Skip to content

Everwell vs HAVELLS heat pumps

Measured against models of the same size and duct type, HAVELLS scores higher on 6 of the 6 ratings. Everwell has 19 outdoor models, HAVELLS has 18 outdoor models. Everwell and HAVELLS have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Everwell and HAVELLS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, HAVELLS scores higher on 6 of the 6 ratings.
  • Everwell
  • HAVELLS
  • Other ranked manufacturers
EverwellHAVELLS

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingEverwellHAVELLS
Efficiency index28%median —57%median —
COP at 5°F40%median 1.9546%median 1.90
Capacity retention at 5°F20%median 54%63%median 79%
HSPF221%median 8.060%median 9.6
SEER221%median 17.068%median 22.3
EER227%median 9.847%median 12.0
Heating capacity at 5°F28%median 10,800 Btu/h64%median 21,000 Btu/h
Outdoor models1918
AHRI certifications4418

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardEverwellHAVELLS
CEE 2025 Tier 1 (Split ASHP)10.5%2 models88.9%16 models
CEE 2026 Tier 1 (Split ASHP)10.5%2 models88.9%16 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)10.5%2 models83.3%15 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models66.7%12 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • Everwell
  • HAVELLS
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeEverwellHAVELLS
Ducted, up to 1.5 tons1 · index 26%1 · index 57%
Ducted, 2 tons1 · index 26%1 · index 56%
Ducted, 2.5 to 3 tons4 · index 44%2 · index 58%
Ducted, 3.5 to 4.5 tons3 · index —2 · index 57%
Non-ducted, up to 1.5 tons6 · index 14%7 · index 58%
Non-ducted, 2 tons2 · index —2 · index 62%
Non-ducted, 2.5 to 3 tons2 · index 8%3 · index 48%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeEverwellCold-climate score, best modelHAVELLSCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)54.9(50 is the typical model of its size class)GHO18H52ACXL05with ducted air handler GHA18H52ACXL051 of 1 models qualify · AHRI 218045459
Ducted, 2 tonsNone on this board (0 of 1 models qualify)59.5(50 is the typical model of its size class)GHO24H52ACXL05with ducted air handler GHA24H52ACXL051 of 1 models qualify · AHRI 218045460
Ducted, 2.5 to 3 tons57.1(50 is the typical model of its size class)EPKH03625HA-18Also listed as EPKH03625HA-182 of 4 models qualify · AHRI 21750897769.4(50 is the typical model of its size class) (higher)GHO36H52ACXL05with ducted air handler GHA36H52ACXL052 of 2 models qualify · AHRI 218045462
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 3 models qualify)74.7(50 is the typical model of its size class)GHO48H52ACXL05with ducted air handler GHA48H52ACXL052 of 2 models qualify · AHRI 218045463
Non-ducted, up to 1.5 tonsNone on this board (0 of 6 models qualify)66.1(50 is the typical model of its size class)GSSHAX76416 of 7 models qualify · AHRI 215588561
Non-ducted, 2 tonsNone on this board (0 of 2 models qualify)68.5(50 is the typical model of its size class)GSSHAX76422 of 2 models qualify · AHRI 215588562
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 2 models qualify)59.7(50 is the typical model of its size class)GSSHAX76442 of 3 models qualify · AHRI 215864436

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeEverwellAll-around score, best modelHAVELLSAll-around score, best model
Ducted, up to 1.5 tons25.9(50 is the typical model of its size class)CAC1814HA15with ducted air handler 26UCS(*,E,Q,R,W)*X1 of 1 models have all five ratings · AHRI 21814798057.4(50 is the typical model of its size class) (higher)GHO18H52ACXL05with ducted air handler GHA18H52ACXL051 of 1 models have all five ratings · AHRI 218045459
Ducted, 2 tons26.3(50 is the typical model of its size class)CAC2414HA15with ducted air handler 26UCS(*,E,Q,R,W)*X1 of 1 models have all five ratings · AHRI 21814798955.5(50 is the typical model of its size class) (higher)GHO24H52ACXL05with ducted air handler GHA24H52ACXL051 of 1 models have all five ratings · AHRI 218045460
Ducted, 2.5 to 3 tons53.1(50 is the typical model of its size class)EPKH03625HA-18Also listed as EPKH03625HA-184 of 4 models have all five ratings · AHRI 21750897760.7(50 is the typical model of its size class) (higher)GHO30H52ACXL05with ducted air handler GHA30H52ACXL052 of 2 models have all five ratings · AHRI 218045461
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 3 models have all five ratings)59.4(50 is the typical model of its size class)GHO48H52ACXL05with ducted air handler GHA48H52ACXL052 of 2 models have all five ratings · AHRI 218045463
Non-ducted, up to 1.5 tons23.3(50 is the typical model of its size class)MKTH1215C-17with ductless indoor unit MKTH1215E-173 of 6 models have all five ratings · AHRI 21750026166.9(50 is the typical model of its size class) (higher)GHO12Z5TWAHD05with ductless indoor unit GHI12Z5TWAHD057 of 7 models have all five ratings · AHRI 218088500
Non-ducted, 2 tonsNone on this board (0 of 2 models have all five ratings)73.3(50 is the typical model of its size class)GSSHAX76422 of 2 models have all five ratings · AHRI 215588562
Non-ducted, 2.5 to 3 tons8.0(50 is the typical model of its size class)MKTH3625C-17*with ductless indoor unit MKTH3625E-171 of 2 models have all five ratings · AHRI 21773005763.4(50 is the typical model of its size class) (higher)GSSHAX76433 of 3 models have all five ratings · AHRI 215588563

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingEverwellHAVELLS
COP at 5°Fbeats 57% · 2.00EPKH03625HA-18Also listed as EPKH03625HA-18Ducted, 2.5 to 3 tonsbeats 80% · 2.03GHO36Z5TWAHD05Non-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 56% · 73%EPKH03625HA-18Also listed as EPKH03625HA-18Ducted, 2.5 to 3 tonsbeats 92% · 100%GHO18H52ACXL05Ducted, up to 1.5 tons
HSPF2beats 53% · 8.5EPKH03625HA-18Also listed as EPKH03625HA-18Ducted, 2.5 to 3 tonsbeats 84% · 10.0GHO36H52ACXL05Ducted, 2.5 to 3 tons
SEER2beats 74% · 18.5EPKH03625HA-18Also listed as EPKH03625HA-18Ducted, 2.5 to 3 tonsbeats 85% · 25.0GHS09H5MWAHD05Non-ducted, up to 1.5 tons
EER2beats 56% · 11.4CAC4214HA15Ducted, 3.5 to 4.5 tonsbeats 73% · 13.0GHO09Z5TWAHD05Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 62% · 26,400 Btu/hEPKH03625HA-18Also listed as EPKH03625HA-18Ducted, 2.5 to 3 tonsbeats 99% · 22,000 Btu/hGHO18H52ACXL05Ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter