Top cold-climate picks: ducted, 5 tons and up

Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F. COP at 5°F alone is not used: it is measured at whatever heat output the unit delivers at 5°F, so a unit with little output there can still post a high COP; it has its own single-rating board above. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

LeaderboardsData as of updated · sources

Top cold-climate picks: Ducted, 5 tons and up

81 of 495 models in this size class qualify. 281 keep less than 70% of their heat at 5°F and 133 have no 5°F heat output rating, so they cannot qualify. 66 of the qualifiers are from manufacturers with a QMID on file (the ranked pool).

Ducted, 5 tons and up: qualifiers ranked by cold-climate score (mean of the three peer percentiles); equal scores go to the higher heat output at 5°F. Every number in a row is from the pairing the score is computed on: in each duct type, the model’s best-scoring pairing that keeps at least 70% of its heat.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2EER2MeetsCombosAHRI ref.ScoreBeats on Cap. 5/47Beats on COP@5°FBeats on HSPF2
1MCY-MUB0608HS2P-ULTOSHIBA CARRIER · MCY-MUB0608HS2P-ULCarrier5 tons60,000 Btu/h · Ducted73%2.2210.147,00018.910.1CEE 25CEE 26Xcel521676324994.891%95%99%
2KUMXB601ALG · KUMXB601ALG5 tons60,000 Btu/h · Ducted82%2.339.552,50018.511.7CEE 25CEE 26Xcel321540234494.797%97%90%
3AVW-60F3DAH2Hisense · Hi-ComfortHisense5 tons60,000 Btu/h · Ducted100%2.1010.163,00017.010.5CEE 25CEE 26CEE AdvXcelDOE321661825388.6100%67%99%
4CHV6-RS60URBMHHCooper & HunterCooper&Hunter5 tons60,000 Btu/h · Ducted100%2.1010.163,00017.010.5CEE 25CEE 26CEE AdvXcelDOE321702655888.6100%67%99%
5AUWR-60U3TH5HISENSE · Hi-PRO HDwith ducted air handler AUH-60UX3TEH3Hisense5 tons57,000 Btu/h · Ducted75%2.429.042,50019.011.0CEE 25CEE 26XcelES CC1121480209888.593%98%74%
6AUWR-6024PHISENSE · Hi-PRO HDwith ducted air handler AUH-6024Also listed as AOH-60U3T24PHisense5 tons57,000 Btu/h · Ducted74%2.469.042,00019.011.0CEE 25CEE 26XcelES CC1721485537988.291%100%74%
7AM060FCMDCG1SAMSUNG · DVM S MiniSamsung5 tons60,000 Btu/h · Ducted85%2.0410.556,25019.011.7CEE 25CEE 26XcelES CC321601631684.398%55%99%
8VPD060H6M-5PLENNOX · DVM S MiniLennox5 tons60,000 Btu/h · Ducted85%2.0410.556,25019.011.7CEE 25CEE 26XcelES CC321605451284.398%55%99%
927VNA360A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAACarrier5 tons58,000 Btu/h · Ducted74%2.189.044,50020.012.5CEE 25CEE 26XcelES CC19721593148482.592%82%74%
103TXK2260AF00HAATrane · TraneAlso listed as 3TVHS060SF000AATrane5 tons60,000 Btu/h · Ducted82%2.0011.053,00016.811.5CEE 25CEE 26Xcel221845102581.897%49%100%