Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DUCTLESSAIRE vs TURBRO heat pumps
Measured against models of the same size and duct type, DUCTLESSAIRE scores higher on 2 of the 6 ratings. DUCTLESSAIRE has 16 outdoor models, TURBRO has 24 outdoor models. DUCTLESSAIRE and TURBRO have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- DUCTLESSAIRE
- TURBRO
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | DUCTLESSAIRE | TURBRO |
|---|---|---|
| Efficiency index | 54%median — | 55%median — |
| COP at 5°F | 64%median 2.10 | 64%median 2.08 |
| Capacity retention at 5°F | 37%median 71% | 42%median 72% |
| HSPF2 | 57% (higher)median 9.5 | 52% (higher)median 10.0 |
| SEER2 | 62%median 21.2 | 62%median 23.0 |
| EER2 | 50% (higher)median 12.0 | 47% (higher)median 12.0 |
| Heating capacity at 5°F | 45%median 12,950 Btu/h | 45%median 13,600 Btu/h |
| Outdoor models | 16 | 24 |
| AHRI certifications | 24 | 34 |
Share of models meeting each standard
| Standard | DUCTLESSAIRE | TURBRO |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 81.3%13 models | 79.2%19 models |
| CEE 2026 Tier 1 (Split ASHP) | 81.3%13 models | 79.2%19 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75%12 models | 83.3%20 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 62.5%10 models | 58.3%14 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- DUCTLESSAIRE
- TURBRO
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | DUCTLESSAIRE | TURBRO |
|---|---|---|
| Ducted, 2 tons | 2 · index 65% | None |
| Ducted, 2.5–3 tons | 1 · index 70% | None |
| Ducted, 3.5–4.5 tons | 1 · index 85% | None |
| Non-ducted, up to 1.5 tons | 9 · index 52% | 17 · index 57% |
| Non-ducted, 2 tons | 5 · index 45% | 4 · index 52% |
| Non-ducted, 2.5–3 tons | 1 · index 58% | 2 · index 58% |
| Non-ducted, 3.5–4.5 tons | 1 · index 51% | 1 · index 42% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | DUCTLESSAIRECold-climate score, best model | TURBROCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | 48.6(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O2 of 2 models qualify · AHRI 217232132 | No models in this size class |
| Ducted, 2.5–3 tons | 60.6(50 is the typical model of its size class)454-36-5Z-O1 of 1 models qualify · AHRI 217232141 | No models in this size class |
| Ducted, 3.5–4.5 tons | 77.9(50 is the typical model of its size class)454-48-6Z-O1 of 1 models qualify · AHRI 217232138 | No models in this size class |
| Non-ducted, up to 1.5 tons | 84.7(50 is the typical model of its size class) (higher)454-9-O-DAwith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA6 of 9 models qualify · AHRI 217232127 | 79.3(50 is the typical model of its size class)LAPLAND-18K-Owith ductless indoor unit LAPLAND-18K-IAlso listed as LL-18K-O14 of 17 models qualify · AHRI 218004383 |
| Non-ducted, 2 tons | 52.6(50 is the typical model of its size class)454-24-O-DAwith ductless indoor unit 454-24-I-DA4 of 5 models qualify · AHRI 217232130 | 77.5(50 is the typical model of its size class) (higher)LAPLAND-24K-Owith ductless indoor unit LAPLAND-24K-IAlso listed as LL-24K-O3 of 4 models qualify · AHRI 218004384 |
| Non-ducted, 2.5–3 tons | 47.2(50 is the typical model of its size class)454-36-5Z-O1 of 1 models qualify · AHRI 217232140 | 57.5(50 is the typical model of its size class) (higher)GREENLAND-M27K/O2 of 2 models qualify · AHRI 217222921 |
| Non-ducted, 3.5–4.5 tons | 60.1(50 is the typical model of its size class) (higher)454-48-6Z-O1 of 1 models qualify · AHRI 217232139 | 31.2(50 is the typical model of its size class)GREENLAND-M42K/O1 of 1 models qualify · AHRI 217222923 |
All-around best
| Size and duct type | DUCTLESSAIREAll-around score, best model | TURBROAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 64.5(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O2 of 2 models have all five ratings · AHRI 217232132 | No models in this size class |
| Ducted, 2.5–3 tons | 69.5(50 is the typical model of its size class)454-36-5Z-O1 of 1 models have all five ratings · AHRI 217232141 | No models in this size class |
| Ducted, 3.5–4.5 tons | 85.1(50 is the typical model of its size class)454-48-6Z-O1 of 1 models have all five ratings · AHRI 217232138 | No models in this size class |
| Non-ducted, up to 1.5 tons | 85.6(50 is the typical model of its size class) (higher)454-9-O-DAwith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA9 of 9 models have all five ratings · AHRI 217232127 | 83.0(50 is the typical model of its size class)LAPLAND-18K-Owith ductless indoor unit LAPLAND-18K-IAlso listed as LL-18K-O15 of 17 models have all five ratings · AHRI 218004383 |
| Non-ducted, 2 tons | 56.7(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O5 of 5 models have all five ratings · AHRI 217232131 | 68.1(50 is the typical model of its size class) (higher)LAPLAND-24K-Owith ductless indoor unit LAPLAND-24K-IAlso listed as LL-24K-O4 of 4 models have all five ratings · AHRI 218004384 |
| Non-ducted, 2.5–3 tons | 58.3(50 is the typical model of its size class)454-36-5Z-O1 of 1 models have all five ratings · AHRI 217232140 | 65.1(50 is the typical model of its size class) (higher)GREENLAND-M27K/O2 of 2 models have all five ratings · AHRI 217222921 |
| Non-ducted, 3.5–4.5 tons | 52.8(50 is the typical model of its size class) (higher)454-48-6Z-O1 of 1 models have all five ratings · AHRI 217232139 | 42.4(50 is the typical model of its size class)GREENLAND-M42K/O1 of 1 models have all five ratings · AHRI 217222923 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | DUCTLESSAIRE | TURBRO |
|---|---|---|
| COP at 5°F | beats 96% · 2.39454-18-O-DANon-ducted, up to 1.5 tons | beats 89% · 2.25LAPLAND-18K-OAlso listed as LL-18K-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 66% · 81%454-48-6Z-ODucted, 3.5–4.5 tons | beats 75% · 87%LAPLAND-24K-OAlso listed as LL-24K-ONon-ducted, 2 tons |
| HSPF2 | beats 96% · 13.0454-9-O-DAAlso listed as 454-09-O-DANon-ducted, up to 1.5 tons | beats 80% · 10.5GREENLAND-M27K/ONon-ducted, 2.5–3 tons |
| SEER2 | beats 96% · 20.4454-48-6Z-ODucted, 3.5–4.5 tons | beats 91% · 24.0GREENLAND-M27K/ONon-ducted, 2.5–3 tons |
| EER2 | beats 87% · 14.4454-9-O-DAAlso listed as 454-09-O-DANon-ducted, up to 1.5 tons | beats 83% · 14.0LAPLAND-18K-OAlso listed as LL-18K-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 76% · 13,400 Btu/h454-18-O-DANon-ducted, up to 1.5 tons | beats 88% · 16,000 Btu/hGREENLAND-M18K/ONon-ducted, up to 1.5 tons |