Skip to content

AXTELL vs CIAC heat pumps

Measured against models of the same size and duct type, CIAC scores higher on 4 of the 6 ratings. AXTELL has 3 outdoor models, CIAC has 3 outdoor models. AXTELL and CIAC have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AXTELL and CIAC on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CIAC scores higher on 4 of the 6 ratings.
  • AXTELL
  • CIAC
  • Other ranked manufacturers
AXTELLCIAC

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAXTELLCIAC
Efficiency index22%median —40%median —
COP at 5°F62%median 2.2283%median 2.13
Capacity retention at 5°F3%median 53%19%median 67%
HSPF24%median 8.212%median 8.0
SEER215%median 18.122%median 17.0
EER225% (higher)median 11.316% (higher)median 9.5
Heating capacity at 5°F22% (higher)median 9,500 Btu/h18% (higher)median 6,700 Btu/h
Outdoor models33
AHRI certifications34

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAXTELLCIAC
CEE 2025 Tier 1 (Split ASHP)66.7%2 models33.3%1 models
CEE 2026 Tier 1 (Split ASHP)66.7%2 models33.3%1 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 1 groups where both have models
  • AXTELL
  • CIAC
  • All models of the group
Non-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAXTELLCIAC
Non-ducted, up to 1.5 tons2 · index 18%1 · index 40%
Non-ducted, 2 tons1 · index 28%None
Non-ducted, 2.5 to 3 tonsNone2 · index —

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAXTELLCold-climate score, best modelCIACCold-climate score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAXTELLAll-around score, best modelCIACAll-around score, best model
Non-ducted, up to 1.5 tons29.8(50 is the typical model of its size class)AT-INV18HM2A-Owith ductless indoor unit AT-INV18HM2A-I/AT-INV18HM2A-O2 of 2 models have all five ratings · AHRI 21804361239.8(50 is the typical model of its size class) (higher)CPEA12AC1151AOwith ductless indoor unit CPEA12AC1151AH1 of 1 models have all five ratings · AHRI 218814656
Non-ducted, 2 tons28.1(50 is the typical model of its size class)AT-INV24HM2A-Owith ductless indoor unit AT-INV24HM2A-I/AT-INV24HM2A-O1 of 1 models have all five ratings · AHRI 218043613No models in this size class
Non-ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 2 models have all five ratings)

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAXTELLCIAC
COP at 5°Fbeats 89% · 2.22AT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 95% · 2.21PCG817A-X036PHB3CNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 4% · 55%AT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 19% · 67%CPEA12AC1151AONon-ducted, up to 1.5 tons
HSPF2beats 4% · 8.2AT-INV12HM1A-ONon-ducted, up to 1.5 tonsbeats 30% · 9.0CPEA12AC1151AONon-ducted, up to 1.5 tons
SEER2beats 16% · 18.1AT-INV12HM1A-ONon-ducted, up to 1.5 tonsbeats 59% · 22.0CPEA12AC1151AONon-ducted, up to 1.5 tons
EER2beats 39% · 11.6AT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 18% · 10.0CPEA12AC1151AONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 54% · 9,500 Btu/hAT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 33% · 8,200 Btu/hCPEA12AC1151AONon-ducted, up to 1.5 tons

More comparisons