Skip to content

BRAVO vs Enerwave heat pumps

Measured against models of the same size and duct type, BRAVO scores higher on 6 of the 6 ratings. BRAVO has 14 outdoor models, Enerwave has 14 outdoor models. BRAVO and Enerwave have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BRAVO and Enerwave on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BRAVO scores higher on 6 of the 6 ratings.
  • BRAVO
  • Enerwave
  • Other ranked manufacturers
BRAVOEnerwave

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBRAVOEnerwave
Efficiency index47% (higher)median —22% (higher)median —
COP at 5°F48% (higher)median 1.9017% (higher)median 1.71
Capacity retention at 5°F41% (higher)median 70%31% (higher)median 72%
HSPF253% (higher)median 9.536% (higher)median 9.2
SEER251% (higher)median 19.518% (higher)median 13.9
EER244% (higher)median 10.815% (higher)median 10.6
Heating capacity at 5°F41% (higher)median 13,250 Btu/h10% (higher)median 5,900 Btu/h
Outdoor models1414
AHRI certifications2814

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBRAVOEnerwave
CEE 2025 Tier 1 (Split ASHP)57.1%8 models0%0 models
CEE 2026 Tier 1 (Split ASHP)57.1%8 models0%0 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)57.1%8 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate21.4%3 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 1 groups where both have models
  • BRAVO
  • Enerwave
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBRAVOEnerwave
Ducted, up to 1.5 tons1 · index 61%14 · index 22%
Ducted, 2 tons1 · index 66%None
Ducted, 2.5–3 tons2 · index 76%None
Ducted, 3.5–4.5 tons1 · index 87%None
Non-ducted, up to 1.5 tons7 · index 32%None
Non-ducted, 2 tons3 · index 38%None
Non-ducted, 2.5–3 tons3 · index 41%None
Non-ducted, 3.5–4.5 tons1 · index 74%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBRAVOCold-climate score, best modelEnerwaveCold-climate score, best model
Ducted, up to 1.5 tons55.6(50 is the typical model of its size class) (higher)BRV-M18-230VO1 of 1 models qualify · AHRI 21722145743.8(50 is the typical model of its size class)VD3SD18EWAlso listed as VD3SD27EW12 of 14 models qualify · AHRI 218418644
Ducted, 2 tons59.1(50 is the typical model of its size class)BRV-M24-230VO1 of 1 models qualify · AHRI 217221458No models in this size class
Ducted, 2.5–3 tons73.8(50 is the typical model of its size class)BRV-M30-230VO2 of 2 models qualify · AHRI 217221459No models in this size class
Ducted, 3.5–4.5 tons76.8(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models qualify · AHRI 217221461No models in this size class
Non-ducted, up to 1.5 tons64.5(50 is the typical model of its size class)BRV-M18-230VO3 of 7 models qualify · AHRI 217221452No models in this size class
Non-ducted, 2 tons67.5(50 is the typical model of its size class)BRV-M24-230VO2 of 3 models qualify · AHRI 217221453No models in this size class
Non-ducted, 2.5–3 tons62.1(50 is the typical model of its size class)BRV-M30-230VO2 of 3 models qualify · AHRI 217221464No models in this size class
Non-ducted, 3.5–4.5 tons59.9(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models qualify · AHRI 217221466No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBRAVOAll-around score, best modelEnerwaveAll-around score, best model
Ducted, up to 1.5 tons61.1(50 is the typical model of its size class) (higher)BRV-M18-230VO1 of 1 models have all five ratings · AHRI 21722145746.5(50 is the typical model of its size class)W2SH06AEW14 of 14 models have all five ratings · AHRI 218418648
Ducted, 2 tons66.1(50 is the typical model of its size class)BRV-M24-230VO1 of 1 models have all five ratings · AHRI 217221458No models in this size class
Ducted, 2.5–3 tons80.7(50 is the typical model of its size class)BRV-M30-230VO2 of 2 models have all five ratings · AHRI 217221459No models in this size class
Ducted, 3.5–4.5 tons87.0(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models have all five ratings · AHRI 217221461No models in this size class
Non-ducted, up to 1.5 tons61.4(50 is the typical model of its size class)BRV-P09LS-230VOwith ductless indoor unit BRV-P09CT-230VI7 of 7 models have all five ratings · AHRI 218425279No models in this size class
Non-ducted, 2 tons71.8(50 is the typical model of its size class)BRV-M24-230VO3 of 3 models have all five ratings · AHRI 217221453No models in this size class
Non-ducted, 2.5–3 tons66.6(50 is the typical model of its size class)BRV-M30-230VO3 of 3 models have all five ratings · AHRI 217221454No models in this size class
Non-ducted, 3.5–4.5 tons74.4(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models have all five ratings · AHRI 217221466No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBRAVOEnerwave
COP at 5°Fbeats 83% · 2.05BRV-M30-230VONon-ducted, 2.5–3 tonsbeats 79% · 2.16W2SH06AEWDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 79% · 90%BRV-M24-230VONon-ducted, 2 tonsbeats 44% · 73%VD3SD18EWAlso listed as VD3SD27EWDucted, up to 1.5 tons
HSPF2beats 86% · 10.0BRV-M42-230VODucted, 3.5–4.5 tonsbeats 97% · 12.6W2SH06AEWDucted, up to 1.5 tons
SEER2beats 100% · 22.0BRV-M42-230VODucted, 3.5–4.5 tonsbeats 46% · 15.8W3PHEF8BEWDucted, up to 1.5 tons
EER2beats 91% · 12.3BRV-M42-230VODucted, 3.5–4.5 tonsbeats 31% · 11.2W3PHEF8BEWDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 85% · 14,500 Btu/hBRV-M18-230VONon-ducted, up to 1.5 tonsbeats 22% · 6,500 Btu/hVD3SD18EWAlso listed as VD3SD27EWDucted, up to 1.5 tons

More comparisons