Both views use the same certified data. This device remembers your choice.
EXNOS vs ForestAir heat pumps
Measured against models of the same size and duct type, ForestAir scores higher on 6 of the 6 ratings. EXNOS has 38 outdoor models, ForestAir has 37 outdoor models. EXNOS and ForestAir have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- EXNOS
- ForestAir
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | EXNOS | ForestAir |
|---|---|---|
| Efficiency index | 33%median — | 64%median — |
| COP at 5°F | 36%median 1.80 | 44%median 2.00 |
| Capacity retention at 5°F | 31%median 70% | 62%median 75% |
| HSPF2 | 43%median 9.5 | 66%median 10.0 |
| SEER2 | 31%median 20.0 | 80%median 23.0 |
| EER2 | 28%median 10.5 | 61%median 12.5 |
| Heating capacity at 5°F | 38%median 9,500 Btu/h | 58%median 18,500 Btu/h |
| Outdoor models | 38 | 37 |
| AHRI certifications | 38 | 64 |
Share of models meeting each standard
| Standard | EXNOS | ForestAir |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 63.2%24 models | 97.3%36 models |
| CEE 2026 Tier 1 (Split ASHP) | 60.5%23 models | 97.3%36 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 2.7%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 50%19 models | 97.3%36 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 2.7%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 51.4%19 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- EXNOS
- ForestAir
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | EXNOS | ForestAir |
|---|---|---|
| Ducted, up to 1.5 tons | None | 5 · index 59% |
| Ducted, 2 tons | None | 3 · index 70% |
| Ducted, 2.5 to 3 tons | None | 6 · index 67% |
| Ducted, 3.5 to 4.5 tons | None | 7 · index 62% |
| Non-ducted, up to 1.5 tons | 27 · index 35% | 18 · index 66% |
| Non-ducted, 2 tons | 5 · index 29% | 4 · index 54% |
| Non-ducted, 2.5 to 3 tons | 5 · index 30% | 4 · index 70% |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 27% | 3 · index 59% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EXNOSCold-climate score, best model | ForestAirCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 59.0(50 is the typical model of its size class)FA-H09-D24TL-O-454with ducted air handler FA-D09-D24TL-I-4545 of 5 models qualify · AHRI 217549977 |
| Ducted, 2 tons | No models in this size class | 80.8(50 is the typical model of its size class)FA-H24-VKCE/OD-454with ducted air handler FA-H24-VKCE/AH-4543 of 3 models qualify · AHRI 217903145 |
| Ducted, 2.5 to 3 tons | No models in this size class | 70.1(50 is the typical model of its size class)FA-H36-VK/ODwith ducted air handler FA-H36-VK/AH6 of 6 models qualify · AHRI 217491807 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 76.9(50 is the typical model of its size class)FA-H48-VKCE/OD-454with ducted air handler FA-H48-VKCE/AH-4547 of 7 models qualify · AHRI 217903147 |
| Non-ducted, up to 1.5 tons | 70.1(50 is the typical model of its size class)T20230W20E12Also listed as T18230W2016 of 27 models qualify · AHRI 218083406 | 72.4(50 is the typical model of its size class) (higher)FA-MY18-D2TL-O-45418 of 18 models qualify · AHRI 218696897 |
| Non-ducted, 2 tons | None on this board (0 of 5 models qualify) | 60.1(50 is the typical model of its size class)FA-H24-D24TL-O-454with ductless indoor unit FA-K24-D24TL-I-4544 of 4 models qualify · AHRI 217549976 |
| Non-ducted, 2.5 to 3 tons | 48.6(50 is the typical model of its size class)T28230W20E112 of 5 models qualify · AHRI 218088488 | 68.7(50 is the typical model of its size class) (higher)FA-MY27-D3TL-O-4544 of 4 models qualify · AHRI 218696898 |
| Non-ducted, 3.5 to 4.5 tons | 24.7(50 is the typical model of its size class)T42230W20E111 of 1 models qualify · AHRI 218088490 | 42.9(50 is the typical model of its size class) (higher)FA-MY48-D5TL-O-454Also listed as FA-MY55-D5TL-O-4543 of 3 models qualify · AHRI 218696900 |
All-around best
| Size and duct type | EXNOSAll-around score, best model | ForestAirAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 73.3(50 is the typical model of its size class)FA-MY18-D2TL-O-4545 of 5 models have all five ratings · AHRI 218696902 |
| Ducted, 2 tons | No models in this size class | 79.2(50 is the typical model of its size class)FA-H24-VK/ODwith ducted air handler FA-H24-VK/AH3 of 3 models have all five ratings · AHRI 217491806 |
| Ducted, 2.5 to 3 tons | No models in this size class | 80.6(50 is the typical model of its size class)FA-MY27-D3TL-O-4546 of 6 models have all five ratings · AHRI 218696903 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 68.7(50 is the typical model of its size class)FA-H48-VK/ODwith ducted air handler FA-H48-VK/AH7 of 7 models have all five ratings · AHRI 217491808 |
| Non-ducted, up to 1.5 tons | 74.0(50 is the typical model of its size class)T20230W20E12Also listed as T18230W2027 of 27 models have all five ratings · AHRI 218083406 | 83.7(50 is the typical model of its size class) (higher)FA-MY18-D2TL-O-45418 of 18 models have all five ratings · AHRI 218696897 |
| Non-ducted, 2 tons | 41.6(50 is the typical model of its size class)A24230W20E12with ductless indoor unit A24230N20E12Also listed as A24230W208225 of 5 models have all five ratings · AHRI 218083395 | 58.9(50 is the typical model of its size class) (higher)FA-H24-D24TL-O-454with ductless indoor unit FA-K24-D24TL-I-4544 of 4 models have all five ratings · AHRI 217549976 |
| Non-ducted, 2.5 to 3 tons | 40.1(50 is the typical model of its size class)T28230W20E115 of 5 models have all five ratings · AHRI 218088488 | 83.4(50 is the typical model of its size class) (higher)FA-MY27-D3TL-O-4544 of 4 models have all five ratings · AHRI 218696898 |
| Non-ducted, 3.5 to 4.5 tons | 26.8(50 is the typical model of its size class)T42230W20E111 of 1 models have all five ratings · AHRI 218088490 | 67.4(50 is the typical model of its size class) (higher)FA-MY48-D5TL-O-454Also listed as FA-MY55-D5TL-O-4543 of 3 models have all five ratings · AHRI 218696900 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | EXNOS | ForestAir |
|---|---|---|
| COP at 5°F | beats 87% · 2.10A36230W20E12Also listed as A36230W20822Non-ducted, 2.5 to 3 tons | beats 85% · 2.20FA-H36-VK/ODDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 63% · 80%T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tons | beats 96% · 105%FA-MY18-D2TL-O-454Ducted, up to 1.5 tons |
| HSPF2 | beats 81% · 10.5T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tons | beats 96% · 10.5FA-M36-D4TL-O-454Ducted, 2.5 to 3 tons |
| SEER2 | beats 77% · 24.0T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tons | beats 100% · 22.0FA-MY27-D3TL-O-454Ducted, 2.5 to 3 tons |
| EER2 | beats 73% · 13.0T20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tons | beats 98% · 14.0FA-H24-VK/ODDucted, 2 tons |
| Heating capacity at 5°F | beats 89% · 16,000 Btu/hT20230W20E12Also listed as T18230W20Non-ducted, up to 1.5 tons | beats 98% · 19,800 Btu/hFA-MY18-D2TL-O-454Non-ducted, up to 1.5 tons |