Both views use the same certified data. This device remembers your choice.
CanAir vs ENERGI AIR heat pumps
Measured against models of the same size and duct type, CanAir scores higher on 5 of the 6 ratings. CanAir has 51 outdoor models, ENERGI AIR has 6 outdoor models. CanAir and ENERGI AIR have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CanAir
- ENERGI AIR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CanAir | ENERGI AIR |
|---|---|---|
| Efficiency index | 63% (higher)median — | 58% (higher)median — |
| COP at 5°F | 63% (higher)median 2.00 | 52% (higher)median 2.00 |
| Capacity retention at 5°F | 61% (higher)median 81% | 29% (higher)median 50% |
| HSPF2 | 73% (higher)median 10.0 | 55% (higher)median 8.2 |
| SEER2 | 63% (higher)median 20.5 | 51% (higher)median 15.6 |
| EER2 | 57%median 12.0 | 91%median 12.5 |
| Heating capacity at 5°F | 62% (higher)median 18,000 Btu/h | 32% (higher)median 26,300 Btu/h |
| Outdoor models | 51 | 6 |
| AHRI certifications | 165 | 11 |
Share of models meeting each standard
| Standard | CanAir | ENERGI AIR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 88.2%45 models | 50%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 88.2%45 models | 50%3 models |
| CEE Advanced Tier (Split ASHP) | 2%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 92.2%47 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 2%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 78.4%40 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CanAir
- ENERGI AIR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CanAir | ENERGI AIR |
|---|---|---|
| Ducted, up to 1.5 tons | 9 · index 77% | None |
| Ducted, 2 tons | 4 · index 71% | None |
| Ducted, 2.5 to 3 tons | 9 · index 65% | None |
| Ducted, 3.5 to 4.5 tons | 8 · index 66% | 4 · index 56% |
| Ducted, 5 tons and up | 1 · index 66% | 2 · index 63% |
| Non-ducted, up to 1.5 tons | 25 · index 62% | None |
| Non-ducted, 2 tons | 4 · index 57% | None |
| Non-ducted, 2.5 to 3 tons | 9 · index 56% | None |
| Non-ducted, 3.5 to 4.5 tons | 7 · index 47% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CanAirCold-climate score, best model | ENERGI AIRCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 82.7(50 is the typical model of its size class)4C28SCH18H21with ducted air handler 4C28SEDH18H219 of 9 models qualify · AHRI 217958974 | No models in this size class |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)4C28SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models qualify · AHRI 217958975 | No models in this size class |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)4C28LCH36H21with ducted air handler 4C28LEDH36H216 of 9 models qualify · AHRI 217958976 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)4C28MC648H218 of 8 models qualify · AHRI 215449734 | None on this board (0 of 4 models qualify) |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class)4C28SCH06H21with ductless indoor unit 4C28SEH06H2123 of 25 models qualify · AHRI 215449716 | No models in this size class |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)4C28SCH24H21with ductless indoor unit 4C28SEQ24H214 of 4 models qualify · AHRI 217958956 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)4C28LCH36H21with ductless indoor unit 4C28LEP36H217 of 9 models qualify · AHRI 217958937 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)4C28MC648H216 of 7 models qualify · AHRI 215449735 | No models in this size class |
All-around best
| Size and duct type | CanAirAll-around score, best model | ENERGI AIRAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)4C28SCH09H21with ducted air handler 4C28SEDL09H219 of 9 models have all five ratings · AHRI 217958962 | No models in this size class |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class)4C25SCH24H21with ducted air handler 4C28SEDH24H214 of 4 models have all five ratings · AHRI 217958968 | No models in this size class |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class)4C28MC536H219 of 9 models have all five ratings · AHRI 215449731 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)4C25MC548H218 of 8 models have all five ratings · AHRI 217958993 | 64.0(50 is the typical model of its size class)GLZT7CA4810A*with ducted air handler AMVT60DP1300A4 of 4 models have all five ratings · AHRI 216369299 |
| Ducted, 5 tons and up | 65.9(50 is the typical model of its size class) (higher)4C25LCH60H21with ducted air handler 4C28LEDH60H211 of 1 models have all five ratings · AHRI 217958971 | 63.5(50 is the typical model of its size class)GLZS5BA6010A*with ducted air handler AMST60DU1300A2 of 2 models have all five ratings · AHRI 216369263 |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class)4C28SCH06H21with ductless indoor unit 4C28SEH06H2124 of 25 models have all five ratings · AHRI 215449716 | No models in this size class |
| Non-ducted, 2 tons | 87.8(50 is the typical model of its size class)4C25SCH24H21with ductless indoor unit 4C28SEH24H214 of 4 models have all five ratings · AHRI 215828390 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class)4C28MC536H219 of 9 models have all five ratings · AHRI 215449730 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 75.5(50 is the typical model of its size class)4C28MC648H217 of 7 models have all five ratings · AHRI 215449733 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CanAir | ENERGI AIR |
|---|---|---|
| COP at 5°F | beats 99% · 2.514C25SCH12H21Non-ducted, up to 1.5 tons | beats 54% · 2.00GLZS4BA6010A*Ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 98% · 120%4C28SCH09H21Ducted, up to 1.5 tons | beats 52% · 53%GLZT7CA6010A*Ducted, 5 tons and up |
| HSPF2 | beats 99% · 14.84C28SCH06H21Non-ducted, up to 1.5 tons | beats 66% · 8.2GLZS5BA6010A*Ducted, 5 tons and up |
| SEER2 | beats 99% · 33.34C35SCH09H21Non-ducted, up to 1.5 tons | beats 67% · 17.2GLZT7CA4810A*Ducted, 3.5 to 4.5 tons |
| EER2 | beats 99% · 18.04C28SCH06H21Non-ducted, up to 1.5 tons | beats 94% · 12.5GLZS4BA6010A*Ducted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 99% · 22,600 Btu/h4C35SCH18H21Non-ducted, up to 1.5 tons | beats 55% · 31,000 Btu/hGLZT7CA6010A*Ducted, 5 tons and up |