Skip to content

BOREAL vs Senville heat pumps

Measured against models of the same size and duct type, Senville scores higher on 6 of the 6 ratings. BOREAL has 50 outdoor models, Senville has 34 outdoor models. BOREAL has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BOREAL and Senville on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Senville scores higher on 6 of the 6 ratings.
  • BOREAL
  • Senville
  • Other ranked manufacturers
BOREALSenville

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBOREALSenville
Efficiency index53%median —65%median — · 2nd ranked
COP at 5°F43%median 1.9557%median 2.00 · 13th ranked
Capacity retention at 5°F59%median 78%69%median 91% · 1st ranked
HSPF241%median 9.073%median 10.0 · 2nd ranked
SEER259%median 19.069%median 21.1 · 1st ranked
EER256%median 11.962%median 12.0 · 6th ranked
Heating capacity at 5°F57%median 17,000 Btu/h66%median 21,200 Btu/h · 3rd ranked
Outdoor models5034
AHRI certifications14564

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBOREALSenville
CEE 2025 Tier 1 (Split ASHP)86%43 models82.4%28 models
CEE 2026 Tier 1 (Split ASHP)86%43 models79.4%27 models
CEE Advanced Tier (Split ASHP)6%3 models2.9%1 models
Xcel Energy Colorado cold-climate ASHP (2025)88%44 models73.5%25 models
DOE Cold Climate Heat Pump Challenge6%3 models2.9%1 models
ENERGY STAR Cold Climate60%30 models70.6%24 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • BOREAL
  • Senville
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBOREALSenville
Ducted, up to 1.5 tons9 · index 65%4 · index 78%
Ducted, 2 tons6 · index 58%4 · index 77%
Ducted, 2.5 to 3 tons12 · index 53%5 · index 69%
Ducted, 3.5 to 4.5 tons6 · index 68%6 · index 62%
Non-ducted, up to 1.5 tons23 · index 47%15 · index 64%
Non-ducted, 2 tons6 · index 50%2 · index 56%
Non-ducted, 2.5 to 3 tons6 · index 43%5 · index 48%
Non-ducted, 3.5 to 4.5 tons2 · index 39%2 · index 67%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBOREALCold-climate score, best modelSenvilleCold-climate score, best model
Ducted, up to 1.5 tons70.7(50 is the typical model of its size class)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA8 of 9 models qualify · AHRI 21556026780.6(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models qualify · AHRI 215735300
Ducted, 2 tons76.3(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 7 models qualify · AHRI 21542068585.8(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ducted air handler SENA-24HF-IDG4 of 4 models qualify · AHRI 215735303
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH7 of 11 models qualify · AHRI 21746358682.7(50 is the typical model of its size class) (higher)SENA-36HF-MOA4 of 5 models qualify · AHRI 215735318
Ducted, 3.5 to 4.5 tons85.1(50 is the typical model of its size class) (higher)ENX60HPJ132OAwith ducted air handler ENX60HPJ132IA5 of 6 models qualify · AHRI 21542068382.6(50 is the typical model of its size class)SENA-48HF-MOA4 of 6 models qualify · AHRI 215735321
Non-ducted, up to 1.5 tons64.7(50 is the typical model of its size class)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA21 of 23 models qualify · AHRI 21542478397.0(50 is the typical model of its size class) (higher)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG9 of 15 models qualify · AHRI 215735294
Non-ducted, 2 tons68.5(50 is the typical model of its size class)MUL24HPJ132OA5 of 6 models qualify · AHRI 21542476990.1(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ductless indoor unit SENA-24HF-ICG2 of 2 models qualify · AHRI 215735307
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class)MUL36HPJ132OA6 of 6 models qualify · AHRI 21542477178.3(50 is the typical model of its size class) (higher)SENA-36HF-MOA3 of 5 models qualify · AHRI 215735319
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models qualify · AHRI 21542477273.6(50 is the typical model of its size class) (higher)SENA-48HF-MOA2 of 2 models qualify · AHRI 215735322

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBOREALAll-around score, best modelSenvilleAll-around score, best model
Ducted, up to 1.5 tons84.0(50 is the typical model of its size class)KUL09HPJ132OAwith ducted air handler DUC09HPJ132IAAlso listed as NOV09HPJ132OA9 of 9 models have all five ratings · AHRI 21556026787.1(50 is the typical model of its size class) (higher)SENA-09HF-OGwith ducted air handler SENA-09HF-IDG4 of 4 models have all five ratings · AHRI 215735300
Ducted, 2 tons68.6(50 is the typical model of its size class)ENX24HPJ132OAwith ducted air handler ENX24HPJ132IA6 of 6 models have all five ratings · AHRI 21542068590.0(50 is the typical model of its size class) (higher)SENE-24EL-OHwith ducted air handler SENE-24EL-IHH4 of 4 models have all five ratings · AHRI 218069801
Ducted, 2.5 to 3 tons68.5(50 is the typical model of its size class)ENX36HPJ132OAwith ducted air handler ENXE36HPJ1R32AH12 of 12 models have all five ratings · AHRI 21746358683.9(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 215735318
Ducted, 3.5 to 4.5 tons80.0(50 is the typical model of its size class)ENX48HPJ132OAwith ducted air handler ENX48HPJ132IAAlso listed as ENX60HPJ132OA, ARX60HPJ1R32OA6 of 6 models have all five ratings · AHRI 21542068484.3(50 is the typical model of its size class) (higher)SENA-48HF-MOA6 of 6 models have all five ratings · AHRI 215735321
Non-ducted, up to 1.5 tons79.8(50 is the typical model of its size class)KUL09HPL132OAwith ductless indoor unit KUL09HPL132IAAlso listed as NOV09HPL132OA23 of 23 models have all five ratings · AHRI 21542478396.6(50 is the typical model of its size class) (higher)SENA-06HF-OGwith ductless indoor unit SENA-06HF-IGG13 of 15 models have all five ratings · AHRI 215735294
Non-ducted, 2 tons73.1(50 is the typical model of its size class)KUL24HPJ132OAwith ductless indoor unit KUL24HPJ132IA5 of 6 models have all five ratings · AHRI 21542481778.3(50 is the typical model of its size class) (higher)SENA-24HF-OGwith ductless indoor unit SENA-24HF-IGG2 of 2 models have all five ratings · AHRI 215735298
Non-ducted, 2.5 to 3 tons71.2(50 is the typical model of its size class)MUL30HPJ132OA6 of 6 models have all five ratings · AHRI 21542477078.8(50 is the typical model of its size class) (higher)SENA-36HF-MOA5 of 5 models have all five ratings · AHRI 215735317
Non-ducted, 3.5 to 4.5 tons67.8(50 is the typical model of its size class)MUL42HPJ132OA2 of 2 models have all five ratings · AHRI 21542477275.4(50 is the typical model of its size class) (higher)SENA-48HF-MOA2 of 2 models have all five ratings · AHRI 215735320

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBOREALSenville
COP at 5°Fbeats 87% · 2.10MUL36HPJ132OANon-ducted, 2.5 to 3 tonsbeats 97% · 2.40SENA-06HF-OGNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 94% · 100%ENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 97% · 113%SENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tons
HSPF2beats 91% · 10.5ENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 99% · 14.8SENA-06HF-OGNon-ducted, up to 1.5 tons
SEER2beats 99% · 22.5KUL18HPJ132OAAlso listed as NOV18HPJ132OADucted, up to 1.5 tonsbeats 100% · 25.0SENE-24EL-OHDucted, 2 tons
EER2beats 97% · 14.2KUL09HPJ132OAAlso listed as NOV09HPJ132OADucted, up to 1.5 tonsbeats 99% · 18.0SENA-06HF-OGNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hENX60HPJ132OADucted, 3.5 to 4.5 tonsbeats 99% · 22,600 Btu/hSENE-18EL-IHHAlso listed as SENE-18EL-OHNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BOREAL vs Senville: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BOREAL (median, middle 50%)
  • Senville (median, middle 50%)
Heating capacity, % of its 47°F maximum69%76%COP at maximum capacity2.002.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
BOREAL: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F45100%100%100%100%100%
BOREAL, 17°F4568%75%82%87%96%
BOREAL, 5°F4559%63%69%76%96%
BOREAL: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BOREAL, 47°F452.923.113.283.373.47
BOREAL, 17°F452.062.12.32.42.57
BOREAL, 5°F451.81.8522.072.14
Senville: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Senville, 47°F30100%100%100%100%100%
Senville, 17°F3069%74%78%84%86%
Senville, 5°F3060%65%76%81%82%
Senville: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Senville, 47°F302.913.093.213.433.57
Senville, 17°F302.082.142.312.52.62
Senville, 5°F301.841.922.092.34

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter