Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Ecoer vs VENTAGEN heat pumps
Measured against models of the same size and duct type, Ecoer scores higher on 4 of the 6 ratings. Ecoer has 15 outdoor models, VENTAGEN has 15 outdoor models. VENTAGEN has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Ecoer
- VENTAGEN
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Ecoer | VENTAGEN |
|---|---|---|
| Efficiency index | 54%median — · 13th ranked | 58%median — |
| COP at 5°F | 46% (higher)median 1.90 · 23rd ranked | 38% (higher)median 1.90 |
| Capacity retention at 5°F | 65% (higher)median 79% · 3rd ranked | 53% (higher)median 73% |
| HSPF2 | 68% (higher)median 9.0 · 3rd ranked | 60% (higher)median 10.0 |
| SEER2 | 60%median 17.5 · 8th ranked | 74%median 23.0 |
| EER2 | 37%median 11.0 · 27th ranked | 56%median 12.0 |
| Heating capacity at 5°F | 69% (higher)median 33,600 Btu/h · 2nd ranked | 54% (higher)median 16,000 Btu/h |
| Outdoor models | 15 | 15 |
| AHRI certifications | 287 | 15 |
Share of models meeting each standard
| Standard | Ecoer | VENTAGEN |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 93.3%14 models | 100%15 models |
| CEE 2026 Tier 1 (Split ASHP) | 93.3%14 models | 100%15 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 93.3%14 models | 100%15 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 100%15 models | 100%15 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Ecoer
- VENTAGEN
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Ecoer | VENTAGEN |
|---|---|---|
| Ducted, 2 tons | 4 · index 57% | None |
| Ducted, 2.5–3 tons | 4 · index 53% | None |
| Ducted, 3.5–4.5 tons | 7 · index 52% | None |
| Non-ducted, up to 1.5 tons | None | 9 · index 61% |
| Non-ducted, 2 tons | None | 3 · index 53% |
| Non-ducted, 2.5–3 tons | None | 2 · index 58% |
| Non-ducted, 3.5–4.5 tons | None | 1 · index 42% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EcoerCold-climate score, best model | VENTAGENCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | 80.1(50 is the typical model of its size class)EODA19H-2436AB*with indoor coil D(A,C,E)24C3J+TDR and furnace FG7TC-060D-V24B3 of 3 models qualify · AHRI 217627911 | No models in this size class |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class)EODA19H-4860AB*with indoor coil D(A,C,E)36C3J+TDR and furnace FG7TC-060D-V24B6 of 6 models qualify · AHRI 217627934 | No models in this size class |
| Ducted, 3.5–4.5 tons | 68.8(50 is the typical model of its size class)ESCA17H-48ABAwith ducted air handler EAHDEC-48ABA6 of 6 models qualify · AHRI 216706025 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 68.6(50 is the typical model of its size class)TV2H18FM22X4549 of 9 models qualify · AHRI 218327241 |
| Non-ducted, 2 tons | No models in this size class | 58.0(50 is the typical model of its size class)TSVH24HEI2N24O454with ductless indoor unit TSVH24HEI2N24I4543 of 3 models qualify · AHRI 218327252 |
| Non-ducted, 2.5–3 tons | No models in this size class | 57.5(50 is the typical model of its size class)TV3H27FM22X4542 of 2 models qualify · AHRI 218327242 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 31.2(50 is the typical model of its size class)TV5H42FM20X4541 of 1 models qualify · AHRI 218327244 |
All-around best
| Size and duct type | EcoerAll-around score, best model | VENTAGENAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 80.8(50 is the typical model of its size class)EODA19H-2436AB*with ducted air handler EAHDEN-24AB4 of 4 models have all five ratings · AHRI 216445239 | No models in this size class |
| Ducted, 2.5–3 tons | 79.0(50 is the typical model of its size class)EODA19H-4860AB*with ducted air handler EAHDEN-36AB4 of 4 models have all five ratings · AHRI 216620321 | No models in this size class |
| Ducted, 3.5–4.5 tons | 63.7(50 is the typical model of its size class)ERDA19H-60AB*7 of 7 models have all five ratings · AHRI 217463590 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 76.0(50 is the typical model of its size class)TSVH09HEI2N24O454with ductless indoor unit TSVH09HEI2N24I4549 of 9 models have all five ratings · AHRI 218327249 |
| Non-ducted, 2 tons | No models in this size class | 56.1(50 is the typical model of its size class)TSVH24HEI2N24O454with ductless indoor unit TSVH24HEI2N24I4543 of 3 models have all five ratings · AHRI 218327252 |
| Non-ducted, 2.5–3 tons | No models in this size class | 65.1(50 is the typical model of its size class)TV3H27FM22X4542 of 2 models have all five ratings · AHRI 218327242 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 42.4(50 is the typical model of its size class)TV5H42FM20X4541 of 1 models have all five ratings · AHRI 218327244 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Ecoer | VENTAGEN |
|---|---|---|
| COP at 5°F | beats 96% · 2.65EODA19H-4860AB*Ducted, 2.5–3 tons | beats 77% · 2.10TSVH12EI2N24TO454Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 92% · 105%ESCA17H-36ABADucted, 2.5–3 tons | beats 90% · 101%TSVH09HEI2N24O454Non-ducted, up to 1.5 tons |
| HSPF2 | beats 91% · 10.3ESCA17H-36ABADucted, 2.5–3 tons | beats 80% · 10.5TV3H27FM22X454Non-ducted, 2.5–3 tons |
| SEER2 | beats 87% · 20.0EODA19H-2436AB*Ducted, 2 tons | beats 91% · 24.0TV3H27FM22X454Non-ducted, 2.5–3 tons |
| EER2 | beats 90% · 12.5EODA19H-4860AB*Ducted, 2.5–3 tons | beats 87% · 14.5TSVH09HEI2N24O454Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 97% · 39,000 Btu/hESCA17H-36ABADucted, 2.5–3 tons | beats 90% · 17,800 Btu/hTSVH18HEI2N24O454Non-ducted, up to 1.5 tons |