Skip to content

DUCTLESSAIRE heat pump efficiency: 16 outdoor models compared

DUCTLESSAIRE has 16 heat pump outdoor models certified with this refrigerant group, in 24 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DUCTLESSAIRE makes. DUCTLESSAIRE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
16
AHRI certifications
24
Efficiency index
54%
Typical model vs same-size, same-type peers (20 models)
Meet CEE 2025
81.3%
13 models

How DUCTLESSAIRE compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
DUCTLESSAIRE against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of DUCTLESSAIRE’s own modelsDUCTLESSAIRE is strongest on COP at 5°F (its typical model beats 64% of comparable models) and weakest on capacity retention at 5°F (37%).
  • DUCTLESSAIRE
  • Middle half of its models
  • Other ranked manufacturers
DUCTLESS…

Source: AHRI Directory, NEEP · as of

Average peer percentile of DUCTLESSAIRE’s models
RatingBeats comparable modelsRankRaw median
Efficiency index20 models scored54%Not ranked—
COP at 5°F20 models scored64%Not ranked2.10
Capacity retention at 5°F20 models scored37%Not ranked71%
HSPF220 models scored57%Not ranked9.5
SEER220 models scored62%Not ranked21.2
EER220 models scored50%Not ranked12.0
Heating capacity at 5°F20 models scored45%Not ranked12,950 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
DUCTLESSAIRE’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • DUCTLESSAIRE (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, 2 tons265%51%58%95%
Ducted, 2.5–3 tons170%56%74%95%
Ducted, 3.5–4.5 tons185%69%93%96%
Non-ducted, up to 1.5 tons952%67%63%50%
Non-ducted, 2 tons545%63%38%53%
Non-ducted, 2.5–3 tons158%53%59%84%
Non-ducted, 3.5–4.5 tons151%82%40%63%

Every DUCTLESSAIRE model in the market

DUCTLESSAIRE’s 20 models with a known size and duct type, over the shape of the whole catalog.
DUCTLESSAIRE models by size and ratingColoured: DUCTLESSAIRE · grey shapes: all 14,508 models · lines: catalog medians by size
  • DUCTLESSAIRE models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 20 ductlessaire models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8651.701.802.002.102.46
Ducted, 4 tons7261.801.862.002.122.41
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top DUCTLESSAIRE models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 DUCTLESSAIRE cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1454-9-O-DADUCTLESSAIRE · 454 Serieswith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA1 ton9,000 Btu/h · Non-ducted81%2.2613.08,10024.6CEE 25CEE 26XcelES CC1217232127Non-ducted, up to 1.5 tons84.7
2454-18-O-DADUCTLESSAIRE · 454 Serieswith ductless indoor unit 454-18-I-DA1.5 tons18,000 Btu/h · Non-ducted74%2.3911.913,40023.7CEE 25CEE 26XcelES CC1217232129Non-ducted, up to 1.5 tons78.1
3454-48-6Z-ODUCTLESSAIRE · 454 Series4 tons45,000 Btu/h · Ducted81%2.1010.638,00020.4CEE 25CEE 26XcelES CC3217232138Ducted, 3.5–4.5 tons77.9
4454-12-O-DADUCTLESSAIRE · 454 Serieswith ductless indoor unit 454-12-I-DA1 ton12,000 Btu/h · Non-ducted70%2.2010.28,40023.1CEE 25CEE 26XcelES CC1217232128Non-ducted, up to 1.5 tons61.3
5454-36-5Z-ODUCTLESSAIRE · 454 Series3 tons35,000 Btu/h · Ducted70%2.009.226,00020.0CEE 25CEE 26XcelES CC3217232141Ducted, 2.5–3 tons60.6

All-around best

Top 5 DUCTLESSAIRE models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1454-9-O-DADUCTLESSAIRE · 454 Serieswith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA1 ton9,000 Btu/h · Non-ducted81%2.2613.024.614.4CEE 25CEE 26XcelES CC1217232127Non-ducted, up to 1.5 tons85.684.786.584.7
2454-48-6Z-ODUCTLESSAIRE · 454 Series4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26XcelES CC3217232138Ducted, 3.5–4.5 tons85.177.992.277.9
3454-18-O-DADUCTLESSAIRE · 454 Serieswith ductless indoor unit 454-18-I-DA1.5 tons18,000 Btu/h · Non-ducted74%2.3911.923.713.5CEE 25CEE 26XcelES CC1217232129Non-ducted, up to 1.5 tons78.478.178.678.1
4454-36-5Z-ODUCTLESSAIRE · 454 Series3 tons35,000 Btu/h · Ducted70%2.009.220.011.7CEE 25CEE 26XcelES CC3217232141Ducted, 2.5–3 tons69.560.678.560.6
5454-28-4Z-ODUCTLESSAIRE · 454 SeriesAlso listed as DA27-4Z-O2 tons26,600 Btu/h · Ducted71%2.009.021.012.0CEE 25CEE 26XcelES CC3217232132Ducted, 2 tons64.548.680.548.6

Best model on each rating

DUCTLESSAIRE’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°F454-18-O-DA2.39Non-ducted, up to 1.5 tons96%217232129
Capacity retention at 5°F454-48-6Z-O81%Ducted, 3.5–4.5 tons66%217232138
HSPF2454-9-O-DAAlso listed as 454-09-O-DA13.0Non-ducted, up to 1.5 tons96%217232127
SEER2454-48-6Z-O20.4Ducted, 3.5–4.5 tons96%217232138
EER2454-9-O-DAAlso listed as 454-09-O-DA14.4Non-ducted, up to 1.5 tons87%217232127
Heating capacity at 5°F454-18-O-DA13,400 Btu/hNon-ducted, up to 1.5 tons76%217232129

All 16 DUCTLESSAIRE models in Explore

DUCTLESSAIRE size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
DUCTLESSAIRE: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, 2 tons48.6(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O2 of 2 models qualify · AHRI 21723213264.5(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O2 of 2 models have all five ratings · AHRI 217232132
Ducted, 2.5–3 tons60.6(50 is the typical model of its size class)454-36-5Z-O1 of 1 models qualify · AHRI 21723214169.5(50 is the typical model of its size class)454-36-5Z-O1 of 1 models have all five ratings · AHRI 217232141
Ducted, 3.5–4.5 tons77.9(50 is the typical model of its size class)454-48-6Z-O1 of 1 models qualify · AHRI 21723213885.1(50 is the typical model of its size class)454-48-6Z-O1 of 1 models have all five ratings · AHRI 217232138
Non-ducted, up to 1.5 tons84.7(50 is the typical model of its size class)454-9-O-DAwith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA6 of 9 models qualify · AHRI 21723212785.6(50 is the typical model of its size class)454-9-O-DAwith ductless indoor unit 454-9-I-DAAlso listed as 454-09-O-DA9 of 9 models have all five ratings · AHRI 217232127
Non-ducted, 2 tons52.6(50 is the typical model of its size class)454-24-O-DAwith ductless indoor unit 454-24-I-DA4 of 5 models qualify · AHRI 21723213056.7(50 is the typical model of its size class)454-28-4Z-OAlso listed as DA27-4Z-O5 of 5 models have all five ratings · AHRI 217232131
Non-ducted, 2.5–3 tons47.2(50 is the typical model of its size class)454-36-5Z-O1 of 1 models qualify · AHRI 21723214058.3(50 is the typical model of its size class)454-36-5Z-O1 of 1 models have all five ratings · AHRI 217232140
Non-ducted, 3.5–4.5 tons60.1(50 is the typical model of its size class)454-48-6Z-O1 of 1 models qualify · AHRI 21723213952.8(50 is the typical model of its size class)454-48-6Z-O1 of 1 models have all five ratings · AHRI 217232139

All-around board, every manufacturer

Newest DUCTLESSAIRE certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified DUCTLESSAIRE outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
454-09-O-DADUCTLESSAIRE · 454 Serieswith ductless indoor unit 454-09-I-DA1 ton9,000 Btu/h · Non-ducted2.2681%13.024.6CEE 25CEE 26XcelES CC1217969270
454-24-O-KADuctlessAirewith ductless indoor unit 454-24-I-KA2 tons24,000 Btu/h · Non-ducted2.1068%9.521.0CEE 25CEE 261217559882
454-18-O-KADuctlessAirewith ductless indoor unit 454-18-I-KA1.5 tons18,000 Btu/h · Non-ducted1.8069%9.521.0CEE 25CEE 261217559881
454-12-O-KADuctlessAirewith ductless indoor unit 454-12-I-KA1 ton12,000 Btu/h · Non-ducted1.8076%9.520.0CEE 25CEE 26Xcel1217559880
454-09-O-KADuctlessAirewith ductless indoor unit 454-09-I-KA1 ton9,000 Btu/h · Non-ducted1.8974%10.020.0CEE 25CEE 26Xcel1217559879

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare DUCTLESSAIRE

Manufacturers of a similar size, side by side.

DUCTLESSAIRE includes these brand names as listed in AHRI: DUCTLESSAIRE. Standards are checked against published thresholds; program rules beyond ratings are not checked.