Skip to content

BOREAL vs Innova SRL heat pumps

Measured against models of the same size and duct type, BOREAL scores higher on 6 of the 6 ratings. BOREAL has 50 outdoor models, Innova SRL has 49 outdoor models. BOREAL and Innova SRL have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BOREAL and Innova SRL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BOREAL scores higher on 6 of the 6 ratings.
  • BOREAL
  • Innova SRL
  • Other ranked manufacturers
BOREALInnova S…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBOREALInnova SRL
Efficiency index53% (higher)median —25% (higher)median —
COP at 5°F43% (higher)median 1.9513% (higher)median 1.75
Capacity retention at 5°F59% (higher)median 78%46% (higher)median 72%
HSPF241% (higher)median 9.029% (higher)median 8.5
SEER259% (higher)median 19.013% (higher)median 14.4
EER256% (higher)median 11.927% (higher)median 11.2
Heating capacity at 5°F57% (higher)median 17,000 Btu/h12% (higher)median 6,500 Btu/h
Outdoor models5049
AHRI certifications14549

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBOREALInnova SRL
CEE 2025 Tier 1 (Split ASHP)86%43 models0%0 models
CEE 2026 Tier 1 (Split ASHP)86%43 models0%0 models
CEE Advanced Tier (Split ASHP)6%3 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)88%44 models0%0 models
DOE Cold Climate Heat Pump Challenge6%3 models0%0 models
ENERGY STAR Cold Climate60%30 models42.9%21 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • BOREAL
  • Innova SRL
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBOREALInnova SRL
Ducted, up to 1.5 tons9 · index 65%29 · index 25%
Ducted, 2 tons6 · index 58%None
Ducted, 2.5 to 3 tons12 · index 53%None
Ducted, 3.5 to 4.5 tons6 · index 68%None
Non-ducted, up to 1.5 tons23 · index 47%20 · index 24%
Non-ducted, 2 tons6 · index 50%None
Non-ducted, 2.5 to 3 tons6 · index 43%None
Non-ducted, 3.5 to 4.5 tons2 · index 39%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBOREALCold-climate score, best modelInnova SRLCold-climate score, best model
Ducted, up to 1.5 tons70.5(50 is the typical model of its size class) (higher)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA8 of 9 models qualify · AHRI 21556026744.4(50 is the typical model of its size class)VRVL50W0TUCAlso listed as VRVL50W0EUC, VRVL50WOEUC, VRVL50WOTUC23 of 29 models qualify · AHRI 217753721
Ducted, 2 tons76.2(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 7 models qualify · AHRI 215420685No models in this size class
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH7 of 11 models qualify · AHRI 217463586No models in this size class
Ducted, 3.5 to 4.5 tons85.1(50 is the typical model of its size class)ENX60HPJ132OAwith ducted air handler ENX60HPJ132IA5 of 6 models qualify · AHRI 215420683No models in this size class
Non-ducted, up to 1.5 tons64.7(50 is the typical model of its size class) (higher)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA21 of 23 models qualify · AHRI 21542478328.2(50 is the typical model of its size class)APP10N3H2Also listed as APP10*3*1, APP10*3*2, APE10*3*2, APK10*3*2 and 15 more20 of 20 models qualify · AHRI 218326911
Non-ducted, 2 tons68.5(50 is the typical model of its size class)MUL24HPJ132OA5 of 6 models qualify · AHRI 215424769No models in this size class
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class)MUL36HPJ132OA6 of 6 models qualify · AHRI 215424771No models in this size class
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models qualify · AHRI 215424772No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBOREALAll-around score, best modelInnova SRLAll-around score, best model
Ducted, up to 1.5 tons83.9(50 is the typical model of its size class) (higher)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA9 of 9 models have all five ratings · AHRI 21556026746.7(50 is the typical model of its size class)C5MO09IC1UC29 of 29 models have all five ratings · AHRI 218418649
Ducted, 2 tons68.6(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 6 models have all five ratings · AHRI 215420685No models in this size class
Ducted, 2.5 to 3 tons68.5(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH12 of 12 models have all five ratings · AHRI 217463586No models in this size class
Ducted, 3.5 to 4.5 tons80.0(50 is the typical model of its size class)ENX48HPJ132OAwith ducted air handler ENX48HPJ132IAAlso listed as ENX60HPJ132OA, ARX60HPJ1R32OA6 of 6 models have all five ratings · AHRI 215420684No models in this size class
Non-ducted, up to 1.5 tons79.8(50 is the typical model of its size class) (higher)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA23 of 23 models have all five ratings · AHRI 21542478323.7(50 is the typical model of its size class)APP10N3H2Also listed as APP10*3*1, APP10*3*2, APE10*3*2, APK10*3*2 and 15 more20 of 20 models have all five ratings · AHRI 218326911
Non-ducted, 2 tons73.1(50 is the typical model of its size class)KUL24HPJ132OAwith ductless indoor unit KUL24HPJ132IA5 of 6 models have all five ratings · AHRI 215424817No models in this size class
Non-ducted, 2.5 to 3 tons71.2(50 is the typical model of its size class)MUL30HPJ132OA6 of 6 models have all five ratings · AHRI 215424770No models in this size class
Non-ducted, 3.5 to 4.5 tons67.8(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models have all five ratings · AHRI 215424772No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBOREALInnova SRL
COP at 5°Fbeats 87% · 2.10MUL36HPJ132OANon-ducted, 2.5 to 3 tonsbeats 79% · 2.16C5MO09IC1UCDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 94% · 100%ENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 66% · 81%APP10N3H2Also listed as APP10*3*1, APP10*3*2, APE10*3*2, APK10*3*2 and 15 moreNon-ducted, up to 1.5 tons
HSPF2beats 91% · 10.5ENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 97% · 12.6C5MO09IC1UCDucted, up to 1.5 tons
SEER2beats 99% · 22.5KUL18HPJ132OAAlso listed as NOV18HPJ132OADucted, up to 1.5 tonsbeats 46% · 15.8C3MS15CI3UCAlso listed as C3NS15CI3UC, C3NS15IC3UCDucted, up to 1.5 tons
EER2beats 97% · 14.2KUL09HPJ132OAAlso listed as NOV09HPJ132OADucted, up to 1.5 tonsbeats 50% · 11.7VRVB90W0EUCAlso listed as VRVB90W0TUCDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 41% · 8,300 Btu/hVRVB90W0EUCAlso listed as VRVB90W0TUCDucted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BOREAL vs Innova SRL: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,310 models (46.4% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BOREAL (median, middle 50%)
  • Innova SRL (median, middle 50%)
Heating capacity, % of its 47°F maximum69%48%COP at maximum capacity2.001.75

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,310100%100%100%100%100%
All rated models, 17°F6,31064%69%74%83%91%
All rated models, 5°F6,31057%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3102.833.243.483.66
All rated models, 17°F6,31022.132.292.422.61
All rated models, 5°F6,3101.81.8722.12.24
BOREAL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F45100%100%100%100%100%
BOREAL, 17°F4568%75%82%87%96%
BOREAL, 5°F4559%63%69%76%98%
BOREAL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F452.923.173.283.373.47
BOREAL, 17°F452.062.12.32.42.57
BOREAL, 5°F451.81.8522.072.14
Innova SRL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Innova SRL, 47°F20100%100%100%100%100%
Innova SRL, 17°F2065%65%65%65%65%
Innova SRL, 5°F2048%48%48%48%48%
Innova SRL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Innova SRL, 47°F203.263.263.263.263.26
Innova SRL, 17°F202.242.242.242.242.24
Innova SRL, 5°F201.751.751.751.751.75

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy