Both views use the same certified data. This device remembers your choice.
Rheem vs York heat pumps
Measured against models of the same size and duct type, York scores higher on 5 of the 6 ratings. Rheem has 346 outdoor models, York has 239 outdoor models.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Rheem
- York
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Rheem | York |
|---|---|---|
| Efficiency index | 50%median — · 20th ranked | 54%median — · 12th ranked |
| COP at 5°F | 59%median 2.06 · 11th ranked | 67%median 2.13 · 2nd ranked |
| Capacity retention at 5°F | 49%median 65% · 19th ranked | 53%median 70% · 14th ranked |
| HSPF2 | 44%median 7.5 · 21st ranked | 45%median 8.1 · 20th ranked |
| SEER2 | 42% (higher)median 15.2 · 24th ranked | 40% (higher)median 16.0 · 25th ranked |
| EER2 | 41%median 10.6 · 24th ranked | 58%median 11.7 · 11th ranked |
| Heating capacity at 5°F | 49%median 19,650 Btu/h · 19th ranked | 55%median 20,000 Btu/h · 14th ranked |
| Outdoor models | 346 | 239 |
| AHRI certifications | 26,750 | 109,938 |
Share of models meeting each standard
| Standard | Rheem | York |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 36.4%126 models | 54.4%130 models |
| CEE 2026 Tier 1 (Split ASHP) | 34.7%120 models | 54.4%130 models |
| CEE Advanced Tier (Split ASHP) | 1.7%6 models | 7.5%18 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 34.4%119 models | 41.4%99 models |
| DOE Cold Climate Heat Pump Challenge | 1.7%6 models | 7.5%18 models |
| ENERGY STAR Cold Climate | 33.2%115 models | 38.1%91 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Rheem
- York
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Rheem | York |
|---|---|---|
| Ducted, up to 1.5 tons | 33 · index 56% | 24 · index 56% |
| Ducted, 2 tons | 36 · index 42% | 21 · index 48% |
| Ducted, 2.5 to 3 tons | 91 · index 46% | 58 · index 50% |
| Ducted, 3.5 to 4.5 tons | 122 · index 49% | 70 · index 50% |
| Ducted, 5 tons and up | 32 · index 45% | 13 · index 43% |
| Non-ducted, up to 1.5 tons | 39 · index 60% | 49 · index 61% |
| Non-ducted, 2 tons | 9 · index 55% | 17 · index 63% |
| Non-ducted, 2.5 to 3 tons | 18 · index 55% | 16 · index 52% |
| Non-ducted, 3.5 to 4.5 tons | 12 · index 49% | 6 · index 56% |
| Non-ducted, 5 tons and up | 2 · index 43% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | RheemCold-climate score, best model | YorkCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I20 of 33 models qualify · AHRI 215864373 | 80.8(50 is the typical model of its size class)YPAS18BLFASDQ1with ducted air handler YPPIMB18UFA1DQ11 of 22 models qualify · AHRI 218694255 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)ML24HP230NEXH-Owith ducted air handler ML24HP230HSDUC-I17 of 35 models qualify · AHRI 215864380 | 90.1(50 is the typical model of its size class) (higher)HH824E2S11with ducted air handler D(A,C,E)36A4K+JMC12B2SN1+TDR12 of 23 models qualify · AHRI 218026253 |
| Ducted, 2.5 to 3 tons | 94.3(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ29 of 91 models qualify · AHRI 218029736 | 92.1(50 is the typical model of its size class)HH836E2S11with indoor coil D(A,C,E)36A4K+TDR and furnace Z9ET080C16SMPS122 of 60 models qualify · AHRI 218350129 |
| Ducted, 3.5 to 4.5 tons | 95.2(50 is the typical model of its size class) (higher)RD18AY48AJVCwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZ35 of 123 models qualify · AHRI 218827549 | 90.1(50 is the typical model of its size class)HH860E2S11with ducted air handler DM59A4K+JMC20D2SN1+TDR19 of 68 models qualify · AHRI 218026269 |
| Ducted, 5 tons and up | 78.1(50 is the typical model of its size class) (higher)RP17AY60AJVCwith indoor coil RCFY6024STANM and furnace R801V1255A24UHNAlso sold as SURE SP17AY60AJVC2 of 32 models qualify · AHRI 218160560 | 64.2(50 is the typical model of its size class)PH9E60N00D212 of 13 models qualify · AHRI 218450295 |
| Non-ducted, up to 1.5 tons | 94.9(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ductless indoor unit ML06HP2301WYCAS-I30 of 39 models qualify · AHRI 215864386 | 92.4(50 is the typical model of its size class)YPAS18BLFASDQ1with ductless indoor unit YPCIB18UFA1DQ42 of 49 models qualify · AHRI 218694256 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)ML24HP230NEXH-Owith ductless indoor unit ML24HP230STDCAS-I9 of 9 models qualify · AHRI 215864372 | 97.0(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ14 of 17 models qualify · AHRI 218694257 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)ML36HP230LCMH-Owith ductless indoor unit ML36HP230FLO-I15 of 18 models qualify · AHRI 215864403 | 97.3(50 is the typical model of its size class) (higher)YPAS30BLFASDQ1with ductless indoor unit YPCIB30UFA1DQ12 of 16 models qualify · AHRI 218694248 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class) (higher)ML48HP230MULH-O*Also listed as ML48HP230MULH - O11 of 12 models qualify · AHRI 216623576 | 59.5(50 is the typical model of its size class)YPAS48BUFASDQ1with ductless indoor unit YPPFCB48UFA1DQ4 of 6 models qualify · AHRI 218696687 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | No models in this size class |
All-around best
| Size and duct type | RheemAll-around score, best model | YorkAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 95.1(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I33 of 33 models have all five ratings · AHRI 215864373 | 80.7(50 is the typical model of its size class)YPAS12BLFASDQ1with ducted air handler YPPIMB12UFA1DQ23 of 23 models have all five ratings · AHRI 218694251 |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class) (higher)ML24HP230NEX-Owith ducted air handler ML24HP230HSDUC-I33 of 33 models have all five ratings · AHRI 215864360 | 77.5(50 is the typical model of its size class)HH824E2S11with ducted air handler D(A,C,E)36A4K+JME08B2SN1+TDR25 of 25 models have all five ratings · AHRI 218026254 |
| Ducted, 2.5 to 3 tons | 92.7(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ69 of 92 models have all five ratings · AHRI 218029736 | 91.3(50 is the typical model of its size class)YPAS30BUFASDQ1with ducted air handler YPPIMB30UFA1DQ39 of 55 models have all five ratings · AHRI 218694240 |
| Ducted, 3.5 to 4.5 tons | 86.4(50 is the typical model of its size class) (higher)RD18AY48AJVCwith ducted air handler L(E,G)M60IJ71 of 118 models have all five ratings · AHRI 218029742 | 86.0(50 is the typical model of its size class)HH860E2S11with ducted air handler D(A,C,E)60B3K+JMC20D2SN1+TDR45 of 69 models have all five ratings · AHRI 218014963 |
| Ducted, 5 tons and up | 70.6(50 is the typical model of its size class) (higher)RP17AY60AJVCwith ducted air handler RH2TY6024STANNAlso sold as SURE SP17AY60AJVC24 of 38 models have all five ratings · AHRI 218160613 | 70.5(50 is the typical model of its size class)PH9E60N00D216 of 14 models have all five ratings · AHRI 218450295 |
| Non-ducted, up to 1.5 tons | 94.5(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ductless indoor unit ML06HP230NEX-I38 of 39 models have all five ratings · AHRI 215864338 | 90.1(50 is the typical model of its size class)YRACXJ12WHAAwith ductless indoor unit YRAKXJ12PHAA49 of 49 models have all five ratings · AHRI 218037193 |
| Non-ducted, 2 tons | 78.3(50 is the typical model of its size class)ML24HP230CALH-Owith ductless indoor unit ML24HP230CALH-I8 of 8 models have all five ratings · AHRI 215864348 | 85.7(50 is the typical model of its size class) (higher)YPAS24BLFASDQ1with ductless indoor unit YPCIB24UFA1DQ17 of 17 models have all five ratings · AHRI 218694257 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class)ML36HP230MULH-O*Also listed as ML36HP230MULH - O18 of 19 models have all five ratings · AHRI 216623571 | 85.2(50 is the typical model of its size class) (higher)YPAS30BUFASDQ1with ductless indoor unit YPCIB30UFA1DQ16 of 16 models have all five ratings · AHRI 218694244 |
| Non-ducted, 3.5 to 4.5 tons | 75.4(50 is the typical model of its size class) (higher)ML48HP230MULH-O*Also listed as ML48HP230MULH - O12 of 12 models have all five ratings · AHRI 216623574 | 67.8(50 is the typical model of its size class)YRAMX42N5HBA6 of 6 models have all five ratings · AHRI 218080472 |
| Non-ducted, 5 tons and up | 59.0(50 is the typical model of its size class)ML55HP230MUL-O*2 of 2 models have all five ratings · AHRI 216623550 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Rheem | York |
|---|---|---|
| COP at 5°F | beats 100% · 3.08RP15AY48AJ2NDucted, 3.5 to 4.5 tons | beats 100% · 3.55UPC24CN23STG1Ducted, 2 tons |
| Capacity retention at 5°F | beats 100% · 150%ML06HP230CALH-ONon-ducted, up to 1.5 tons | beats 100% · 147%YRACXJ09WHAANon-ducted, up to 1.5 tons |
| HSPF2 | beats 100% · 15.6ML06HP230CALH-ONon-ducted, up to 1.5 tons | beats 100% · 12.0YPAS30BUFASDQ1Non-ducted, 2.5 to 3 tons |
| SEER2 | beats 100% · 35.0ML06HP230CALH-ONon-ducted, up to 1.5 tons | beats 100% · 22.0YH960E2C11Also sold as Coleman XH960E2C11Ducted, 3.5 to 4.5 tons |
| EER2 | beats 99% · 17.4ML06HP230CALH-ONon-ducted, up to 1.5 tons | beats 99% · 14.4YPAS36BLFASDQ1Non-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 100% · 35,800 Btu/hRP15AY30AJ2NDucted, 2 tons | beats 100% · 23,000 Btu/hYRACXJ18WHAAAlso listed as YRACXJ18WHBANon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Rheem (median, middle 50%)
- York (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 100% | 100% | 100% | 100% | 100% |
| Rheem, 17°F | 118 | 63% | 67% | 73% | 82% | 90% |
| Rheem, 5°F | 118 | 57% | 62% | 70% | 79% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 2.87 | 2.97 | 3.17 | 3.44 | 3.61 |
| Rheem, 17°F | 118 | 2.11 | 2.24 | 2.38 | 2.48 | 2.61 |
| Rheem, 5°F | 118 | 1.9 | 2 | 2 | 2.1 | 2.22 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| York, 47°F | 50 | 100% | 100% | 100% | 100% | 100% |
| York, 17°F | 50 | 66% | 73% | 79% | 88% | 97% |
| York, 5°F | 50 | 58% | 62% | 72% | 80% | 84% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| York, 47°F | 50 | 2.7 | 2.96 | 3.23 | 3.4 | 3.62 |
| York, 17°F | 50 | 2.15 | 2.2 | 2.3 | 2.4 | 2.51 |
| York, 5°F | 50 | 1.8 | 1.88 | 2 | 2.1 | 2.2 |
Source: NEEP ccASHP list · as of