Both views use the same certified data. This device remembers your choice.
BlueRidge vs Rheem heat pumps
Measured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings. BlueRidge has 194 outdoor models, Rheem has 346 outdoor models. They share hardware: 142 equipment families appear under both names.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BlueRidge
- Rheem
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BlueRidge | Rheem |
|---|---|---|
| Efficiency index | 57% (higher)median — · 10th ranked | 50% (higher)median — · 20th ranked |
| COP at 5°F | 57%median 2.00 · 13th ranked | 59%median 2.06 · 11th ranked |
| Capacity retention at 5°F | 55% (higher)median 74% · 12th ranked | 49% (higher)median 65% · 19th ranked |
| HSPF2 | 60% (higher)median 9.5 · 9th ranked | 44% (higher)median 7.5 · 21st ranked |
| SEER2 | 58% (higher)median 19.0 · 9th ranked | 42% (higher)median 15.2 · 24th ranked |
| EER2 | 54% (higher)median 11.9 · 15th ranked | 41% (higher)median 10.6 · 24th ranked |
| Heating capacity at 5°F | 57% (higher)median 19,000 Btu/h · 11th ranked | 49% (higher)median 19,650 Btu/h · 19th ranked |
| Outdoor models | 194 | 346 |
| AHRI certifications | 1,700 | 26,750 |
Share of models meeting each standard
| Standard | BlueRidge | Rheem |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 75.3%146 models | 36.4%126 models |
| CEE 2026 Tier 1 (Split ASHP) | 73.2%142 models | 34.7%120 models |
| CEE Advanced Tier (Split ASHP) | 3.6%7 models | 1.7%6 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 68%132 models | 34.4%119 models |
| DOE Cold Climate Heat Pump Challenge | 3.6%7 models | 1.7%6 models |
| ENERGY STAR Cold Climate | 64.4%125 models | 33.2%115 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BlueRidge
- Rheem
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BlueRidge | Rheem |
|---|---|---|
| Ducted, up to 1.5 tons | 29 · index 70% | 33 · index 56% |
| Ducted, 2 tons | 21 · index 59% | 36 · index 42% |
| Ducted, 2.5 to 3 tons | 38 · index 56% | 91 · index 46% |
| Ducted, 3.5 to 4.5 tons | 36 · index 60% | 122 · index 49% |
| Ducted, 5 tons and up | 5 · index 64% | 32 · index 45% |
| Non-ducted, up to 1.5 tons | 74 · index 55% | 39 · index 60% |
| Non-ducted, 2 tons | 17 · index 51% | 9 · index 55% |
| Non-ducted, 2.5 to 3 tons | 26 · index 51% | 18 · index 55% |
| Non-ducted, 3.5 to 4.5 tons | 20 · index 47% | 12 · index 49% |
| Non-ducted, 5 tons and up | 2 · index 59% | 2 · index 43% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BlueRidgeCold-climate score, best model | RheemCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 93.7(50 is the typical model of its size class)BMS626HHYCwith ducted air handler BMC6LCD24 of 29 models qualify · AHRI 215853938 | 93.7(50 is the typical model of its size class)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I20 of 33 models qualify · AHRI 215864373 |
| Ducted, 2 tons | 85.8(50 is the typical model of its size class)BMS2421HHYCwith ducted air handler BMC24HCDAlso listed as BXS5A24UC018 of 22 models qualify · AHRI 215853945 | 85.8(50 is the typical model of its size class)ML24HP230NEXH-Owith ducted air handler ML24HP230HSDUC-I17 of 35 models qualify · AHRI 215864380 |
| Ducted, 2.5 to 3 tons | 83.5(50 is the typical model of its size class)BMS36HHUYCwith ducted air handler BMS36HCDAlso listed as BXL2A36UC022 of 37 models qualify · AHRI 215853961 | 94.3(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ29 of 91 models qualify · AHRI 218029736 |
| Ducted, 3.5 to 4.5 tons | 83.9(50 is the typical model of its size class)BNG3Z60UCMwith ducted air handler BNGFZ60DH0Also listed as BNG3Z60UCN29 of 36 models qualify · AHRI 217992607 | 95.2(50 is the typical model of its size class) (higher)RD18AY48AJVCwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZ35 of 123 models qualify · AHRI 218827549 |
| Ducted, 5 tons and up | None on this board (0 of 5 models qualify) | 78.1(50 is the typical model of its size class)RP17AY60AJVCwith indoor coil RCFY6024STANM and furnace R801V1255A24UHNAlso sold as SURE SP17AY60AJVC2 of 32 models qualify · AHRI 218160560 |
| Non-ducted, up to 1.5 tons | 97.0(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC053 of 74 models qualify · AHRI 215853901 | 94.9(50 is the typical model of its size class)ML06HP230NEXH-Owith ductless indoor unit ML06HP2301WYCAS-I30 of 39 models qualify · AHRI 215864386 |
| Non-ducted, 2 tons | 90.1(50 is the typical model of its size class)BMS2421HHYCwith ductless indoor unit BMC24CCAlso listed as BXS5A24UC014 of 17 models qualify · AHRI 215853933 | 90.1(50 is the typical model of its size class)ML24HP230NEXH-Owith ductless indoor unit ML24HP230STDCAS-I9 of 9 models qualify · AHRI 215864372 |
| Non-ducted, 2.5 to 3 tons | 89.4(50 is the typical model of its size class)BMS36HHUYCwith ductless indoor unit BMS36FCCAlso listed as BXL2A36UC021 of 26 models qualify · AHRI 215853964 | 89.4(50 is the typical model of its size class)ML36HP230LCMH-Owith ductless indoor unit ML36HP230FLO-I15 of 18 models qualify · AHRI 215864403 |
| Non-ducted, 3.5 to 4.5 tons | 73.6(50 is the typical model of its size class)BMMZ48HHCAlso listed as BXM3A48UC017 of 20 models qualify · AHRI 215853990 | 73.6(50 is the typical model of its size class)ML48HP230MULH-O*Also listed as ML48HP230MULH - O11 of 12 models qualify · AHRI 216623576 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | BlueRidgeAll-around score, best model | RheemAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 95.1(50 is the typical model of its size class)BMS626HHYCwith ducted air handler BMC6LCD29 of 29 models have all five ratings · AHRI 215853938 | 95.1(50 is the typical model of its size class)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I33 of 33 models have all five ratings · AHRI 215864373 |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class)BMS2423YCwith ducted air handler BMC24HCDAlso listed as BXS3A24SC021 of 21 models have all five ratings · AHRI 215853924 | 78.9(50 is the typical model of its size class)ML24HP230NEX-Owith ducted air handler ML24HP230HSDUC-I33 of 33 models have all five ratings · AHRI 215864360 |
| Ducted, 2.5 to 3 tons | 83.9(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC037 of 37 models have all five ratings · AHRI 215853986 | 92.7(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ69 of 92 models have all five ratings · AHRI 218029736 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class)BMMZ48CAlso listed as BXM1A48SC037 of 37 models have all five ratings · AHRI 215853977 | 86.4(50 is the typical model of its size class) (higher)RD18AY48AJVCwith ducted air handler L(E,G)M60IJ71 of 118 models have all five ratings · AHRI 218029742 |
| Ducted, 5 tons and up | 67.2(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-5 of 5 models have all five ratings · AHRI 216371909 | 70.6(50 is the typical model of its size class) (higher)RP17AY60AJVCwith ducted air handler RH2TY6024STANNAlso sold as SURE SP17AY60AJVC24 of 38 models have all five ratings · AHRI 218160613 |
| Non-ducted, up to 1.5 tons | 96.6(50 is the typical model of its size class) (higher)BMS626HHYCwith ductless indoor unit BMC6HHYWAlso listed as BXS5A06UC072 of 74 models have all five ratings · AHRI 215853901 | 94.5(50 is the typical model of its size class)ML06HP230NEXH-Owith ductless indoor unit ML06HP230NEX-I38 of 39 models have all five ratings · AHRI 215864338 |
| Non-ducted, 2 tons | 87.8(50 is the typical model of its size class) (higher)BMS2423YCwith ductless indoor unit BMC24HHYWAlso listed as BXS3A24SC016 of 17 models have all five ratings · AHRI 215853900 | 78.3(50 is the typical model of its size class)ML24HP230CALH-Owith ductless indoor unit ML24HP230CALH-I8 of 8 models have all five ratings · AHRI 215864348 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class)BMMZ36HHCAlso listed as BXM3A36UC026 of 26 models have all five ratings · AHRI 215853985 | 78.8(50 is the typical model of its size class)ML36HP230MULH-O*Also listed as ML36HP230MULH - O18 of 19 models have all five ratings · AHRI 216623571 |
| Non-ducted, 3.5 to 4.5 tons | 75.4(50 is the typical model of its size class)BMMZ48HHCAlso listed as BXM3A48UC020 of 20 models have all five ratings · AHRI 215853988 | 75.4(50 is the typical model of its size class)ML48HP230MULH-O*Also listed as ML48HP230MULH - O12 of 12 models have all five ratings · AHRI 216623574 |
| Non-ducted, 5 tons and up | 59.0(50 is the typical model of its size class)BMMZ60CAlso listed as BXM1A60SC02 of 2 models have all five ratings · AHRI 215853994 | 59.0(50 is the typical model of its size class)ML55HP230MUL-O*2 of 2 models have all five ratings · AHRI 216623550 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BlueRidge | Rheem |
|---|---|---|
| COP at 5°F | beats 99% · 2.51BMS1226YCAlso listed as BXS3A12SC0Non-ducted, up to 1.5 tons | beats 100% · 3.08RP15AY48AJ2NDucted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 100% · 150%BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons | beats 100% · 150%ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 100% · 15.6BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons | beats 100% · 15.6ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| SEER2 | beats 100% · 35.0BMS635SHYCAlso listed as BXS6A06UC0Non-ducted, up to 1.5 tons | beats 100% · 35.0ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| EER2 | beats 99% · 18.0BMS626HHYCAlso listed as BXS5A06UC0Non-ducted, up to 1.5 tons | beats 99% · 17.4ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 22,600 Btu/hBMS1826SHYCAlso listed as BXS6A18UC0Non-ducted, up to 1.5 tons | beats 100% · 35,800 Btu/hRP15AY30AJ2NDucted, 2 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- BlueRidge (median, middle 50%)
- Rheem (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BlueRidge, 47°F | 175 | 100% | 100% | 100% | 100% | 100% |
| BlueRidge, 17°F | 175 | 64% | 68% | 74% | 82% | 88% |
| BlueRidge, 5°F | 175 | 57% | 60% | 66% | 78% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BlueRidge, 47°F | 175 | 2.88 | 3.07 | 3.23 | 3.47 | 3.59 |
| BlueRidge, 17°F | 175 | 2.03 | 2.19 | 2.33 | 2.41 | 2.61 |
| BlueRidge, 5°F | 175 | 1.83 | 1.96 | 2 | 2.14 | 2.31 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 100% | 100% | 100% | 100% | 100% |
| Rheem, 17°F | 118 | 63% | 67% | 73% | 82% | 90% |
| Rheem, 5°F | 118 | 57% | 62% | 70% | 79% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 2.87 | 2.97 | 3.17 | 3.44 | 3.61 |
| Rheem, 17°F | 118 | 2.11 | 2.24 | 2.38 | 2.48 | 2.61 |
| Rheem, 5°F | 118 | 1.9 | 2 | 2 | 2.1 | 2.22 |
Source: NEEP ccASHP list · as of