Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Enerwave vs HAVELLS heat pumps
Measured against models of the same size and duct type, HAVELLS scores higher on 6 of the 6 ratings. Enerwave has 14 outdoor models, HAVELLS has 14 outdoor models. Enerwave and HAVELLS have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Enerwave
- HAVELLS
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Enerwave | HAVELLS |
|---|---|---|
| Efficiency index | 22%median — | 57%median — |
| COP at 5°F | 17%median 1.71 | 43%median 1.90 |
| Capacity retention at 5°F | 31%median 72% | 69%median 87% |
| HSPF2 | 36%median 9.2 | 62%median 9.7 |
| SEER2 | 18%median 13.9 | 70%median 22.0 |
| EER2 | 15%median 10.6 | 44%median 12.0 |
| Heating capacity at 5°F | 10%median 5,900 Btu/h | 72%median 23,000 Btu/h |
| Outdoor models | 14 | 14 |
| AHRI certifications | 14 | 14 |
Share of models meeting each standard
| Standard | Enerwave | HAVELLS |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 92.9%13 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 92.9%13 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 85.7%12 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 85.7%12 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Enerwave
- HAVELLS
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Enerwave | HAVELLS |
|---|---|---|
| Ducted, up to 1.5 tons | 14 · index 22% | 1 · index 56% |
| Ducted, 2 tons | None | 1 · index 56% |
| Ducted, 2.5–3 tons | None | 2 · index 58% |
| Ducted, 3.5–4.5 tons | None | 2 · index 57% |
| Non-ducted, up to 1.5 tons | None | 5 · index 54% |
| Non-ducted, 2 tons | None | 1 · index 72% |
| Non-ducted, 2.5–3 tons | None | 2 · index 60% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EnerwaveCold-climate score, best model | HAVELLSCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 43.8(50 is the typical model of its size class)VD3SD18EWAlso listed as VD3SD27EW12 of 14 models qualify · AHRI 218418644 | 53.8(50 is the typical model of its size class) (higher)GHO18H52ACXL05with ducted air handler GHA18H52ACXL051 of 1 models qualify · AHRI 218045459 |
| Ducted, 2 tons | No models in this size class | 59.5(50 is the typical model of its size class)GHO24H52ACXL05with ducted air handler GHA24H52ACXL051 of 1 models qualify · AHRI 218045460 |
| Ducted, 2.5–3 tons | No models in this size class | 69.4(50 is the typical model of its size class)GHO36H52ACXL05with ducted air handler GHA36H52ACXL052 of 2 models qualify · AHRI 218045462 |
| Ducted, 3.5–4.5 tons | No models in this size class | 74.9(50 is the typical model of its size class)GHO48H52ACXL05with ducted air handler GHA48H52ACXL052 of 2 models qualify · AHRI 218045463 |
| Non-ducted, up to 1.5 tons | No models in this size class | 64.5(50 is the typical model of its size class)GSSHAX76414 of 5 models qualify · AHRI 215588561 |
| Non-ducted, 2 tons | No models in this size class | 67.5(50 is the typical model of its size class)GSSHAX76421 of 1 models qualify · AHRI 215588562 |
| Non-ducted, 2.5–3 tons | No models in this size class | 58.8(50 is the typical model of its size class)GSSHAX76442 of 2 models qualify · AHRI 215864436 |
All-around best
| Size and duct type | EnerwaveAll-around score, best model | HAVELLSAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 46.5(50 is the typical model of its size class)W2SH06AEW14 of 14 models have all five ratings · AHRI 218418648 | 55.8(50 is the typical model of its size class) (higher)GHO18H52ACXL05with ducted air handler GHA18H52ACXL051 of 1 models have all five ratings · AHRI 218045459 |
| Ducted, 2 tons | No models in this size class | 55.5(50 is the typical model of its size class)GHO24H52ACXL05with ducted air handler GHA24H52ACXL051 of 1 models have all five ratings · AHRI 218045460 |
| Ducted, 2.5–3 tons | No models in this size class | 60.1(50 is the typical model of its size class)GHO30H52ACXL05with ducted air handler GHA30H52ACXL052 of 2 models have all five ratings · AHRI 218045461 |
| Ducted, 3.5–4.5 tons | No models in this size class | 59.2(50 is the typical model of its size class)GHO48H52ACXL05with ducted air handler GHA48H52ACXL052 of 2 models have all five ratings · AHRI 218045463 |
| Non-ducted, up to 1.5 tons | No models in this size class | 61.2(50 is the typical model of its size class)GHS09H5MWAHD05with ductless indoor unit GHS09H5MWAHD055 of 5 models have all five ratings · AHRI 218431857 |
| Non-ducted, 2 tons | No models in this size class | 71.8(50 is the typical model of its size class)GSSHAX76421 of 1 models have all five ratings · AHRI 215588562 |
| Non-ducted, 2.5–3 tons | No models in this size class | 62.6(50 is the typical model of its size class)GSSHAX76432 of 2 models have all five ratings · AHRI 215588563 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Enerwave | HAVELLS |
|---|---|---|
| COP at 5°F | beats 79% · 2.16W2SH06AEWDucted, up to 1.5 tons | beats 63% · 2.00GSSHAX7641Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 44% · 73%VD3SD18EWAlso listed as VD3SD27EWDucted, up to 1.5 tons | beats 91% · 100%GHO18H52ACXL05Ducted, up to 1.5 tons |
| HSPF2 | beats 97% · 12.6W2SH06AEWDucted, up to 1.5 tons | beats 84% · 10.0GHO36H52ACXL05Ducted, 2.5–3 tons |
| SEER2 | beats 46% · 15.8W3PHEF8BEWDucted, up to 1.5 tons | beats 84% · 25.0GHS09H5MWAHD05Non-ducted, up to 1.5 tons |
| EER2 | beats 31% · 11.2W3PHEF8BEWDucted, up to 1.5 tons | beats 71% · 12.3GSSHAX7643Non-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 22% · 6,500 Btu/hVD3SD18EWAlso listed as VD3SD27EWDucted, up to 1.5 tons | beats 99% · 22,000 Btu/hGHO18H52ACXL05Ducted, up to 1.5 tons |