DUCTLESSAIRE vs TURBRO heat pumps

Measured against models of the same size and duct type, DUCTLESSAIRE and TURBRO split the 6 ratings 2 to 2. DUCTLESSAIRE has 16 outdoor models, TURBRO has 24 outdoor models. DUCTLESSAIRE and TURBRO have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
DUCTLESSAIRE and TURBRO on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, DUCTLESSAIRE and TURBRO split the 6 ratings 2 to 2.
  • DUCTLESSAIRE
  • TURBRO
  • Other ranked manufacturers
DUCTLESS…TURBRO

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDUCTLESSAIRETURBRO
Efficiency index56%median —57%median —
COP at 5°F64%median 2.1064%median 2.08
Capacity retention at 5°F39%median 71%44%median 72%
HSPF258% (higher)median 9.554% (higher)median 10.0
SEER264%median 21.264%median 23.0
EER252% (higher)median 12.050% (higher)median 12.0
Heating capacity at 5°F46%median 12,950 Btu/h47%median 13,600 Btu/h
Outdoor models1624
AHRI certifications2434

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDUCTLESSAIRETURBRO
CEE 2025 Tier 1 (Split ASHP)81.3%13 models79.2%19 models
CEE 2026 Tier 1 (Split ASHP)81.3%13 models79.2%19 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)75%12 models83.3%20 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate62.5%10 models58.3%14 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • DUCTLESSAIRE
  • TURBRO
  • All models of the group
Ducted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDUCTLESSAIRETURBRO
Ducted, 2 tons2 · index 65%None
Ducted, 2.5 to 3 tons1 · index 70%None
Ducted, 3.5 to 4.5 tons1 · index 85%None
Non-ducted, up to 1.5 tons9 · index 54%17 · index 58%
Non-ducted, 2 tons5 · index 48%4 · index 54%
Non-ducted, 2.5 to 3 tons1 · index 59%2 · index 59%
Non-ducted, 3.5 to 4.5 tons1 · index 51%1 · index 42%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDUCTLESSAIRECold-climate score, best modelTURBROCold-climate score, best model
Ducted, 2 tons48.1(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O2 of 2 models qualify · AHRI 217232132No models in this size class
Ducted, 2.5 to 3 tons60.4(50 is the typical model of its size class)454-36-5Z-O1 of 1 models qualify · AHRI 217232141No models in this size class
Ducted, 3.5 to 4.5 tons78.1(50 is the typical model of its size class)454-48-6Z-O1 of 1 models qualify · AHRI 217232138No models in this size class
Non-ducted, up to 1.5 tons85.7(50 is the typical model of its size class) (higher)454-9-O-DAwith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA6 of 9 models qualify · AHRI 21723212780.7(50 is the typical model of its size class)LAPLAND-18K-Owith ductless indoor unit LAPLAND-18K-IAlso listed as LL-18K-O14 of 17 models qualify · AHRI 218004383
Non-ducted, 2 tons54.7(50 is the typical model of its size class)454-24-O-DAwith ductless indoor unit 454-24-I-DA4 of 5 models qualify · AHRI 21723213078.6(50 is the typical model of its size class) (higher)LAPLAND-24K-Owith ductless indoor unit LAPLAND-24K-IAlso listed as LL-24K-O3 of 4 models qualify · AHRI 218004384
Non-ducted, 2.5 to 3 tons48.2(50 is the typical model of its size class)454-36-5Z-O1 of 1 models qualify · AHRI 21723214058.2(50 is the typical model of its size class) (higher)GREENLAND-M27K/O2 of 2 models qualify · AHRI 217222921
Non-ducted, 3.5 to 4.5 tons60.8(50 is the typical model of its size class) (higher)454-48-6Z-O1 of 1 models qualify · AHRI 21723213931.5(50 is the typical model of its size class)GREENLAND-M42K/O1 of 1 models qualify · AHRI 217222923

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDUCTLESSAIREAll-around score, best modelTURBROAll-around score, best model
Ducted, 2 tons64.6(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O2 of 2 models have all five ratings · AHRI 217232132No models in this size class
Ducted, 2.5 to 3 tons70.0(50 is the typical model of its size class)454-36-5Z-O1 of 1 models have all five ratings · AHRI 217232141No models in this size class
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)454-48-6Z-O1 of 1 models have all five ratings · AHRI 217232138No models in this size class
Non-ducted, up to 1.5 tons86.7(50 is the typical model of its size class) (higher)454-9-O-DAwith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA9 of 9 models have all five ratings · AHRI 21723212784.3(50 is the typical model of its size class)LAPLAND-18K-Owith ductless indoor unit LAPLAND-18K-IAlso listed as LL-18K-O15 of 17 models have all five ratings · AHRI 218004383
Non-ducted, 2 tons59.0(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O5 of 5 models have all five ratings · AHRI 21723213170.2(50 is the typical model of its size class) (higher)LAPLAND-24K-Owith ductless indoor unit LAPLAND-24K-IAlso listed as LL-24K-O4 of 4 models have all five ratings · AHRI 218004384
Non-ducted, 2.5 to 3 tons59.3(50 is the typical model of its size class)454-36-5Z-O1 of 1 models have all five ratings · AHRI 21723214065.9(50 is the typical model of its size class) (higher)GREENLAND-M27K/O2 of 2 models have all five ratings · AHRI 217222921
Non-ducted, 3.5 to 4.5 tons53.1(50 is the typical model of its size class) (higher)454-48-6Z-O1 of 1 models have all five ratings · AHRI 21723213942.3(50 is the typical model of its size class)GREENLAND-M42K/O1 of 1 models have all five ratings · AHRI 217222923

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDUCTLESSAIRETURBRO
COP at 5°Fbeats 96% · 2.39454-18-O-DANon-ducted, up to 1.5 tonsbeats 90% · 2.25LAPLAND-18K-OAlso listed as LL-18K-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 67% · 81%454-9-O-DAAlso listed as 454-09-O-DANon-ducted, up to 1.5 tonsbeats 77% · 87%LAPLAND-24K-OAlso listed as LL-24K-ONon-ducted, 2 tons
HSPF2beats 96% · 13.0454-9-O-DAAlso listed as 454-09-O-DANon-ducted, up to 1.5 tonsbeats 81% · 10.5GREENLAND-M18K/ONon-ducted, up to 1.5 tons
SEER2beats 96% · 20.4454-48-6Z-ODucted, 3.5 to 4.5 tonsbeats 90% · 24.0GREENLAND-M27K/ONon-ducted, 2.5 to 3 tons
EER2beats 88% · 14.4454-9-O-DAAlso listed as 454-09-O-DANon-ducted, up to 1.5 tonsbeats 85% · 14.0LAPLAND-18K-OAlso listed as LL-18K-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 77% · 13,400 Btu/h454-18-O-DANon-ducted, up to 1.5 tonsbeats 89% · 16,000 Btu/hGREENLAND-M18K/ONon-ducted, up to 1.5 tons