Both views use the same certified data. This device remembers your choice.
Ephoca vs THERMOCORE SYSTEMS heat pumps
Measured against models of the same size and duct type, THERMOCORE SYSTEMS scores higher on 6 of the 6 ratings. Ephoca has 382 outdoor models, THERMOCORE SYSTEMS has 17 outdoor models. Ephoca and THERMOCORE SYSTEMS have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Ephoca
- THERMOCORE SYSTEMS
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Ephoca | THERMOCORE SYSTEMS |
|---|---|---|
| Efficiency index | 32%median — | 62%median — |
| COP at 5°F | 22%median 1.75 | 62%median 2.00 |
| Capacity retention at 5°F | 51%median 73% | 56%median 81% |
| HSPF2 | 41%median 9.2 | 69%median 10.1 |
| SEER2 | 22%median 15.2 | 66%median 21.4 |
| EER2 | 30%median 11.0 | 58%median 12.5 |
| Heating capacity at 5°F | 21%median 6,500 Btu/h | 62%median 19,700 Btu/h |
| Outdoor models | 382 | 17 |
| AHRI certifications | 382 | 35 |
Share of models meeting each standard
| Standard | Ephoca | THERMOCORE SYSTEMS |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 100%17 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 94.1%16 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.4%120 models | 70.6%12 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 48.7%186 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Ephoca
- THERMOCORE SYSTEMS
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Ephoca | THERMOCORE SYSTEMS |
|---|---|---|
| Ducted, up to 1.5 tons | 316 · index 34% | 1 · index 78% |
| Ducted, 2 tons | None | 1 · index 65% |
| Ducted, 2.5 to 3 tons | None | 3 · index 77% |
| Ducted, 3.5 to 4.5 tons | None | 2 · index 70% |
| Ducted, 5 tons and up | None | 1 · index 66% |
| Non-ducted, up to 1.5 tons | 66 · index 23% | 6 · index 65% |
| Non-ducted, 2 tons | None | 2 · index 56% |
| Non-ducted, 2.5 to 3 tons | None | 6 · index 59% |
| Non-ducted, 3.5 to 4.5 tons | None | 3 · index 38% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EphocaCold-climate score, best model | THERMOCORE SYSTEMSCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 61.5(50 is the typical model of its size class)AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 more270 of 316 models qualify · AHRI 217607099 | 71.3(50 is the typical model of its size class) (higher)T7HH25D-H224-C1 of 1 models qualify · AHRI 218003246 |
| Ducted, 2 tons | No models in this size class | 48.1(50 is the typical model of its size class)T725D-H236-C1 of 1 models qualify · AHRI 218003240 |
| Ducted, 2.5 to 3 tons | No models in this size class | 82.7(50 is the typical model of its size class)T7HH25Q-H248-C3 of 3 models qualify · AHRI 218003252 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 81.2(50 is the typical model of its size class)T7HH22X-H272-C2 of 2 models qualify · AHRI 218003255 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 33.6(50 is the typical model of its size class)AWP09R3H1Also listed as AWP09N3H1, AWP09R3H2, AWP09N3H2, AWE09R3H2 and 35 more66 of 66 models qualify · AHRI 217677964 | 75.2(50 is the typical model of its size class) (higher)T7HH21S-H218-Cwith ductless indoor unit T7HH21S-H218-E3 of 6 models qualify · AHRI 218003230 |
| Non-ducted, 2 tons | No models in this size class | 89.6(50 is the typical model of its size class)T7HH21S-H224-Cwith ductless indoor unit T7HH21S-H224-E2 of 2 models qualify · AHRI 218003231 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 78.3(50 is the typical model of its size class)T7HH25Q-H248-C5 of 6 models qualify · AHRI 218003253 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 66.5(50 is the typical model of its size class)T7HH22X-H272-C2 of 3 models qualify · AHRI 218003256 |
All-around best
| Size and duct type | EphocaAll-around score, best model | THERMOCORE SYSTEMSAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.4(50 is the typical model of its size class)AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 more316 of 316 models have all five ratings · AHRI 217650520 | 77.9(50 is the typical model of its size class) (higher)T7HH25D-H224-C1 of 1 models have all five ratings · AHRI 218003246 |
| Ducted, 2 tons | No models in this size class | 64.6(50 is the typical model of its size class)T725D-H236-C1 of 1 models have all five ratings · AHRI 218003240 |
| Ducted, 2.5 to 3 tons | No models in this size class | 83.9(50 is the typical model of its size class)T7HH25Q-H248-C3 of 3 models have all five ratings · AHRI 218003252 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 82.5(50 is the typical model of its size class)T7HH22X-H272-C2 of 2 models have all five ratings · AHRI 218003255 |
| Ducted, 5 tons and up | No models in this size class | 65.9(50 is the typical model of its size class)T7C20S-H260-Cwith ducted air handler T7C20S-H260-EDT1 of 1 models have all five ratings · AHRI 218003237 |
| Non-ducted, up to 1.5 tons | 23.7(50 is the typical model of its size class)APP10*3*1with ductless indoor unit APP10*3*1Also listed as APP10*3*2, APK10*3*2, APP10N4H1, APP10N3H1 and 9 more66 of 66 models have all five ratings · AHRI 213607325 | 83.1(50 is the typical model of its size class) (higher)T7HH25D-H224-C6 of 6 models have all five ratings · AHRI 218003245 |
| Non-ducted, 2 tons | No models in this size class | 78.3(50 is the typical model of its size class)T7HH21S-H224-Cwith ductless indoor unit T7HH21S-H224-E2 of 2 models have all five ratings · AHRI 218003231 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 78.8(50 is the typical model of its size class)T7HH25Q-H248-C6 of 6 models have all five ratings · AHRI 218003251 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 63.6(50 is the typical model of its size class)T7HH22X-H272-C3 of 3 models have all five ratings · AHRI 218003254 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Ephoca | THERMOCORE SYSTEMS |
|---|---|---|
| COP at 5°F | beats 70% · 2.01AVP20R3H1-2Also listed as AVP20R4H1, AVP20N4H1, AVP20R3H1, AVP20N3H1 and 18 moreDucted, up to 1.5 tons | beats 95% · 2.34T7HH21S-H224-CNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 86% · 95%AVK09R3H2Also listed as AVP09R4H1, AVP09N4H1, AVP09R3H1, AVP09N3H1 and 27 moreDucted, up to 1.5 tons | beats 94% · 106%T7HH25Q-H248-CDucted, 2.5 to 3 tons |
| HSPF2 | beats 69% · 9.9AVP10*3*1Also listed as AVP10*3*2, AVE10*3*2, AVK10*3*2, AXP10*3*1 and 35 moreDucted, up to 1.5 tons | beats 98% · 13.5T7HH21S-H224-CNon-ducted, 2 tons |
| SEER2 | beats 45% · 15.4AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 97% · 25.0T725D-H236-CNon-ducted, 2.5 to 3 tons |
| EER2 | beats 55% · 11.7AVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 92% · 15.0T7HH25D-H224-CNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 68% · 12,000 Btu/hAVP19R4H1Also listed as AVP19N4H1, AVP19R3H1, AVP19N3H1, AVP19R4H2 and 21 moreDucted, up to 1.5 tons | beats 97% · 19,000 Btu/hT7HH25D-H224-CNon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Ephoca (median, middle 50%)
- THERMOCORE SYSTEMS (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ephoca, 47°F | 174 | 100% | 100% | 100% | 100% | 100% |
| Ephoca, 17°F | 174 | 60% | 60% | 65% | 69% | 73% |
| Ephoca, 5°F | 174 | 48% | 56% | 57% | 58% | 67% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ephoca, 47°F | 174 | 2.75 | 2.84 | 2.84 | 3.46 | 3.47 |
| Ephoca, 17°F | 174 | 1.91 | 2.02 | 2.02 | 2.32 | 2.33 |
| Ephoca, 5°F | 174 | 1.75 | 1.75 | 1.75 | 1.75 | 1.95 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| THERMOCORE SYSTEMS, 47°F | 17 | 100% | 100% | 100% | 100% | 100% |
| THERMOCORE SYSTEMS, 17°F | 17 | 69% | 73% | 77% | 82% | 85% |
| THERMOCORE SYSTEMS, 5°F | 17 | 61% | 63% | 66% | 79% | 86% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| THERMOCORE SYSTEMS, 47°F | 17 | 2.88 | 3.09 | 3.19 | 3.44 | 3.52 |
| THERMOCORE SYSTEMS, 17°F | 17 | 2 | 2.12 | 2.35 | 2.45 | 2.62 |
| THERMOCORE SYSTEMS, 5°F | 17 | 1.9 | 2 | 2 | 2.15 | 2.24 |
Source: NEEP ccASHP list · as of