AXTELL vs REVOLV heat pumps
Measured against models of the same size and duct type, AXTELL and REVOLV split the 6 ratings 3 to 3. AXTELL has 3 outdoor models, REVOLV has 11 outdoor models. AXTELL and REVOLV have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AXTELL
- REVOLV
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AXTELL | REVOLV |
|---|---|---|
| Efficiency index | 22% (higher)median — | 17% (higher)median — |
| COP at 5°F | 62% (higher)median 2.22 | 7% (higher)median 1.50 |
| Capacity retention at 5°F | 3%median 53% | 12%median 49% |
| HSPF2 | 4%median 8.2 | 16%median 6.7 |
| SEER2 | 15% (higher)median 18.1 | 13% (higher)median 13.4 |
| EER2 | 25%median 11.3 | 33%median 10.6 |
| Heating capacity at 5°F | 22% (higher)median 9,500 Btu/h | 13% (higher)median 16,000 Btu/h |
| Outdoor models | 3 | 11 |
| AHRI certifications | 3 | 24 |
Share of models meeting each standard
| Standard | AXTELL | REVOLV |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.7%2 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 66.7%2 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AXTELL
- REVOLV
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AXTELL | REVOLV |
|---|---|---|
| Ducted, 2 tons | None | 2 · index 13% |
| Ducted, 2.5 to 3 tons | None | 4 · index 17% |
| Ducted, 3.5 to 4.5 tons | None | 5 · index 20% |
| Non-ducted, up to 1.5 tons | 2 · index 18% | None |
| Non-ducted, 2 tons | 1 · index 28% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AXTELLCold-climate score, best model | REVOLVCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Ducted, 2.5 to 3 tons | No models in this size class | None on this board (0 of 4 models qualify) |
| Ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 5 models qualify) |
| Non-ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | AXTELLAll-around score, best model | REVOLVAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 19.0(50 is the typical model of its size class)HSH4ME5M1SP24Kwith indoor coil C75B(A,H)MX24C*B and furnace MG3P-054U1AAB2 of 2 models have all five ratings · AHRI 217448218 |
| Ducted, 2.5 to 3 tons | No models in this size class | 24.6(50 is the typical model of its size class)HSH4ME5M1SP36Kwith indoor coil C75B(A,H)MX36C*B and furnace MG3P-054U1AAB4 of 4 models have all five ratings · AHRI 217476456 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 28.2(50 is the typical model of its size class)HSH4ME5M1SP42Kwith ducted air handler C85DAMX43U*B5 of 5 models have all five ratings · AHRI 217179931 |
| Non-ducted, up to 1.5 tons | 29.8(50 is the typical model of its size class)AT-INV18HM2A-Owith ductless indoor unit AT-INV18HM2A-I/AT-INV18HM2A-O2 of 2 models have all five ratings · AHRI 218043612 | No models in this size class |
| Non-ducted, 2 tons | 28.1(50 is the typical model of its size class)AT-INV24HM2A-Owith ductless indoor unit AT-INV24HM2A-I/AT-INV24HM2A-O1 of 1 models have all five ratings · AHRI 218043613 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AXTELL | REVOLV |
|---|---|---|
| COP at 5°F | beats 89% · 2.22AT-INV18HM2A-ONon-ducted, up to 1.5 tons | beats 13% · 1.75HSH4ME5M1SP30KDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 4% · 55%AT-INV18HM2A-ONon-ducted, up to 1.5 tons | beats 21% · 52%HSH4ME5M1SP36KDucted, 2.5 to 3 tons |
| HSPF2 | beats 4% · 8.2AT-INV12HM1A-ONon-ducted, up to 1.5 tons | beats 27% · 7.5HSH4ME5M1SP48KDucted, 3.5 to 4.5 tons |
| SEER2 | beats 16% · 18.1AT-INV12HM1A-ONon-ducted, up to 1.5 tons | beats 22% · 14.3HSH4ME5M1SP48KDucted, 3.5 to 4.5 tons |
| EER2 | beats 39% · 11.6AT-INV18HM2A-ONon-ducted, up to 1.5 tons | beats 41% · 11.0HSH4ME5M1SP48KDucted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 54% · 9,500 Btu/hAT-INV18HM2A-ONon-ducted, up to 1.5 tons | beats 22% · 17,800 Btu/hHSH4ME5M1SP36KDucted, 2.5 to 3 tons |