- Insights
- Manufacturers
- PREMIUM LEVELLA
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
PREMIUM LEVELLA heat pump efficiency: 17 outdoor models compared
PREMIUM LEVELLA has 17 heat pump outdoor models certified with this refrigerant group, in 17 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes PREMIUM LEVELLA makes. PREMIUM LEVELLA has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 17
- AHRI certifications
- 17
- Efficiency index
- 47%
- Typical model vs same-size, same-type peers (16 models)
- Meet CEE 2025
- 70.6%
- 12 models
How PREMIUM LEVELLA compares with comparable models
- PREMIUM LEVELLA
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index16 models scored | 47% | Not ranked | — |
| COP at 5°F17 models scored | 55% | Not ranked | 2.00 |
| Capacity retention at 5°F16 models scored | 35% | Not ranked | 70% |
| HSPF217 models scored | 47% | Not ranked | 10.0 |
| SEER217 models scored | 48% | Not ranked | 21.0 |
| EER217 models scored | 42% | Not ranked | 12.0 |
| Heating capacity at 5°F17 models scored | 38% | Not ranked | 11,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 70.6% | 12 |
| CEE 2026 Tier 1 (Split ASHP) | 70.6% | 12 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 47.1% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 41.2% | 7 |
Sizes and duct types offered
- PREMIUM LEVELLA (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 10 | 41% | 58% | 43% | 43% |
| Non-ducted, 2 tons | 3 | 44% | 39% | 61% | 45% |
| Non-ducted, 2.5–3 tons | 3 | 65% | 68% | 40% | 52% |
| Non-ducted, 3.5–4.5 tons | 1 | 72% | 37% | 67% | 97% |
Every PREMIUM LEVELLA model in the market
- PREMIUM LEVELLA models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top PREMIUM LEVELLA models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PIAW1825080ABPREMIUM LEVELLA · M serieswith ductless indoor unit PIAW1825079AA | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 15,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 216775680 | Non-ducted, up to 1.5 tons | 79.2 |
| 2PIAWMZ2482380ABPREMIUM LEVELLA · Multi-spilt series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 21,600 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217014451 | Non-ducted, 2 tons | 67.5 |
| 3PIAWMZ1882280ABPREMIUM LEVELLA · Multi-spilt series | 1.5 tons17,700 Btu/h · Non-ducted | 81% | 2.00 | 10.0 | 14,500 | 22.0 | CEE 25CEE 26XcelES CC | 1 | 217014450 | Non-ducted, up to 1.5 tons | 64.5 |
| 4PIAW1225080ABPREMIUM LEVELLA · M serieswith ductless indoor unit PIAW1225079AA | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 8,900 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 216775679 | Non-ducted, up to 1.5 tons | 59.9 |
| 5PIAWMZ3082380ABPREMIUM LEVELLA · Multi-spilt series | 2.5 tons30,000 Btu/h · Non-ducted | 82% | 2.00 | 10.0 | 24,600 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 217014452 | Non-ducted, 2.5–3 tons | 57.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1PIAW1825080ABPREMIUM LEVELLA · M serieswith ductless indoor unit PIAW1825079AA | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 216775680 | Non-ducted, up to 1.5 tons | 82.9 | 79.2 | 86.7 | 79.2 |
| 2PIAWMZ4282480ABPREMIUM LEVELLA · Multi-spilt series | 3.5 tons42,000 Btu/h · Non-ducted | 81% | 2.00 | 10.5 | 24.0 | 12.5 | CEE 25CEE 26XcelES CC | 1 | 217014454 | Non-ducted, 3.5–4.5 tons | 72.1 | 50.3 | 93.8 | 50.3 |
| 3PIAWMZ2482380ABPREMIUM LEVELLA · Multi-spilt series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26XcelES CC | 1 | 217014451 | Non-ducted, 2 tons | 71.8 | 67.5 | 76.1 | 67.5 |
| 4PIAWMZ3082380ABPREMIUM LEVELLA · Multi-spilt series | 2.5 tons30,000 Btu/h · Non-ducted | 82% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26XcelES CC | 1 | 217014452 | Non-ducted, 2.5–3 tons | 66.6 | 57.4 | 75.8 | 57.4 |
| 5PIAWMZ3682380ABPREMIUM LEVELLA · Multi-spilt series | 3 tons36,000 Btu/h · Non-ducted | 71% | 2.00 | 10.0 | 23.0 | 12.3 | CEE 25CEE 26XcelES CC | 1 | 217014453 | Non-ducted, 2.5–3 tons | 62.6 | 51.2 | 73.9 | 51.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | PIAW3417080AB | 2.21 | Non-ducted, 2.5–3 tons | 96% | 216775678 |
| Capacity retention at 5°F | PIAWMZ2482380AB | 90% | Non-ducted, 2 tons | 79% | 217014451 |
| HSPF2 | PIAW1825080AB | 10.5 | Non-ducted, up to 1.5 tons | 79% | 216775680 |
| SEER2 | PIAWMZ4282480AB | 24.0 | Non-ducted, 3.5–4.5 tons | 94% | 217014454 |
| EER2 | PIAWMZ4282480AB | 12.5 | Non-ducted, 3.5–4.5 tons | 87% | 217014454 |
| Heating capacity at 5°F | PIAW1825080AB | 15,000 Btu/h | Non-ducted, up to 1.5 tons | 86% | 216775680 |
PREMIUM LEVELLA size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 79.2(50 is the typical model of its size class)PIAW1825080ABwith ductless indoor unit PIAW1825079AA4 of 10 models qualify · AHRI 216775680 | 82.9(50 is the typical model of its size class)PIAW1825080ABwith ductless indoor unit PIAW1825079AA10 of 10 models have all five ratings · AHRI 216775680 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class)PIAWMZ2482380AB1 of 3 models qualify · AHRI 217014451 | 71.8(50 is the typical model of its size class)PIAWMZ2482380AB3 of 3 models have all five ratings · AHRI 217014451 |
| Non-ducted, 2.5–3 tons | 57.4(50 is the typical model of its size class)PIAWMZ3082380AB2 of 3 models qualify · AHRI 217014452 | 66.6(50 is the typical model of its size class)PIAWMZ3082380AB2 of 3 models have all five ratings · AHRI 217014452 |
| Non-ducted, 3.5–4.5 tons | 50.3(50 is the typical model of its size class)PIAWMZ4282480AB1 of 1 models qualify · AHRI 217014454 | 72.1(50 is the typical model of its size class)PIAWMZ4282480AB1 of 1 models have all five ratings · AHRI 217014454 |
Newest PREMIUM LEVELLA certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| PIAW2411780TBPREMIUM LEVELLAwith ductless indoor unit PIAW2411779TA | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 54% | 9.5 | 17.0 | None | 1 | 218728717 |
| PIAW1811780TBPREMIUM LEVELLAwith ductless indoor unit PIAW1811779TA | 1.5 tons17,000 Btu/h · Non-ducted | 1.80 | 58% | 8.5 | 17.0 | None | 1 | 218728716 |
| PIAW1211780TBPREMIUM LEVELLAwith ductless indoor unit PIAW1211779TA | 1 ton11,500 Btu/h · Non-ducted | 1.75 | 61% | 8.5 | 17.0 | None | 1 | 218728715 |
| PIAW1211770TBPREMIUM LEVELLAwith ductless indoor unit PIAW1211769TA | 1 ton11,500 Btu/h · Non-ducted | 1.90 | 70% | 9.5 | 17.0 | None | 1 | 218728714 |
| PIAWMZ4282480ABPREMIUM LEVELLA · Multi-spilt series | 3.5 tons42,000 Btu/h · Non-ducted | 2.00 | 81% | 10.5 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 217014454 |
Compare PREMIUM LEVELLA