Skip to content

LPS Legacy vs PolarWave heat pumps

Measured against models of the same size and duct type, LPS Legacy scores higher on 6 of the 6 ratings. LPS Legacy has 65 outdoor models, PolarWave has 20 outdoor models. LPS Legacy and PolarWave have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
LPS Legacy and PolarWave on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, LPS Legacy scores higher on 6 of the 6 ratings.
  • LPS Legacy
  • PolarWave
  • Other ranked manufacturers
LPS Lega…PolarWave

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingLPS LegacyPolarWave
Efficiency index61% (higher)median —51% (higher)median —
COP at 5°F61% (higher)median 2.0052% (higher)median 2.00
Capacity retention at 5°F59% (higher)median 78%44% (higher)median 71%
HSPF269% (higher)median 9.858% (higher)median 9.5
SEER263% (higher)median 19.557% (higher)median 19.2
EER255% (higher)median 12.042% (higher)median 11.2
Heating capacity at 5°F61% (higher)median 20,000 Btu/h55% (higher)median 21,600 Btu/h
Outdoor models6520
AHRI certifications19326

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardLPS LegacyPolarWave
CEE 2025 Tier 1 (Split ASHP)83.1%54 models75%15 models
CEE 2026 Tier 1 (Split ASHP)80%52 models75%15 models
CEE Advanced Tier (Split ASHP)4.6%3 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)73.8%48 models65%13 models
DOE Cold Climate Heat Pump Challenge4.6%3 models0%0 models
ENERGY STAR Cold Climate73.8%48 models70%14 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 7 groups where both have models
  • LPS Legacy
  • PolarWave
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeLPS LegacyPolarWave
Ducted, up to 1.5 tons11 · index 77%None
Ducted, 2 tons6 · index 73%3 · index 60%
Ducted, 2.5–3 tons13 · index 65%3 · index 60%
Ducted, 3.5–4.5 tons10 · index 66%5 · index 53%
Ducted, 5 tons and up2 · index 65%None
Non-ducted, up to 1.5 tons25 · index 59%6 · index 48%
Non-ducted, 2 tons7 · index 56%3 · index 44%
Non-ducted, 2.5–3 tons12 · index 50%2 · index 32%
Non-ducted, 3.5–4.5 tons8 · index 44%1 · index 53%
Non-ducted, 5 tons and up1 · index 61%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeLPS LegacyCold-climate score, best modelPolarWaveCold-climate score, best model
Ducted, up to 1.5 tons93.5(50 is the typical model of its size class)D5CSHAH06AAKwith ducted air handler D5FSDAH06XAK10 of 11 models qualify · AHRI 215324834No models in this size class
Ducted, 2 tons85.7(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK6 of 6 models qualify · AHRI 21532485766.3(50 is the typical model of its size class)EZ-24-HPBwith ducted air handler EZ-24-AHB3 of 3 models qualify · AHRI 216980861
Ducted, 2.5–3 tons83.2(50 is the typical model of its size class) (higher)D5CMHAH36EAK9 of 13 models qualify · AHRI 21535762373.1(50 is the typical model of its size class)EZ-36-HPBwith ducted air handler EZ-36-AHB3 of 3 models qualify · AHRI 216980862
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class) (higher)D5CMHAH48FAK10 of 10 models qualify · AHRI 21535762670.5(50 is the typical model of its size class)EZ-48Z-M5B5 of 5 models qualify · AHRI 216980937
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tons96.8(50 is the typical model of its size class) (higher)D5CPRAH18AAwith ductless indoor unit D5FPHAH18XAK17 of 25 models qualify · AHRI 21541335473.1(50 is the typical model of its size class)EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MB3 of 6 models qualify · AHRI 216980906
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ductless indoor unit D5FSCAH24XAK7 of 7 models qualify · AHRI 21532485542.8(50 is the typical model of its size class)EZ-27Z-M3B1 of 3 models qualify · AHRI 216980932
Non-ducted, 2.5–3 tons89.4(50 is the typical model of its size class) (higher)D5CLHAH36AAKwith ductless indoor unit D5FCFAH36XAK8 of 12 models qualify · AHRI 21532489041.3(50 is the typical model of its size class)EZ-36Z-M4B1 of 2 models qualify · AHRI 216980933
Non-ducted, 3.5–4.5 tons75.5(50 is the typical model of its size class) (higher)D5CMHAH48FAK7 of 8 models qualify · AHRI 21535762745.0(50 is the typical model of its size class)EZ-48Z-M5B1 of 1 models qualify · AHRI 216980938
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeLPS LegacyAll-around score, best modelPolarWaveAll-around score, best model
Ducted, up to 1.5 tons95.6(50 is the typical model of its size class)D5CSHAH06AAKwith ducted air handler D5FSDAH06XAK11 of 11 models have all five ratings · AHRI 215324834No models in this size class
Ducted, 2 tons80.0(50 is the typical model of its size class) (higher)D5CSHAH24AAKwith ducted air handler D5FSDAH24XHK6 of 6 models have all five ratings · AHRI 21532485768.3(50 is the typical model of its size class)EZ-27Z-M3B3 of 3 models have all five ratings · AHRI 216980931
Ducted, 2.5–3 tons85.5(50 is the typical model of its size class) (higher)D5CMHAH30EAK13 of 13 models have all five ratings · AHRI 21535762067.3(50 is the typical model of its size class)EZ-36-HPBwith ducted air handler EZ-36-AHB3 of 3 models have all five ratings · AHRI 216980862
Ducted, 3.5–4.5 tons85.7(50 is the typical model of its size class) (higher)D5CMRAH48FAK10 of 10 models have all five ratings · AHRI 21535764780.2(50 is the typical model of its size class)EZ-48Z-M5B5 of 5 models have all five ratings · AHRI 216980937
Ducted, 5 tons and up65.9(50 is the typical model of its size class)D5CLRAH58AAKwith ducted air handler D5FLDAH58XHK2 of 2 models have all five ratings · AHRI 215324904No models in this size class
Non-ducted, up to 1.5 tons96.5(50 is the typical model of its size class) (higher)D5CSHAH06AAKwith ductless indoor unit D5FSHAH06XAK25 of 25 models have all five ratings · AHRI 21532483273.3(50 is the typical model of its size class)EZ-18ZPL-HP230Bwith ductless indoor unit EZ-18W-MB6 of 6 models have all five ratings · AHRI 216980906
Non-ducted, 2 tons88.5(50 is the typical model of its size class) (higher)D5CSRAH24AAKwith ductless indoor unit D5FPHAH18XAK7 of 7 models have all five ratings · AHRI 21532487956.2(50 is the typical model of its size class)EZ-24ZPL-HP230Bwith ductless indoor unit EZ-24W-MB3 of 3 models have all five ratings · AHRI 216980907
Non-ducted, 2.5–3 tons85.8(50 is the typical model of its size class) (higher)D5CMHAH30EAK12 of 12 models have all five ratings · AHRI 21535761953.2(50 is the typical model of its size class)EZ-36Z-M4B2 of 2 models have all five ratings · AHRI 216980933
Non-ducted, 3.5–4.5 tons76.7(50 is the typical model of its size class) (higher)D5CMHAH48FAK8 of 8 models have all five ratings · AHRI 21535762552.8(50 is the typical model of its size class)EZ-48Z-M5B1 of 1 models have all five ratings · AHRI 216980936
Non-ducted, 5 tons and up61.3(50 is the typical model of its size class)D5CMRAH55FAK1 of 1 models have all five ratings · AHRI 215357649No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingLPS LegacyPolarWave
COP at 5°Fbeats 99% · 2.51D5CSRAH12AAKNon-ducted, up to 1.5 tonsbeats 98% · 2.44EZ-18ZPL-HP230BNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 150%D5CPRAH06AAKNon-ducted, up to 1.5 tonsbeats 91% · 105%EZ-36-HPBDucted, 2.5–3 tons
HSPF2beats 100% · 15.6D5CPRAH06AAKNon-ducted, up to 1.5 tonsbeats 91% · 10.3EZ-36-HPBDucted, 2.5–3 tons
SEER2beats 99% · 33.1D5CPRAH06AAKNon-ducted, up to 1.5 tonsbeats 91% · 20.0EZ-48Z-M5BDucted, 3.5–4.5 tons
EER2beats 100% · 14.5D5CSHAH06AAKDucted, up to 1.5 tonsbeats 83% · 12.0EZ-48Z-M5BDucted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hD5CPRAH18AANon-ducted, up to 1.5 tonsbeats 97% · 39,000 Btu/hEZ-36-HPBDucted, 2.5–3 tons

More comparisons