- Insights
- Manufacturers
- Hessaire
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Hessaire heat pump efficiency: 14 outdoor models compared
Hessaire has 14 heat pump outdoor models certified with this refrigerant group, in 20 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Hessaire makes. Hessaire has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 14
- AHRI certifications
- 20
- Efficiency index
- 48%
- Typical model vs same-size, same-type peers (14 models)
- Meet CEE 2025
- 92.9%
- 13 models
How Hessaire compares with comparable models
- Hessaire
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index14 models scored | 48% | Not ranked | — |
| COP at 5°F14 models scored | 49% | Not ranked | 1.97 |
| Capacity retention at 5°F14 models scored | 54% | Not ranked | 76% |
| HSPF214 models scored | 48% | Not ranked | 9.3 |
| SEER214 models scored | 53% | Not ranked | 20.5 |
| EER214 models scored | 40% | Not ranked | 11.5 |
| Heating capacity at 5°F14 models scored | 54% | Not ranked | 18,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 92.9% | 13 |
| CEE 2026 Tier 1 (Split ASHP) | 78.6% | 11 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 71.4% | 10 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 57.1% | 8 |
Sizes and duct types offered
- Hessaire (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2 tons | 1 | 42% | 51% | 58% | 55% |
| Ducted, 2.5–3 tons | 1 | 45% | 56% | 68% | 62% |
| Ducted, 3.5–4.5 tons | 2 | 49% | 50% | 67% | 71% |
| Non-ducted, up to 1.5 tons | 7 | 48% | 55% | 43% | 44% |
| Non-ducted, 2 tons | 2 | 47% | 42% | 28% | 51% |
| Non-ducted, 2.5–3 tons | 1 | 65% | 14% | 59% | 76% |
Every Hessaire model in the market
- Hessaire models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Hessaire models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HM18Hessaire · Multi-Split | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.99 | 10.0 | 18,000 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 214728843 | Non-ducted, up to 1.5 tons | 69.5 |
| 2H18TT2Hessaire · ESwith ductless indoor unit H18TT2 | 1.5 tons18,000 Btu/h · Non-ducted | 76% | 2.50 | 9.8 | 13,700 | 21.0 | CEE 25CEE 26Xcel | 2 | 216699370 | Non-ducted, up to 1.5 tons | 69.1 |
| 3H18FB2Hessaire · ESwith ductless indoor unit H18FB2 | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.90 | 10.0 | 18,000 | 21.0 | CEE 25CEE 26XcelES CC | 2 | 216699366 | Non-ducted, up to 1.5 tons | 65.0 |
| 4HOC48BHessaire · Energy Starwith ducted air handler HAH48B | 4 tons48,000 Btu/h · Ducted | 73% | 2.00 | 9.0 | 35,000 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 217490333 | Ducted, 3.5–4.5 tons | 60.6 |
| 5H24FB2Hessaire · ESwith ductless indoor unit H24FB2-I | 2 tons24,000 Btu/h · Non-ducted | 80% | 2.00 | 9.5 | 19,200 | 22.5 | CEE 25CEE 26XcelES CC | 2 | 218636280 | Non-ducted, 2 tons | 54.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HM18Hessaire · Multi-Split | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.99 | 10.0 | 22.0 | 13.3 | CEE 25CEE 26XcelES CC | 1 | 214728843 | Non-ducted, up to 1.5 tons | 69.2 | 69.5 | 68.9 | 69.5 |
| 2HM27Hessaire · Multi-Split | 2.5 tons27,000 Btu/h · Non-ducted | 100% | 1.82 | 10.0 | 23.0 | 12.9 | CEE 25CEE 26XcelES CC | 1 | 214728844 | Non-ducted, 2.5–3 tons | 65.4 | 52.6 | 78.2 | 52.6 |
| 3H24FB2Hessaire · ESwith ductless indoor unit H24FB2-I | 2 tons24,000 Btu/h · Non-ducted | 80% | 2.00 | 9.5 | 22.5 | 12.3 | CEE 25CEE 26XcelES CC | 2 | 218636280 | Non-ducted, 2 tons | 61.3 | 54.1 | 68.4 | 54.1 |
| 4H18FB2Hessaire · ESwith ductless indoor unit H18FB2 | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.90 | 10.0 | 21.0 | 13.0 | CEE 25CEE 26XcelES CC | 2 | 216699366 | Non-ducted, up to 1.5 tons | 60.2 | 65.0 | 55.3 | 65.0 |
| 5H18TT2Hessaire · ESwith ductless indoor unit H18TT2 | 1.5 tons18,000 Btu/h · Non-ducted | 76% | 2.50 | 9.8 | 21.0 | 12.0 | CEE 25CEE 26Xcel | 2 | 216699370 | Non-ducted, up to 1.5 tons | 55.3 | 69.1 | 41.6 | 69.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | H18TT2 | 2.50 | Non-ducted, up to 1.5 tons | 98% | 216699370 |
| Capacity retention at 5°F | HM18 | 100% | Non-ducted, up to 1.5 tons | 87% | 214728843 |
| HSPF2 | HOC48B | 9.0 | Ducted, 3.5–4.5 tons | 69% | 217490333 |
| SEER2 | HOC48B | 18.0 | Ducted, 3.5–4.5 tons | 76% | 217490333 |
| EER2 | HM27 | 12.9 | Non-ducted, 2.5–3 tons | 80% | 214728844 |
| Heating capacity at 5°F | HM18 | 18,000 Btu/h | Non-ducted, up to 1.5 tons | 93% | 214728843 |
Hessaire size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 52.4(50 is the typical model of its size class)HOC24Bwith ducted air handler HAH24B1 of 1 models qualify · AHRI 217490331 | 42.2(50 is the typical model of its size class)HOC24Bwith ducted air handler HAH24B1 of 1 models have all five ratings · AHRI 217490331 |
| Ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | 44.7(50 is the typical model of its size class)HOC36Bwith ducted air handler HAH36B1 of 1 models have all five ratings · AHRI 217490332 |
| Ducted, 3.5–4.5 tons | 60.6(50 is the typical model of its size class)HOC48Bwith ducted air handler HAH48B1 of 2 models qualify · AHRI 217490333 | 54.9(50 is the typical model of its size class)HOC48Bwith ducted air handler HAH48B2 of 2 models have all five ratings · AHRI 217490333 |
| Non-ducted, up to 1.5 tons | 69.5(50 is the typical model of its size class)HM185 of 7 models qualify · AHRI 214728843 | 69.2(50 is the typical model of its size class)HM187 of 7 models have all five ratings · AHRI 214728843 |
| Non-ducted, 2 tons | 54.1(50 is the typical model of its size class)H24FB2with ductless indoor unit H24FB2-I2 of 2 models qualify · AHRI 218636280 | 61.3(50 is the typical model of its size class)H24FB2with ductless indoor unit H24FB2-I2 of 2 models have all five ratings · AHRI 218636280 |
| Non-ducted, 2.5–3 tons | 52.6(50 is the typical model of its size class)HM271 of 1 models qualify · AHRI 214728844 | 65.4(50 is the typical model of its size class)HM271 of 1 models have all five ratings · AHRI 214728844 |
Newest Hessaire certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| H24FB2Hessaire · ESwith ductless indoor unit H24FB2-I | 2 tons24,000 Btu/h · Non-ducted | 2.00 | 80% | 9.5 | 22.5 | CEE 25CEE 26XcelES CC | 2 | 218636280 |
| H18FB2Hessaire · ESwith ductless indoor unit H18FB2-I | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 9.5 | 21.0 | CEE 25CEE 26XcelES CC | 2 | 218636279 |
| H12FB1Hessaire · ESwith ductless indoor unit H12FB1-I | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 218636278 |
| H24TT2Hessairewith ductless indoor unit H24TT2-I | 2 tons24,000 Btu/h · Non-ducted | 1.90 | 76% | 9.0 | 19.5 | CEE 25CEE 26Xcel | 2 | 218636277 |
| H18TT2Hessaire · ESwith ductless indoor unit H18TT2-I | 1.5 tons18,000 Btu/h · Non-ducted | 2.40 | 74% | 9.8 | 20.0 | CEE 25CEE 26Xcel | 2 | 218636276 |
Compare Hessaire
Hessaire includes these brand names as listed in AHRI: Hessaire. Standards are checked against published thresholds; program rules beyond ratings are not checked.