Skip to content

Clima Smart vs Live cool heat pumps

Measured against models of the same size and duct type, Clima Smart scores higher on 5 of the 6 ratings. Clima Smart has 10 outdoor models, Live cool has 10 outdoor models. Clima Smart and Live cool have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Clima Smart and Live cool on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Clima Smart scores higher on 5 of the 6 ratings.
  • Clima Smart
  • Live cool
  • Other ranked manufacturers
Clima Sm…Live cool

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingClima SmartLive cool
Efficiency index75% (higher)median —59% (higher)median —
COP at 5°F37%median 1.9045%median 1.84
Capacity retention at 5°F82% (higher)median 98%40% (higher)median 72%
HSPF268% (higher)median 10.060% (higher)median 10.0
SEER292% (higher)median 25.076% (higher)median 23.0
EER284% (higher)median 13.866% (higher)median 13.0
Heating capacity at 5°F75% (higher)median 21,100 Btu/h49% (higher)median 9,100 Btu/h
Outdoor models1010
AHRI certifications1310

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardClima SmartLive cool
CEE 2025 Tier 1 (Split ASHP)100%10 models100%10 models
CEE 2026 Tier 1 (Split ASHP)100%10 models100%10 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)100%10 models100%10 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate80%8 models90%9 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • Clima Smart
  • Live cool
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2.5 to 3 tons2.002,055 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeClima SmartLive cool
Ducted, up to 1.5 tons1 · index 73%None
Ducted, 2.5 to 3 tons1 · index 80%None
Non-ducted, up to 1.5 tons5 · index 77%8 · index 61%
Non-ducted, 2 tons1 · index 59%2 · index 51%
Non-ducted, 2.5 to 3 tons2 · index 80%None
Non-ducted, 3.5 to 4.5 tons1 · index 70%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeClima SmartCold-climate score, best modelLive coolCold-climate score, best model
Ducted, up to 1.5 tons56.0(50 is the typical model of its size class)MU-CSU18HEI2NAM0T24-3PO1 of 1 models qualify · AHRI 218858070No models in this size class
Ducted, 2.5 to 3 tons63.0(50 is the typical model of its size class)MU-CSU27HEI2NAMOT24-4PO1 of 1 models qualify · AHRI 218858071No models in this size class
Non-ducted, up to 1.5 tons72.4(50 is the typical model of its size class) (higher)MU-CSU18HEI2NAM0T24-3POAlso listed as CSU06HEI2NAM0T245 of 5 models qualify · AHRI 21804480761.2(50 is the typical model of its size class)KWSM-12IR454BHS24Rwith ductless indoor unit LWSM-12IR454BHS24RAlso listed as LWSM-12IR454BHS24R8 of 8 models qualify · AHRI 217617840
Non-ducted, 2 tons59.1(50 is the typical model of its size class) (higher)CSU24HEI2NAK0T24with ductless indoor unit CSU24HEI2NAK0T241 of 1 models qualify · AHRI 21804376139.6(50 is the typical model of its size class)KWSM-24IR454BHS23Rwith ductless indoor unit LWSM-24IR454BHS23RAlso listed as LWSM-24IR454BHS23R2 of 2 models qualify · AHRI 217617842
Non-ducted, 2.5 to 3 tons68.7(50 is the typical model of its size class)MU-CSU27HEI2NAM0T24-4PO2 of 2 models qualify · AHRI 218044808No models in this size class
Non-ducted, 3.5 to 4.5 tons48.5(50 is the typical model of its size class)MU-CSU48HEI2NAM0T24-6PO1 of 1 models qualify · AHRI 218044810No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeClima SmartAll-around score, best modelLive coolAll-around score, best model
Ducted, up to 1.5 tons73.3(50 is the typical model of its size class)MU-CSU18HEI2NAM0T24-3PO1 of 1 models have all five ratings · AHRI 218858070No models in this size class
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class)MU-CSU27HEI2NAMOT24-4PO1 of 1 models have all five ratings · AHRI 218858071No models in this size class
Non-ducted, up to 1.5 tons83.7(50 is the typical model of its size class) (higher)MU-CSU18HEI2NAM0T24-3POAlso listed as CSU06HEI2NAM0T245 of 5 models have all five ratings · AHRI 21804480769.5(50 is the typical model of its size class)KWSM-12IR454BHS24Rwith ductless indoor unit LWSM-12IR454BHS24RAlso listed as LWSM-12IR454BHS24R8 of 8 models have all five ratings · AHRI 217617840
Non-ducted, 2 tons58.5(50 is the typical model of its size class) (higher)CSU24HEI2NAK0T24with ductless indoor unit CSU24HEI2NAK0T241 of 1 models have all five ratings · AHRI 21804376151.4(50 is the typical model of its size class)KWSM-24IR454BHS23Rwith ductless indoor unit LWSM-24IR454BHS23RAlso listed as LWSM-24IR454BHS23R2 of 2 models have all five ratings · AHRI 217617842
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class)MU-CSU27HEI2NAM0T24-4PO2 of 2 models have all five ratings · AHRI 218044808No models in this size class
Non-ducted, 3.5 to 4.5 tons70.2(50 is the typical model of its size class)MU-CSU48HEI2NAM0T24-6PO1 of 1 models have all five ratings · AHRI 218044810No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingClima SmartLive cool
COP at 5°Fbeats 64% · 2.00MU-CSU18HEI2NAM0T24-3POAlso listed as CSU06HEI2NAM0T24Non-ducted, up to 1.5 tonsbeats 78% · 2.10KWSM-12IR454BHS23LRAlso listed as LWSM-12IR454BHS23LRNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 96% · 105%MU-CSU18HEI2NAM0T24-3PODucted, up to 1.5 tonsbeats 56% · 76%KWSM-24IR454BHS23RAlso listed as LWSM-24IR454BHS23RNon-ducted, 2 tons
HSPF2beats 96% · 10.5MU-CSU27HEI2NAMOT24-4PODucted, 2.5 to 3 tonsbeats 66% · 10.0KWSM-12IR454BHS23LRAlso listed as LWSM-12IR454BHS23LRNon-ducted, up to 1.5 tons
SEER2beats 100% · 22.0MU-CSU27HEI2NAMOT24-4PODucted, 2.5 to 3 tonsbeats 81% · 23.0KWSM-24IR454BHS23RAlso listed as LWSM-24IR454BHS23RNon-ducted, 2 tons
EER2beats 97% · 14.0MU-CSU27HEI2NAM0T24-4PONon-ducted, 2.5 to 3 tonsbeats 73% · 13.0KWSM-12IR454BHS23LRAlso listed as LWSM-12IR454BHS23LRNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 19,800 Btu/hMU-CSU18HEI2NAM0T24-3POAlso listed as CSU06HEI2NAM0T24Non-ducted, up to 1.5 tonsbeats 80% · 13,600 Btu/hKWSM-18IR454BHS23RAlso listed as LWSM-18IR454BHS23RNon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter