Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CIAC vs OLMO heat pumps
Measured against models of the same size and duct type, OLMO scores higher on 5 of the 6 ratings. CIAC has 3 outdoor models, OLMO has 11 outdoor models. CIAC and OLMO have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CIAC
- OLMO
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CIAC | OLMO |
|---|---|---|
| Efficiency index | 38%median — | 43%median — |
| COP at 5°F | 83% (higher)median 2.13 | 45% (higher)median 1.98 |
| Capacity retention at 5°F | 16%median 67% | 40%median 74% |
| HSPF2 | 11%median 8.0 | 33%median 9.0 |
| SEER2 | 22%median 17.0 | 45%median 20.0 |
| EER2 | 14%median 9.5 | 50%median 12.0 |
| Heating capacity at 5°F | 17%median 6,700 Btu/h | 41%median 18,000 Btu/h |
| Outdoor models | 3 | 11 |
| AHRI certifications | 4 | 17 |
Share of models meeting each standard
| Standard | CIAC | OLMO |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3%1 models | 90.9%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 33.3%1 models | 81.8%9 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 54.5%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 36.4%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CIAC
- OLMO
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CIAC | OLMO |
|---|---|---|
| Non-ducted, up to 1.5 tons | 1 · index 38% | 6 · index 43% |
| Non-ducted, 2.5–3 tons | 2 · index — | 3 · index 47% |
| Non-ducted, 2 tons | None | 1 · index 34% |
| Non-ducted, 3.5–4.5 tons | None | 1 · index 44% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CIACCold-climate score, best model | OLMOCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 69.5(50 is the typical model of its size class)OS-RMS18-230VO2 of 6 models qualify · AHRI 217739001 |
| Non-ducted, 2 tons | No models in this size class | 38.8(50 is the typical model of its size class)OS-SR24-230VOwith ductless indoor unit OS-A24SRW-230VI1 of 1 models qualify · AHRI 218752476 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 53.7(50 is the typical model of its size class)OS-RMS36-230VO2 of 3 models qualify · AHRI 217739004 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 16.4(50 is the typical model of its size class)OS-RMS42-230VO1 of 1 models qualify · AHRI 217739003 |
All-around best
| Size and duct type | CIACAll-around score, best model | OLMOAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 37.8(50 is the typical model of its size class)CPEA12AC1151AOwith ductless indoor unit CPEA12AC1151AH1 of 1 models have all five ratings · AHRI 218814656 | 69.2(50 is the typical model of its size class) (higher)OS-RMS18-230VO6 of 6 models have all five ratings · AHRI 217739001 |
| Non-ducted, 2 tons | No models in this size class | 34.1(50 is the typical model of its size class)OS-SR24-230VOwith ductless indoor unit OS-A24SRW-230VI1 of 1 models have all five ratings · AHRI 218752476 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models have all five ratings) | 64.2(50 is the typical model of its size class)OS-RMS27-230VO3 of 3 models have all five ratings · AHRI 217739002 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 43.7(50 is the typical model of its size class)OS-RMS42-230VO1 of 1 models have all five ratings · AHRI 217739003 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CIAC | OLMO |
|---|---|---|
| COP at 5°F | beats 96% · 2.21PCG817A-X036PHB3CNon-ducted, 2.5–3 tons | beats 100% · 2.53OS-SR18-230VONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 16% · 67%CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 87% · 100%OS-RMS18-230VONon-ducted, up to 1.5 tons |
| HSPF2 | beats 29% · 9.0CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 64% · 10.0OS-RMS18-230VONon-ducted, up to 1.5 tons |
| SEER2 | beats 56% · 22.0CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 75% · 23.0OS-RMS27-230VONon-ducted, 2.5–3 tons |
| EER2 | beats 16% · 10.0CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 80% · 12.9OS-RMS27-230VONon-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 32% · 8,200 Btu/hCPEA12AC1151AONon-ducted, up to 1.5 tons | beats 93% · 18,000 Btu/hOS-RMS18-230VONon-ducted, up to 1.5 tons |