRI 21749033285.6(50 is the typical model of its size class) (higher)5HCL9036A1000A*with ducted air handler 5TEM9D04AC31SA4 of 4 models have all five ratings · AHRI 217497618
Ducted, 3.5 to 4.5 tons55.2(50 is the typical model of its size class)HOC48Bwith ducted air handler HAH48B2 of 2 models have all five ratings · AHRI 21749033361.5(50 is the typical model of its size class) (higher)5HCL9048A1000A*with ducted air handler 5TEM9D06AC31SA6 of 6 models have all five ratings · AHRI 217497615
Non-ducted, up to 1.5 tons71.0(50 is the typical model of its size class)HM187 of 7 models have all five ratings · AHRI 214728843No models in this size class
Non-ducted, 2 tons63.1(50 is the typical model of its size class)H24FB2with ductless indoor unit H24FB2-I2 of 2 models have all five ratings · AHRI 218636280No models in this size class
Non-ducted, 2.5 to 3 tons66.1(50 is the typical model of its size class)HM271 of 1 models have all five ratings · AHRI 214728844No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingHessaireTrane/American Standard
COP at 5°Fbeats 98% · 2.50H18TT2Non-ducted, up to 1.5 tonsbeats 93% · 2.505HPL9036A1000A*Ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 88% · 100%HM18Non-ducted, up to 1.5 tonsbeats 87% · 93%5HCL9024A1000A*Ducted, 2 tons
HSPF2beats 69% · 9.0HOC48BDucted, 3.5 to 4.5 tonsbeats 70% · 9.25HCL9036A1000A*Ducted, 2.5 to 3 tons
SEER2beats 76% · 18.0HOC48BDucted, 3.5 to 4.5 tonsbeats 99% · 21.25HCL9036A1000A*Ducted, 2.5 to 3 tons
EER2beats 81% · 12.9HM27Non-ducted, 2.5 to 3 tonsbeats 100% · 14.85HCL6024A1000A*Ducted, 2 tons
Heating capacity at 5°Fbeats 94% · 18,000 Btu/hHM18Non-ducted, up to 1.5 tonsbeats 98% · 26,000 Btu/h5HCL9024A1000A*Ducted, 2 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter