Skip to content

DIRECT AIR vs WHIRLPOOL heat pumps

Measured against models of the same size and duct type, DIRECT AIR scores higher on 6 of the 6 ratings. DIRECT AIR has 57 outdoor models, WHIRLPOOL has 59 outdoor models. DIRECT AIR and WHIRLPOOL have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
DIRECT AIR and WHIRLPOOL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, DIRECT AIR scores higher on 6 of the 6 ratings.
  • DIRECT AIR
  • WHIRLPOOL
  • Other ranked manufacturers
DIRECT A…WHIRLPOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDIRECT AIRWHIRLPOOL
Efficiency index65% (higher)median —26% (higher)median —
COP at 5°F62% (higher)median 2.0041% (higher)median 1.87
Capacity retention at 5°F63% (higher)median 81%21% (higher)median 47%
HSPF272% (higher)median 9.922% (higher)median 7.5
SEER269% (higher)median 20.518% (higher)median 14.3
EER261% (higher)median 12.033% (higher)median 10.6
Heating capacity at 5°F64% (higher)median 20,000 Btu/h22% (higher)median 19,550 Btu/h
Outdoor models5759
AHRI certifications208368

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDIRECT AIRWHIRLPOOL
CEE 2025 Tier 1 (Split ASHP)91.2%52 models1.7%1 models
CEE 2026 Tier 1 (Split ASHP)89.5%51 models0%0 models
CEE Advanced Tier (Split ASHP)1.8%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)80.7%46 models3.4%2 models
DOE Cold Climate Heat Pump Challenge1.8%1 models0%0 models
ENERGY STAR Cold Climate78.9%45 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 5 groups where both have models
  • DIRECT AIR
  • WHIRLPOOL
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDIRECT AIRWHIRLPOOL
Ducted, up to 1.5 tons12 · index 74%2 · index 26%
Ducted, 2 tons6 · index 63%7 · index 25%
Ducted, 2.5 to 3 tons13 · index 69%16 · index 24%
Ducted, 3.5 to 4.5 tons11 · index 66%25 · index 28%
Ducted, 5 tons and up1 · index 63%9 · index 26%
Non-ducted, up to 1.5 tons19 · index 64%None
Non-ducted, 2 tons4 · index 66%None
Non-ducted, 2.5 to 3 tons13 · index 62%None
Non-ducted, 3.5 to 4.5 tons8 · index 55%None
Non-ducted, 5 tons and up1 · index 59%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDIRECT AIRCold-climate score, best modelWHIRLPOOLCold-climate score, best model
Ducted, up to 1.5 tons82.7(50 is the typical model of its size class)DIRM4-18HXPRO28-1Zwith ducted air handler DIRM4-18HP-DU11 of 12 models qualify · AHRI 217447834None on this board (0 of 2 models qualify)
Ducted, 2 tons85.8(50 is the typical model of its size class) (higher)DIRM4-24HXPRO28-1Zwith ducted air handler DIRM4-24HP-DU6 of 6 models qualify · AHRI 21678852775.4(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 7 models qualify · AHRI 218687483
Ducted, 2.5 to 3 tons83.5(50 is the typical model of its size class) (higher)DIRM4-36LCHX-1Zwith ducted air handler DIRM4-36HP-DU11 of 13 models qualify · AHRI 21678853178.4(50 is the typical model of its size class)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR1 of 16 models qualify · AHRI 218687485
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)DIRM4-48HXPRO28-5ZAlso listed as DIRM4-48HXPRO28-6Z11 of 11 models qualify · AHRI 215213809None on this board (0 of 25 models qualify)
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 9 models qualify)
Non-ducted, up to 1.5 tons97.0(50 is the typical model of its size class)DIRM4-06HXPRO28-1Zwith ductless indoor unit DIRM4-06HP-WM15 of 19 models qualify · AHRI 216571371No models in this size class
Non-ducted, 2 tons90.1(50 is the typical model of its size class)DIRM4-24HXPRO28-1Zwith ductless indoor unit DIRM4-24HP-CA4 of 4 models qualify · AHRI 216788526No models in this size class
Non-ducted, 2.5 to 3 tons89.4(50 is the typical model of its size class)DIRM4-36LCHX-1Zwith ductless indoor unit DIRM4-36HP-CF11 of 13 models qualify · AHRI 216571385No models in this size class
Non-ducted, 3.5 to 4.5 tons73.7(50 is the typical model of its size class)DIRM4-48HXPRO28-5ZAlso listed as DIRM4-48HXPRO28-6Z7 of 8 models qualify · AHRI 215213810No models in this size class
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDIRECT AIRAll-around score, best modelWHIRLPOOLAll-around score, best model
Ducted, up to 1.5 tons86.9(50 is the typical model of its size class) (higher)DIRM4-09HXPRO28-1Zwith ducted air handler DIRM4-09HP-DU12 of 12 models have all five ratings · AHRI 21744783035.4(50 is the typical model of its size class)WLP15AY18AJ2Nwith ducted air handler WLH2TY2417STANN2 of 2 models have all five ratings · AHRI 217536709
Ducted, 2 tons78.9(50 is the typical model of its size class) (higher)DIRM4-24DA25-1Zwith ducted air handler DIRM4-24HP-DU6 of 6 models have all five ratings · AHRI 21678852956.5(50 is the typical model of its size class)WLP15AY30AJ2Nwith ducted air handler AE*S+DM36A3J+TDR6 of 6 models have all five ratings · AHRI 218687483
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class) (higher)DIRM4-36HXPRO28-4ZAlso listed as DIRM4-36HXPRO28-5Z13 of 13 models have all five ratings · AHRI 21521380663.5(50 is the typical model of its size class)WLP15AY36AJ2Nwith ducted air handler AE*S+DM36A3J+TDR12 of 16 models have all five ratings · AHRI 218687485
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class) (higher)DIRM4-48DA25-5ZAlso listed as DIRM4-48DA25-6Z11 of 11 models have all five ratings · AHRI 21521379754.7(50 is the typical model of its size class)WLP15AY42AJ2Nwith ducted air handler WLH2TY4824STANN14 of 25 models have all five ratings · AHRI 217619601
Ducted, 5 tons and up63.2(50 is the typical model of its size class) (higher)DIRM4-60DA25-6Z1 of 1 models have all five ratings · AHRI 21833178057.0(50 is the typical model of its size class)WLP15AY60AJ2Nwith ducted air handler WLH2TY6024STANN8 of 10 models have all five ratings · AHRI 217536707
Non-ducted, up to 1.5 tons96.6(50 is the typical model of its size class)DIRM4-06HXPRO28-1Zwith ductless indoor unit DIRM4-06HP-WM19 of 19 models have all five ratings · AHRI 216571371No models in this size class
Non-ducted, 2 tons87.8(50 is the typical model of its size class)DIRM4-24DA25-1Zwith ductless indoor unit DIRM4-24HP-WM4 of 4 models have all five ratings · AHRI 216571370No models in this size class
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class)DIRM4-36HXPRO28-4ZAlso listed as DIRM4-36HXPRO28-5Z13 of 13 models have all five ratings · AHRI 215213805No models in this size class
Non-ducted, 3.5 to 4.5 tons75.5(50 is the typical model of its size class)DIRM4-48HXPRO28-5ZAlso listed as DIRM4-48HXPRO28-6Z8 of 8 models have all five ratings · AHRI 215213808No models in this size class
Non-ducted, 5 tons and up59.0(50 is the typical model of its size class)DIRM4-60DA25-6Z1 of 1 models have all five ratings · AHRI 218331779No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDIRECT AIRWHIRLPOOL
COP at 5°Fbeats 100% · 2.53DIRH3-18HP21-DKONon-ducted, up to 1.5 tonsbeats 98% · 2.73WLP15AY36AJ2NDucted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 98% · 126%DIRM4-09HXPRO28-1ZNon-ducted, up to 1.5 tonsbeats 100% · 127%WLP15AY30AJ2NDucted, 2 tons
HSPF2beats 99% · 14.8DIRM4-06HXPRO28-1ZNon-ducted, up to 1.5 tonsbeats 56% · 7.8WLP15AY60AJ2NDucted, 5 tons and up
SEER2beats 97% · 25.0DIRM4-27DA25-3Z*Also listed as DIRM4-27DA25-4ZNon-ducted, 2.5 to 3 tonsbeats 49% · 16.0WLP15AY42AJ2NDucted, 3.5 to 4.5 tons
EER2beats 99% · 18.0DIRM4-06HXPRO28-1ZNon-ducted, up to 1.5 tonsbeats 69% · 11.7WLP15AY48AJ2NDucted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 98% · 39,500 Btu/hDIRM4-36LCHX-1ZNon-ducted, 2.5 to 3 tonsbeats 100% · 34,600 Btu/hWLP15AY30AJ2NDucted, 2 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy