Measured against models of the same size and duct type, KLIMAIRE scores higher on 3 of the 6 ratings. Century has 59 outdoor models, KLIMAIRE has 25 outdoor models. Century and KLIMAIRE have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Century and KLIMAIRE on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KLIMAIRE scores higher on 3 of the 6 ratings.
  • Century
  • KLIMAIRE
  • Other ranked manufacturers
CenturyKLIMAIRE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCenturyKLIMAIRE
Efficiency index50%median —55%median —
COP at 5°F50%median 1.9850%median 2.00
Capacity retention at 5°F49% (higher)median 63%48% (higher)median 72%
HSPF252%median 8.160%median 10.0
SEER245%median 15.261%median 21.2
EER253% (higher)median 11.452% (higher)median 12.0
Heating capacity at 5°F49%median 19,000 Btu/h55%median 18,900 Btu/h
Outdoor models5925
AHRI certifications1,14745

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCenturyKLIMAIRE
CEE 2025 Tier 1 (Split ASHP)44.1%26 models76%19 models
CEE 2026 Tier 1 (Split ASHP)44.1%26 models76%19 models
CEE Advanced Tier (Split ASHP)3.4%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)40.7%24 models72%18 models
DOE Cold Climate Heat Pump Challenge3.4%2 models0%0 models
ENERGY STAR Cold Climate32.2%19 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 8 groups where both have models
  • Century
  • KLIMAIRE
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsNon-ducted, 5 tons and up2.0585 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCenturyKLIMAIRE
Ducted, up to 1.5 tons8 · index 72%2 · index 76%
Ducted, 2 tons13 · index 41%1 · index 65%
Ducted, 2.5–3 tons14 · index 42%3 · index 77%
Ducted, 3.5–4.5 tons21 · index 39%3 · index 84%
Ducted, 5 tons and upNone1 · index 63%
Non-ducted, up to 1.5 tons6 · index 77%10 · index 47%
Non-ducted, 2 tons1 · index 76%3 · index 40%
Non-ducted, 2.5–3 tons3 · index 67%7 · index 45%
Non-ducted, 3.5–4.5 tons2 · index 67%4 · index 53%
Non-ducted, 5 tons and upNone1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCenturyCold-climate score, best modelKLIMAIRECold-climate score, best model
Ducted, up to 1.5 tons86.6(50 is the typical model of its size class) (higher)A-VXP18SA-1with ducted air handler WXP18SA6 of 8 models qualify · AHRI 21748241272.6(50 is the typical model of its size class)KMIR319-H221-42 of 2 models qualify · AHRI 217489269
Ducted, 2 tons85.7(50 is the typical model of its size class) (higher)A-VHP24SA-1with ducted air handler B-VHP24DA-17 of 14 models qualify · AHRI 21748247048.6(50 is the typical model of its size class)KMIR427-H225-41 of 1 models qualify · AHRI 217489272
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)A-VHP365A-14 of 13 models qualify · AHRI 21842516682.5(50 is the typical model of its size class)KMHR536-H224-43 of 3 models qualify · AHRI 217489290
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)A-VHP486A-18 of 21 models qualify · AHRI 21842516982.7(50 is the typical model of its size class)KMHR648-H224-43 of 3 models qualify · AHRI 217489293
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons96.7(50 is the typical model of its size class) (higher)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models qualify · AHRI 21842515368.6(50 is the typical model of its size class)KMIP218-H225-47 of 10 models qualify · AHRI 218067072
Non-ducted, 2 tons89.4(50 is the typical model of its size class) (higher)A-VHP24SA-1with ductless indoor unit B-VHP24CA-11 of 1 models qualify · AHRI 21748246841.1(50 is the typical model of its size class)KMIR427-H225-42 of 3 models qualify · AHRI 217489271
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class) (higher)A-VHP365A-13 of 3 models qualify · AHRI 21842516772.6(50 is the typical model of its size class)KMHR536-H224-45 of 7 models qualify · AHRI 217489291
Non-ducted, 3.5–4.5 tons73.4(50 is the typical model of its size class) (higher)A-VHP486A-12 of 2 models qualify · AHRI 21842517069.9(50 is the typical model of its size class)KMHR660-H218-44 of 4 models qualify · AHRI 217489297
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCenturyAll-around score, best modelKLIMAIREAll-around score, best model
Ducted, up to 1.5 tons86.5(50 is the typical model of its size class) (higher)A-VHP09SA-1with ducted air handler B-VHP09DA-18 of 8 models have all five ratings · AHRI 21748245877.4(50 is the typical model of its size class)KMHR319-H221-42 of 2 models have all five ratings · AHRI 217489284
Ducted, 2 tons78.4(50 is the typical model of its size class) (higher)A-VHP24SA-1with ducted air handler B-VHP24DA-112 of 12 models have all five ratings · AHRI 21748247064.5(50 is the typical model of its size class)KMIR427-H225-41 of 1 models have all five ratings · AHRI 217489272
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)A-VHP365A-113 of 13 models have all five ratings · AHRI 21842516683.6(50 is the typical model of its size class)KMHR536-H224-43 of 3 models have all five ratings · AHRI 217489290
Ducted, 3.5–4.5 tons83.9(50 is the typical model of its size class)A-VHP486A-122 of 22 models have all five ratings · AHRI 21842516985.1(50 is the typical model of its size class) (higher)KMIR648-H224-43 of 3 models have all five ratings · AHRI 217489278
Ducted, 5 tons and up66.7(50 is the typical model of its size class) (higher)HSA1460S1-**Awith ducted air handler HMA60VX1*-1 of 1 models have all five ratings · AHRI 21637048562.5(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489281
Non-ducted, up to 1.5 tons96.2(50 is the typical model of its size class) (higher)A-VHP06SA-1with ductless indoor unit B-VHP06SA-16 of 6 models have all five ratings · AHRI 21842515372.2(50 is the typical model of its size class)KMIP218-H225-410 of 10 models have all five ratings · AHRI 218067072
Non-ducted, 2 tons76.4(50 is the typical model of its size class) (higher)A-VHP24SA-1with ductless indoor unit B-VHP24SA-11 of 1 models have all five ratings · AHRI 21842515756.7(50 is the typical model of its size class)KMIR427-H225-43 of 3 models have all five ratings · AHRI 217489271
Non-ducted, 2.5–3 tons78.3(50 is the typical model of its size class) (higher)A-VHP365A-13 of 3 models have all five ratings · AHRI 21842516566.3(50 is the typical model of its size class)KMHR536-H224-47 of 7 models have all five ratings · AHRI 217489289
Non-ducted, 3.5–4.5 tons75.6(50 is the typical model of its size class) (higher)A-VHP486A-12 of 2 models have all five ratings · AHRI 21842516862.6(50 is the typical model of its size class)KMHR660-H218-44 of 4 models have all five ratings · AHRI 217489295
Non-ducted, 5 tons and upNo models in this size class32.5(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489280

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCenturyKLIMAIRE
COP at 5°Fbeats 98% · 2.75SHP1448S1ADucted, 3.5–4.5 tonsbeats 89% · 2.25KMIR319-H221-4Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 126%A-VHP09SA-1Non-ducted, up to 1.5 tonsbeats 95% · 104%KMHR536-H224-4Non-ducted, 2.5–3 tons
HSPF2beats 99% · 14.8A-VHP06SA-1Non-ducted, up to 1.5 tonsbeats 99% · 11.0KMHR648-H224-4Ducted, 3.5–4.5 tons
SEER2beats 100% · 27.0A-ZHP15SA-1Ducted, up to 1.5 tonsbeats 96% · 20.4KMIR648-H224-4Ducted, 3.5–4.5 tons
EER2beats 99% · 18.0A-VHP06SA-1Non-ducted, up to 1.5 tonsbeats 85% · 13.0KMHR319-H221-4Ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 19,600 Btu/hA-VXP18SA-1Ducted, up to 1.5 tonsbeats 94% · 37,400 Btu/hKMHR536-H224-4Non-ducted, 2.5–3 tons