Skip to content

Bluefin vs NORTHCO CLIMAT.CA heat pumps

Measured against models of the same size and duct type, NORTHCO CLIMAT.CA scores higher on 5 of the 6 ratings. Bluefin has 7 outdoor models, NORTHCO CLIMAT.CA has 7 outdoor models. Bluefin and NORTHCO CLIMAT.CA have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Bluefin and NORTHCO CLIMAT.CA on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, NORTHCO CLIMAT.CA scores higher on 5 of the 6 ratings.
  • Bluefin
  • NORTHCO CLIMAT.CA
  • Other ranked manufacturers
BluefinNORTHCO …

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBluefinNORTHCO CLIMAT.CA
Efficiency index43%median —68%median —
COP at 5°F51% (higher)median 1.9928% (higher)median 1.80
Capacity retention at 5°F26%median 67%72%median 99%
HSPF237%median 9.174%median 10.0
SEER253%median 21.381%median 23.5
EER243%median 11.574%median 13.0
Heating capacity at 5°F39%median 17,000 Btu/h73%median 12,000 Btu/h
Outdoor models77
AHRI certifications97

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBluefinNORTHCO CLIMAT.CA
CEE 2025 Tier 1 (Split ASHP)71.4%5 models100%7 models
CEE 2026 Tier 1 (Split ASHP)71.4%5 models100%7 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)42.9%3 models100%7 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate42.9%3 models71.4%5 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 1 groups where both have models
  • Bluefin
  • NORTHCO CLIMAT.CA
  • All models of the group
Ducted, 2 tons2.001,155 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBluefinNORTHCO CLIMAT.CA
Ducted, 2 tons1 · index 65%None
Non-ducted, up to 1.5 tons3 · index 40%7 · index 68%
Non-ducted, 2 tons2 · index 45%None
Non-ducted, 2.5 to 3 tons2 · index 34%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBluefinCold-climate score, best modelNORTHCO CLIMAT.CACold-climate score, best model
Ducted, 2 tons48.1(50 is the typical model of its size class)BFMS27MZPL-02O1 of 1 models qualify · AHRI 216719248No models in this size class
Non-ducted, up to 1.5 tons41.2(50 is the typical model of its size class)BFMS09BA-02Owith ductless indoor unit BFMS09BA-02I1 of 3 models qualify · AHRI 21671924663.4(50 is the typical model of its size class) (higher)TSH12-NCC-HEI2NAP0T24Uwith ductless indoor unit TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGC7 of 7 models qualify · AHRI 218076232
Non-ducted, 2 tons47.2(50 is the typical model of its size class)BFMS24BA-02Owith ductless indoor unit BFMS24BA-02I2 of 2 models qualify · AHRI 216719243No models in this size class
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 2 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBluefinAll-around score, best modelNORTHCO CLIMAT.CAAll-around score, best model
Ducted, 2 tons64.6(50 is the typical model of its size class)BFMS27MZPL-02O1 of 1 models have all five ratings · AHRI 216719248No models in this size class
Non-ducted, up to 1.5 tons51.4(50 is the typical model of its size class)BFMS09BA-02Owith ductless indoor unit BFMS09BA-02I3 of 3 models have all five ratings · AHRI 21671924675.6(50 is the typical model of its size class) (higher)TSH12-NCC-HEI2NAP0T24Uwith ductless indoor unit TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGC7 of 7 models have all five ratings · AHRI 218076232
Non-ducted, 2 tons59.0(50 is the typical model of its size class)BFMS27MZPL-02O2 of 2 models have all five ratings · AHRI 216719247No models in this size class
Non-ducted, 2.5 to 3 tons40.7(50 is the typical model of its size class)BFMS30BA-02Owith ductless indoor unit BFMS30BA-02I2 of 2 models have all five ratings · AHRI 216719244No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBluefinNORTHCO CLIMAT.CA
COP at 5°Fbeats 76% · 2.11BFMS24BA-02ONon-ducted, 2 tonsbeats 78% · 2.10TSC-NCC454-12HA1/I3TI22Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 41% · 71%BFMS24BA-02ONon-ducted, 2 tonsbeats 88% · 100%TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
HSPF2beats 53% · 9.0BFMS27MZPL-02ODucted, 2 tonsbeats 81% · 10.5TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
SEER2beats 94% · 21.0BFMS27MZPL-02ODucted, 2 tonsbeats 85% · 25.0TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
EER2beats 65% · 12.6BFMS09BA-02ONon-ducted, up to 1.5 tonsbeats 85% · 14.0TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 65% · 11,500 Btu/hBFMS18BA-02ONon-ducted, up to 1.5 tonsbeats 91% · 17,800 Btu/hTSH18-NCC-HEI2NAN5T24UAlso listed as NCC-H18SUH23XGCNon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter