Maestrale vs VillaTherm heat pumps

Measured against models of the same size and duct type, Maestrale and VillaTherm split the 6 ratings 3–3. Maestrale has 24 outdoor models, VillaTherm has 24 outdoor models. Maestrale and VillaTherm have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Maestrale and VillaTherm on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Maestrale and VillaTherm split the 6 ratings 3–3.
  • Maestrale
  • VillaTherm
  • Other ranked manufacturers
MaestraleVillaThe…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMaestraleVillaTherm
Efficiency index64%median —66%median —
COP at 5°F29%median 1.8080%median 2.20
Capacity retention at 5°F72% (higher)median 96%63% (higher)median 74%
HSPF271%median 10.376%median 9.5
SEER279% (higher)median 23.871% (higher)median 18.0
EER261% (higher)median 12.545% (higher)median 11.0
Heating capacity at 5°F62%median 17,800 Btu/h63%median 30,500 Btu/h
Outdoor models2424
AHRI certifications2440

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMaestraleVillaTherm
CEE 2025 Tier 1 (Split ASHP)100%24 models91.7%22 models
CEE 2026 Tier 1 (Split ASHP)100%24 models91.7%22 models
CEE Advanced Tier (Split ASHP)0%0 models16.7%4 models
Xcel Energy Colorado cold-climate ASHP (2025)100%24 models91.7%22 models
DOE Cold Climate Heat Pump Challenge0%0 models16.7%4 models
ENERGY STAR Cold Climate33.3%8 models83.3%20 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 0 groups where both have models
  • Maestrale
  • VillaTherm
  • All models of the group
Ducted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMaestraleVillaTherm
Ducted, 2 tonsNone6 · index 77%
Ducted, 2.5–3 tonsNone6 · index 63%
Ducted, 3.5–4.5 tonsNone12 · index 61%
Non-ducted, up to 1.5 tons14 · index 71%None
Non-ducted, 2 tons4 · index 56%None
Non-ducted, 2.5–3 tons4 · index 58%None
Non-ducted, 3.5–4.5 tons2 · index 42%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMaestraleCold-climate score, best modelVillaThermCold-climate score, best model
Ducted, 2 tonsNo models in this size class89.5(50 is the typical model of its size class)VHP-UCHA-24HDCT-Awith ducted air handler VAH-UCHA-24SHDCALN26 of 6 models qualify · AHRI 218696917
Ducted, 2.5–3 tonsNo models in this size class78.1(50 is the typical model of its size class)VHP-UCHA-36HDCT-Awith ducted air handler VAH-UCHA-36SHDCALN26 of 6 models qualify · AHRI 218696918
Ducted, 3.5–4.5 tonsNo models in this size class79.5(50 is the typical model of its size class)VHP-UCHA-48HDCT-Awith ducted air handler VAH-UCHA-48SHDCALN212 of 12 models qualify · AHRI 218696920
Non-ducted, up to 1.5 tons68.6(50 is the typical model of its size class)TSB20MBOR2J0X24Also listed as TSB20MBOR2J0X2414 of 14 models qualify · AHRI 218331913No models in this size class
Non-ducted, 2 tons58.0(50 is the typical model of its size class)TSA24MAQU1J0X24-Owith ductless indoor unit TSA24MAQU1J0X24-IAlso listed as TSA24MAQU1JOX24-0, TSA24MAQU1J0X24-0, TSA24MAQU1J0X24-O4 of 4 models qualify · AHRI 218331912No models in this size class
Non-ducted, 2.5–3 tons57.5(50 is the typical model of its size class)TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X244 of 4 models qualify · AHRI 218331928No models in this size class
Non-ducted, 3.5–4.5 tons31.2(50 is the typical model of its size class)TSB45MBOR4J0X24Also listed as TSB45MBOR4J0X242 of 2 models qualify · AHRI 218331914No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMaestraleAll-around score, best modelVillaThermAll-around score, best model
Ducted, 2 tonsNo models in this size class85.0(50 is the typical model of its size class)VHP-UCHA-24HDCT-Awith ducted air handler VAH-UCHA-24SHDCALN26 of 6 models have all five ratings · AHRI 218696917
Ducted, 2.5–3 tonsNo models in this size class65.1(50 is the typical model of its size class)VHP-UCHA-36HDCTwith ducted air handler VAH-UCHA-36HDCAlso listed as VHP-UCA-36HDC-A, VHP-UCHA-36HDCT-A6 of 6 models have all five ratings · AHRI 217155422
Ducted, 3.5–4.5 tonsNo models in this size class68.3(50 is the typical model of its size class)VHP-UCHA-48HDCTwith ducted air handler VAH-UCHA-48HDCAlso listed as VHP-UCA-48HDC-A, VHP-UCHA-48HDCT-A12 of 12 models have all five ratings · AHRI 217155425
Non-ducted, up to 1.5 tons76.2(50 is the typical model of its size class)TSA09MAQU1J0X24-Owith ductless indoor unit TSA09MAQU1J0X24-IAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-O14 of 14 models have all five ratings · AHRI 218331911No models in this size class
Non-ducted, 2 tons56.1(50 is the typical model of its size class)TSA24MAQU1J0X24-Owith ductless indoor unit TSA24MAQU1J0X24-IAlso listed as TSA24MAQU1JOX24-0, TSA24MAQU1J0X24-0, TSA24MAQU1J0X24-O4 of 4 models have all five ratings · AHRI 218331912No models in this size class
Non-ducted, 2.5–3 tons65.1(50 is the typical model of its size class)TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X244 of 4 models have all five ratings · AHRI 218331928No models in this size class
Non-ducted, 3.5–4.5 tons42.4(50 is the typical model of its size class)TSB45MBOR4J0X24Also listed as TSB45MBOR4J0X242 of 2 models have all five ratings · AHRI 218331914No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMaestraleVillaTherm
COP at 5°Fbeats 63% · 2.00TSB20MBOR2J0X24Also listed as TSB20MBOR2J0X24Non-ducted, up to 1.5 tonsbeats 89% · 2.30VHP-UCHA-36HDCT-ADucted, 2.5–3 tons
Capacity retention at 5°Fbeats 92% · 106%TSA09MAQU1J0X24-OAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-ONon-ducted, up to 1.5 tonsbeats 92% · 100%VHP-UCHA-24HDCSN4Also listed as VHPSD-UCHA-24HDCSN4, VHPSD-UCHA-24HDCSNDucted, 2 tons
HSPF2beats 80% · 10.5TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X24Non-ducted, 2.5–3 tonsbeats 90% · 10.5VHP-UCHA-48HDCT-ADucted, 3.5–4.5 tons
SEER2beats 91% · 24.0TSB24MBOR3J0X24*Also listed as TSB24MBOR3J0X24Non-ducted, 2.5–3 tonsbeats 87% · 20.0VHP-UCHA-24HDCTAlso listed as VHP-UCA-24HDC-A, VHP-UCHA-24HDCT-ADucted, 2 tons
EER2beats 87% · 14.5TSA09MAQU1J0X24-OAlso listed as TSA09MAQU1JOX24-O, TSA09MAQU1J0X24-ONon-ducted, up to 1.5 tonsbeats 98% · 14.0VHP-UCHA-24HDCTAlso listed as VHP-UCA-24HDC-A, VHP-UCHA-24HDCT-ADucted, 2 tons
Heating capacity at 5°Fbeats 90% · 17,800 Btu/hTSA18MAQU1J0X24-O*Also listed as TSA18MAQU1JOX24-0, TSA18MAQU1J0X24-0, TSA18MAQU1J0X24-ONon-ducted, up to 1.5 tonsbeats 89% · 24,000 Btu/hVHP-UCHA-24HDCSN4Also listed as VHPSD-UCHA-24HDCSN4, VHPSD-UCHA-24HDCSNDucted, 2 tons

More comparisons