First Co. heat pump efficiency: 21 outdoor models compared
First Co. has 21 heat pump outdoor models certified with this refrigerant group, in 61 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes First Co. makes. First Co. has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 21
- AHRI certifications
- 61
- Efficiency index
- 11%
- Typical model vs same-size, same-type peers (21 models)
- Meet CEE 2025
- 0%
- 0 models
How First Co. compares with comparable models
- First Co.
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index21 models scored | 11% | Not ranked | — |
| COP at 5°F21 models scored | 34% | Not ranked | 1.90 |
| Capacity retention at 5°F21 models scored | 12% | Not ranked | 49% |
| HSPF221 models scored | 1% | Not ranked | 6.3 |
| SEER221 models scored | 0% | Not ranked | 11.9 |
| EER221 models scored | 12% | Not ranked | 10.0 |
| Heating capacity at 5°F21 models scored | 14% | Not ranked | 8,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- First Co. (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 9% | 32% | 1% | 1% |
| Ducted, 2 tons | 7 | 13% | 40% | 0% | 1% |
| Ducted, 2.5–3 tons | 3 | 15% | 29% | 5% | 0% |
Every First Co. model in the market
- First Co. models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top First Co. models
Cold-climate picks
No First Co. model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 124WHHPBAFirst Co.with ducted air handler 37CLX(*,Q,W) | 2 tons23,000 Btu/h · Ducted | 55% | 1.90 | 6.8 | 13.5 | 12.0 | None | 18 | 216831932 | Ducted, 2 tons | 30.4 | 23.2 | 37.6 | Not a pick |
| 218WHHPBAFirst Co.with ducted air handler 37CLX(*,Q,W) | 1.5 tons18,500 Btu/h · Ducted | 42% | 1.50 | 6.8 | 14.2 | 12.5 | None | 17 | 216831931 | Ducted, up to 1.5 tons | 25.1 | 1.5 | 48.8 | Not a pick |
| 330WHHPBAFirst Co.with ducted air handler 37CLX(*,Q,W) | 2.5 tons27,200 Btu/h · Ducted | 48% | 1.80 | 6.8 | 13.2 | 11.3 | None | 8 | 216831933 | Ducted, 2.5–3 tons | 20.0 | 17.8 | 22.1 | Not a pick |
| 4EHE18***D***AFirst Co.Also listed as EHE18***E***A | 1.5 tons17,500 Btu/h · Ducted | 49% | 2.00 | 6.3 | 11.9 | 10.0 | None | 1 | 216831959 | Ducted, up to 1.5 tons | 14.6 | 23.8 | 5.5 | Not a pick |
| 5EHE24***D***BFirst Co.Also listed as EHE24***E***B | 2 tons24,400 Btu/h · Ducted | 51% | 2.00 | 6.3 | 11.9 | 10.0 | None | 1 | 216831960 | Ducted, 2 tons | 14.0 | 23.1 | 4.8 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | EHE12***D***AAlso listed as EHE12***E***A | 2.00 | Ducted, up to 1.5 tons | 63% | 216831958 |
| Capacity retention at 5°F | EPE30***DAlso listed as EPE30***E | 54% | Ducted, 2.5–3 tons | 24% | 218036118 |
| HSPF2 | 30WHHPBA | 6.8 | Ducted, 2.5–3 tons | 16% | 216831933 |
| SEER2 | 18WHHPBA | 14.2 | Ducted, up to 1.5 tons | 20% | 216831931 |
| EER2 | 18WHHPBA | 12.5 | Ducted, up to 1.5 tons | 76% | 216831931 |
| Heating capacity at 5°F | EHE18***D***AAlso listed as EHE18***E***A | 8,000 Btu/h | Ducted, up to 1.5 tons | 38% | 216831959 |
First Co. size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 11 models qualify) | 25.1(50 is the typical model of its size class)18WHHPBAwith ducted air handler 37CLX(*,Q,W)11 of 11 models have all five ratings · AHRI 216831931 |
| Ducted, 2 tons | None on this board (0 of 7 models qualify) | 30.4(50 is the typical model of its size class)24WHHPBAwith ducted air handler 37CLX(*,Q,W)7 of 7 models have all five ratings · AHRI 216831932 |
| Ducted, 2.5–3 tons | None on this board (0 of 3 models qualify) | 20.0(50 is the typical model of its size class)30WHHPBAwith ducted air handler 37CLX(*,Q,W)3 of 3 models have all five ratings · AHRI 216831933 |
Newest First Co. certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| EHE24***E***BFirst Co. | 2 tons24,400 Btu/h · Ducted | 2.00 | 51% | 6.3 | 11.9 | None | 1 | 218368488 |
| EPE30***EFirst Co. | 2.5 tons28,000 Btu/h · Ducted | 1.90 | 54% | 6.3 | 11.9 | None | 1 | 218364953 |
| EPE24***EFirst Co. | 2 tons23,000 Btu/h · Ducted | 1.80 | 54% | 6.3 | 11.9 | None | 1 | 218364952 |
| EPE18***EFirst Co. | 1.5 tons18,000 Btu/h · Ducted | 1.60 | 41% | 6.3 | 11.9 | None | 1 | 218364951 |
| EPE12***EFirst Co. | 1 ton11,200 Btu/h · Ducted | 1.60 | 40% | 6.3 | 11.9 | None | 1 | 218364950 |