Skip to content

Badger manufacture vs NORTHCO CLIMAT.CA heat pumps

Measured against models of the same size and duct type, NORTHCO CLIMAT.CA scores higher on 3 of the 6 ratings. Badger manufacture has 7 outdoor models, NORTHCO CLIMAT.CA has 7 outdoor models. Badger manufacture and NORTHCO CLIMAT.CA have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Badger manufacture and NORTHCO CLIMAT.CA on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, NORTHCO CLIMAT.CA scores higher on 3 of the 6 ratings.
  • Badger manufacture
  • NORTHCO CLIMAT.CA
  • Other ranked manufacturers
Badger m…NORTHCO …

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBadger manufactureNORTHCO CLIMAT.CA
Efficiency index—median —68%median —
COP at 5°F—median —28%median 1.80
Capacity retention at 5°F—median —72%median 99%
HSPF225%median 7.574%median 10.0
SEER220%median 14.381%median 23.5
EER260%median 11.774%median 13.0
Heating capacity at 5°F—median —73%median 12,000 Btu/h
Outdoor models77
AHRI certifications117

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBadger manufactureNORTHCO CLIMAT.CA
CEE 2025 Tier 1 (Split ASHP)0%0 models100%7 models
CEE 2026 Tier 1 (Split ASHP)0%0 models100%7 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models100%7 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models71.4%5 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 0 groups where both have models
  • Badger manufacture
  • NORTHCO CLIMAT.CA
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBadger manufactureNORTHCO CLIMAT.CA
Ducted, up to 1.5 tons1 · index —None
Ducted, 2 tons2 · index —None
Ducted, 2.5 to 3 tons2 · index —None
Ducted, 3.5 to 4.5 tons2 · index —None
Non-ducted, up to 1.5 tonsNone7 · index 68%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBadger manufactureCold-climate score, best modelNORTHCO CLIMAT.CACold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)No models in this size class
Ducted, 2 tonsNone on this board (0 of 2 models qualify)No models in this size class
Ducted, 2.5 to 3 tonsNone on this board (0 of 2 models qualify)No models in this size class
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class63.4(50 is the typical model of its size class)TSH12-NCC-HEI2NAP0T24Uwith ductless indoor unit TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGC7 of 7 models qualify · AHRI 218076232

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBadger manufactureAll-around score, best modelNORTHCO CLIMAT.CAAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Ducted, 2 tonsNone on this board (0 of 2 models have all five ratings)No models in this size class
Ducted, 2.5 to 3 tonsNone on this board (0 of 2 models have all five ratings)No models in this size class
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models have all five ratings)No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class75.6(50 is the typical model of its size class)TSH12-NCC-HEI2NAP0T24Uwith ductless indoor unit TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGC7 of 7 models have all five ratings · AHRI 218076232

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBadger manufactureNORTHCO CLIMAT.CA
COP at 5°F—beats 78% · 2.10TSC-NCC454-12HA1/I3TI22Non-ducted, up to 1.5 tons
Capacity retention at 5°F—beats 88% · 100%TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
HSPF2beats 27% · 7.5DHP5048E1000BDucted, 3.5 to 4.5 tonsbeats 81% · 10.5TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
SEER2beats 22% · 14.3DHP5048E1000BDucted, 3.5 to 4.5 tonsbeats 85% · 25.0TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
EER2beats 69% · 11.7DHP5048E1000BDucted, 3.5 to 4.5 tonsbeats 85% · 14.0TSH12-NCC-HEI2NAP0T24UAlso listed as TSH12-NCC-HEI2NAPOT24U, NCC-H12SUH23XGCNon-ducted, up to 1.5 tons
Heating capacity at 5°F—beats 91% · 17,800 Btu/hTSH18-NCC-HEI2NAN5T24UAlso listed as NCC-H18SUH23XGCNon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter