Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
GCHV vs ZOKOP heat pumps
Measured against models of the same size and duct type, GCHV scores higher on 4 of the 6 ratings. GCHV has 20 outdoor models, ZOKOP has 37 outdoor models. GCHV and ZOKOP have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- GCHV
- ZOKOP
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | GCHV | ZOKOP |
|---|---|---|
| Efficiency index | 38% (higher)median — | 34% (higher)median — |
| COP at 5°F | 39% (higher)median 1.84 | 34% (higher)median 1.80 |
| Capacity retention at 5°F | 37% (higher)median 70% | 33% (higher)median 72% |
| HSPF2 | 28%median 7.5 | 46%median 9.5 |
| SEER2 | 30%median 14.3 | 36%median 20.0 |
| EER2 | 51% (higher)median 11.7 | 26% (higher)median 10.5 |
| Heating capacity at 5°F | 45% (higher)median 11,100 Btu/h | 40% (higher)median 9,500 Btu/h |
| Outdoor models | 20 | 37 |
| AHRI certifications | 48 | 37 |
Share of models meeting each standard
| Standard | GCHV | ZOKOP |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 20%4 models | 67.6%25 models |
| CEE 2026 Tier 1 (Split ASHP) | 20%4 models | 67.6%25 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 20%4 models | 56.8%21 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 10%2 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- GCHV
- ZOKOP
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | GCHV | ZOKOP |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 14% | None |
| Ducted, 2 tons | 5 · index 57% | None |
| Ducted, 2.5–3 tons | 4 · index — | None |
| Ducted, 3.5–4.5 tons | 5 · index 59% | None |
| Non-ducted, up to 1.5 tons | None | 27 · index 31% |
| Non-ducted, 2 tons | None | 3 · index 35% |
| Non-ducted, 2.5–3 tons | None | 6 · index 52% |
| Non-ducted, 3.5–4.5 tons | None | 1 · index 27% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | GCHVCold-climate score, best model | ZOKOPCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 8.8(50 is the typical model of its size class)CPT-DD09AGR4-VTA1 of 6 models qualify · AHRI 218724431 | No models in this size class |
| Ducted, 2 tons | 67.2(50 is the typical model of its size class)COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0)2 of 5 models qualify · AHRI 215223218 | No models in this size class |
| Ducted, 2.5–3 tons | None on this board (0 of 4 models qualify) | No models in this size class |
| Ducted, 3.5–4.5 tons | 64.7(50 is the typical model of its size class)COT-D60HNR8-GA01(J0)with ducted air handler CAH-D60HNR8-FMD(J0)Also listed as COT-D48HNR8-GA01(J0)2 of 5 models qualify · AHRI 215223221 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 68.6(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O14 of 27 models qualify · AHRI 216020699 |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 3 models qualify) |
| Non-ducted, 2.5–3 tons | No models in this size class | 57.5(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models qualify · AHRI 216020700 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 24.7(50 is the typical model of its size class)ZP42M2/19-O1 of 1 models qualify · AHRI 218035871 |
All-around best
| Size and duct type | GCHVAll-around score, best model | ZOKOPAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 18.3(50 is the typical model of its size class)CPT-DD12AGR4-VTA4 of 6 models have all five ratings · AHRI 217175307 | No models in this size class |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class)COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0)3 of 5 models have all five ratings · AHRI 215223218 | No models in this size class |
| Ducted, 2.5–3 tons | None on this board (0 of 4 models have all five ratings) | No models in this size class |
| Ducted, 3.5–4.5 tons | 64.4(50 is the typical model of its size class)COT-D60HNR8-GA01(J0)with ducted air handler CAH-D48HNR8-FMD(J0)2 of 5 models have all five ratings · AHRI 215223220 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 72.2(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O27 of 27 models have all five ratings · AHRI 216020699 |
| Non-ducted, 2 tons | No models in this size class | 39.1(50 is the typical model of its size class)TSC-24HA2/I2XI18B-Owith ductless indoor unit TSC-24HA2/I2XI18B-IAlso listed as TSC-24HA2/I2XI18B-O3 of 3 models have all five ratings · AHRI 216020695 |
| Non-ducted, 2.5–3 tons | No models in this size class | 65.1(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models have all five ratings · AHRI 216020700 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 27.2(50 is the typical model of its size class)ZP42M2/19-O1 of 1 models have all five ratings · AHRI 218035871 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | GCHV | ZOKOP |
|---|---|---|
| COP at 5°F | beats 69% · 2.10COT-D60HNR8-GA01(J0)Ducted, 3.5–4.5 tons | beats 71% · 2.10TSC-24HA2/I2XI18B-OAlso listed as TSC-24HA2/I2XI18B-ONon-ducted, 2 tons |
| Capacity retention at 5°F | beats 66% · 83%COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0)Ducted, 2 tons | beats 61% · 80%TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 69% · 9.0COT-D60HNR8-GA01(J0)Ducted, 3.5–4.5 tons | beats 80% · 10.5TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-ONon-ducted, 2.5–3 tons |
| SEER2 | beats 87% · 20.0COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0)Ducted, 2 tons | beats 91% · 24.0TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-ONon-ducted, 2.5–3 tons |
| EER2 | beats 93% · 13.3COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0)Ducted, 2 tons | beats 70% · 13.0TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 74% · 42,500 Btu/hCOT-D60HNR8-GA01(J0)Also listed as COT-D48HNR8-GA01(J0)Ducted, 3.5–4.5 tons | beats 88% · 16,000 Btu/hTMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-ONon-ducted, up to 1.5 tons |