Skip to content

Top cold-climate picks: ducted, 3.5 to 4.5 tons

Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F. COP at 5°F alone is not used: it is measured at whatever heat output the unit delivers at 5°F, so a unit with little output there can still post a high COP; it has its own single-rating board above. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

LeaderboardsData as of updated · sources

Top cold-climate picks: Ducted, 3.5 to 4.5 tons

1,306 of 2,698 models in this size class qualify. 997 keep less than 70% of their heat at 5°F and 390 have no 5°F heat output rating, so they cannot qualify. 623 of the qualifiers are from manufacturers with a QMID on file (the ranked pool).

Ducted, 3.5 to 4.5 tons: qualifiers ranked by cold-climate score (mean of the three peer percentiles); equal scores go to the higher heat output at 5°F. Every number in a row is from the pairing the score is computed on: in each duct type, the model’s best-scoring pairing that keeps at least 70% of its heat.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2EER2MeetsCombosAHRI ref.ScoreBeats on Cap. 5/47Beats on COP@5°FBeats on HSPF2
1RD18AY48AJVCRHEEMwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZRheem3.5 tons39,000 Btu/h · Ducted125%2.8010.050,00017.09.8CEE 25CEE 26CEE AdvXcelDOEES CC1,05221882754995.2100%98%87%
25TWV0X48A1TRANEwith indoor coil D(A,C,E)60B4J+TDR and furnace S9V2D120U5PSC+LRPTrane3.5 tons41,500 Btu/h · Ducted108%2.819.549,50020.211.7CEE 25CEE 26CEE AdvXcelDOEES CC20721679459692.8100%99%80%
3BOVA-60MTB-M19EBOSCHwith ducted air handler AE*L+DM60B4Z+TXV+TDRBosch4 tons49,000 Btu/h · Ducted120%2.479.564,00019.011.7CEE 25CEE 26CEE AdvXcelDOEES CC19321869351890.7100%92%80%
4SL22KLV-060-230A**LENNOXwith indoor coil D(A,C,E)60D3J+TDR and furnace SLP99UH110XV60CLennox4.5 tons52,500 Btu/h · Ducted115%3.099.060,00020.011.2CEE 25CEE 26CEE AdvXcelDOEES CC19921744391890.6100%100%72%
5KUMXA481ALG · KUMXA481ALG4 tons48,000 Btu/h · Ducted100%2.3310.052,50018.512.6CEE 25CEE 26CEE AdvXcelDOEES CC321540863790.495%89%87%
6HH860E2S11COLEMANwith ducted air handler DM59A4K+JMC20D2SN1+TDRYork3.5 tons43,000 Btu/h · Ducted108%2.889.036,60019.011.7CEE 25CEE 26CEE AdvXcelDOEES CC9,47321802626990.1100%99%72%
7H5H0V48*K*AAA*HEILwith indoor coil D(A,C,E)61A3J+TDR and furnace *80CSU0802120ACarrier3.5 tons43,000 Btu/h · Ducted103%2.709.050,00018.09.0CEE 25CEE 26CEE AdvXcelDOEES CC1,25021837271489.5100%97%72%
8KUMXA421ALG · KUMXA421ALG3.5 tons42,000 Btu/h · Ducted100%2.2710.048,00019.013.1CEE 25CEE 26CEE AdvXcelDOEES CC321540234889.395%85%87%
9GUD60W2/NHE-D(U)GREE · E Serieswith ducted air handler HND60A/NHA-OAlso sold as Tosot TUH60-48D32E2O; also listed as FXU60HP230V1R32AO, HW60/NHE-DGree4.5 tons53,000 Btu/h · Ducted100%2.2010.554,00018.011.0CEE 25CEE 26CEE AdvXcelDOEES CC1321804337188.795%80%91%
105TCV0X61A1TRANE · 20 TruComfort Variable Speed Cold Climate Heat Pumpwith ducted air handler 5TEMCD07BV51+TDRAlso sold as American Standard 5A5V0X61A1Trane4 tons48,000 Btu/h · Ducted100%2.2210.055,50018.011.5CEE 25CEE 26CEE AdvXcelDOEES CC2221879228188.395%82%87%

Download CSV of the Ducted, 3.5 to 4.5 tons cold-climate board