ForestAir vs HAIER heat pumps
Measured against models of the same size and duct type, ForestAir scores higher on 3 of the 6 ratings. ForestAir has 37 outdoor models, HAIER has 38 outdoor models. ForestAir and HAIER have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ForestAir
- HAIER
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ForestAir | HAIER |
|---|---|---|
| Efficiency index | 64% (higher)median — | 51% (higher)median — |
| COP at 5°F | 44% (higher)median 2.00 | 32% (higher)median 1.80 |
| Capacity retention at 5°F | 62%median 75% | 62%median 80% |
| HSPF2 | 66%median 10.0 | 68%median 9.5 |
| SEER2 | 80% (higher)median 23.0 | 53% (higher)median 20.0 |
| EER2 | 61% (higher)median 12.5 | 42% (higher)median 12.0 |
| Heating capacity at 5°F | 58%median 18,500 Btu/h | 64%median 19,950 Btu/h |
| Outdoor models | 37 | 38 |
| AHRI certifications | 64 | 2,395 |
Share of models meeting each standard
| Standard | ForestAir | HAIER |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 97.3%36 models | 94.7%36 models |
| CEE 2026 Tier 1 (Split ASHP) | 97.3%36 models | 84.2%32 models |
| CEE Advanced Tier (Split ASHP) | 2.7%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 97.3%36 models | 81.6%31 models |
| DOE Cold Climate Heat Pump Challenge | 2.7%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 51.4%19 models | 71.1%27 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ForestAir
- HAIER
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ForestAir | HAIER |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 59% | 9 · index 52% |
| Ducted, 2 tons | 3 · index 70% | 6 · index 45% |
| Ducted, 2.5 to 3 tons | 6 · index 67% | 8 · index 52% |
| Ducted, 3.5 to 4.5 tons | 7 · index 62% | 7 · index 54% |
| Ducted, 5 tons and up | None | 1 · index 75% |
| Non-ducted, up to 1.5 tons | 18 · index 66% | 14 · index 49% |
| Non-ducted, 2 tons | 4 · index 54% | 5 · index 51% |
| Non-ducted, 2.5 to 3 tons | 4 · index 70% | 5 · index 45% |
| Non-ducted, 3.5 to 4.5 tons | 3 · index 59% | 2 · index 50% |
| Non-ducted, 5 tons and up | None | 1 · index 68% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ForestAirCold-climate score, best model | HAIERCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 59.0(50 is the typical model of its size class)FA-H09-D24TL-O-454with ducted air handler FA-D09-D24TL-I-4545 of 5 models qualify · AHRI 217549977 | 68.2(50 is the typical model of its size class) (higher)2Q20RT2BE**9 of 9 models qualify · AHRI 217021965 |
| Ducted, 2 tons | 80.8(50 is the typical model of its size class) (higher)FA-H24-VKCE/OD-454with ducted air handler FA-H24-VKCE/AH-4543 of 3 models qualify · AHRI 217903145 | 74.5(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler PE(S,T)35J5 of 6 models qualify · AHRI 218857291 |
| Ducted, 2.5 to 3 tons | 70.1(50 is the typical model of its size class)FA-H36-VK/ODwith ducted air handler FA-H36-VK/AH6 of 6 models qualify · AHRI 217491807 | 79.1(50 is the typical model of its size class) (higher)AU36VFPTYA6 of 8 models qualify · AHRI 218394141 |
| Ducted, 3.5 to 4.5 tons | 76.9(50 is the typical model of its size class)FA-H48-VKCE/OD-454with ducted air handler FA-H48-VKCE/AH-4547 of 7 models qualify · AHRI 217903147 | 80.4(50 is the typical model of its size class) (higher)AU48VFPTYA5 of 7 models qualify · AHRI 218394142 |
| Ducted, 5 tons and up | No models in this size class | 81.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394143 |
| Non-ducted, up to 1.5 tons | 72.4(50 is the typical model of its size class) (higher)FA-MY18-D2TL-O-45418 of 18 models qualify · AHRI 218696897 | 67.4(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models qualify · AHRI 218073018 |
| Non-ducted, 2 tons | 60.1(50 is the typical model of its size class)FA-H24-D24TL-O-454with ductless indoor unit FA-K24-D24TL-I-4544 of 4 models qualify · AHRI 217549976 | 62.9(50 is the typical model of its size class) (higher)3Q24RT2BE**4 of 5 models qualify · AHRI 217009757 |
| Non-ducted, 2.5 to 3 tons | 68.7(50 is the typical model of its size class)FA-MY27-D3TL-O-4544 of 4 models qualify · AHRI 218696898 | 74.4(50 is the typical model of its size class) (higher)AU36VFPTYA4 of 5 models qualify · AHRI 218394138 |
| Non-ducted, 3.5 to 4.5 tons | 42.9(50 is the typical model of its size class)FA-MY48-D5TL-O-454Also listed as FA-MY55-D5TL-O-4543 of 3 models qualify · AHRI 218696900 | 67.6(50 is the typical model of its size class) (higher)AU48VFPTYA2 of 2 models qualify · AHRI 218394139 |
| Non-ducted, 5 tons and up | No models in this size class | 64.2(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394140 |
All-around best
| Size and duct type | ForestAirAll-around score, best model | HAIERAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 73.3(50 is the typical model of its size class) (higher)FA-MY18-D2TL-O-4545 of 5 models have all five ratings · AHRI 218696902 | 66.5(50 is the typical model of its size class)1Q09RT2BE**with ducted air handler US09MB2BE9 of 9 models have all five ratings · AHRI 217036491 |
| Ducted, 2 tons | 79.2(50 is the typical model of its size class) (higher)FA-H24-VK/ODwith ducted air handler FA-H24-VK/AH3 of 3 models have all five ratings · AHRI 217491806 | 67.3(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM30E3TA56 of 6 models have all five ratings · AHRI 217270222 |
| Ducted, 2.5 to 3 tons | 80.6(50 is the typical model of its size class) (higher)FA-MY27-D3TL-O-4546 of 6 models have all five ratings · AHRI 218696903 | 75.0(50 is the typical model of its size class)AU36VFPTYA8 of 8 models have all five ratings · AHRI 218394141 |
| Ducted, 3.5 to 4.5 tons | 68.7(50 is the typical model of its size class)FA-H48-VK/ODwith ducted air handler FA-H48-VK/AH7 of 7 models have all five ratings · AHRI 217491808 | 70.2(50 is the typical model of its size class) (higher)AU48VFPTYA7 of 7 models have all five ratings · AHRI 218394142 |
| Ducted, 5 tons and up | No models in this size class | 74.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394143 |
| Non-ducted, up to 1.5 tons | 83.7(50 is the typical model of its size class) (higher)FA-MY18-D2TL-O-45418 of 18 models have all five ratings · AHRI 218696897 | 78.7(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models have all five ratings · AHRI 218073018 |
| Non-ducted, 2 tons | 58.9(50 is the typical model of its size class)FA-H24-D24TL-O-454with ductless indoor unit FA-K24-D24TL-I-4544 of 4 models have all five ratings · AHRI 217549976 | 68.8(50 is the typical model of its size class) (higher)3Q24RT2BE**5 of 5 models have all five ratings · AHRI 217009757 |
| Non-ducted, 2.5 to 3 tons | 83.4(50 is the typical model of its size class) (higher)FA-MY27-D3TL-O-4544 of 4 models have all five ratings · AHRI 218696898 | 76.7(50 is the typical model of its size class)AU36VFPTYA5 of 5 models have all five ratings · AHRI 218394138 |
| Non-ducted, 3.5 to 4.5 tons | 67.4(50 is the typical model of its size class)FA-MY48-D5TL-O-454Also listed as FA-MY55-D5TL-O-4543 of 3 models have all five ratings · AHRI 218696900 | 73.9(50 is the typical model of its size class) (higher)AU48VFPTYA2 of 2 models have all five ratings · AHRI 218394139 |
| Non-ducted, 5 tons and up | No models in this size class | 68.0(50 is the typical model of its size class)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394140 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ForestAir | HAIER |
|---|---|---|
| COP at 5°F | beats 85% · 2.20FA-H36-VK/ODDucted, 2.5 to 3 tons | beats 93% · 2.491U36T3PC*HEDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 96% · 105%FA-MY18-D2TL-O-454Ducted, up to 1.5 tons | beats 97% · 82%AU60VFPTYADucted, 5 tons and up |
| HSPF2 | beats 96% · 10.5FA-M36-D4TL-O-454Ducted, 2.5 to 3 tons | beats 100% · 13.5AU36VFPTYADucted, 2.5 to 3 tons |
| SEER2 | beats 100% · 22.0FA-MY27-D3TL-O-454Ducted, 2.5 to 3 tons | beats 95% · 27.01Q09RT2BE**Non-ducted, up to 1.5 tons |
| EER2 | beats 98% · 14.0FA-H24-VK/ODDucted, 2 tons | beats 99% · 14.4AU36VFPTYANon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 19,800 Btu/hFA-MY18-D2TL-O-454Non-ducted, up to 1.5 tons | beats 99% · 20,000 Btu/h2Q20RT2BE**Ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- ForestAir (median, middle 50%)
- HAIER (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| ForestAir, 47°F | 35 | 100% | 100% | 100% | 100% | 100% |
| ForestAir, 17°F | 35 | 72% | 73% | 76% | 83% | 99% |
| ForestAir, 5°F | 35 | 57% | 64% | 68% | 72% | 76% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| ForestAir, 47°F | 35 | 2.47 | 2.84 | 3.5 | 3.73 | 3.8 |
| ForestAir, 17°F | 35 | 2.01 | 2.1 | 2.2 | 2.28 | 2.4 |
| ForestAir, 5°F | 35 | 1.8 | 1.8 | 2 | 2.1 | 2.2 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HAIER, 47°F | 35 | 100% | 100% | 100% | 100% | 100% |
| HAIER, 17°F | 35 | 59% | 60% | 64% | 76% | 80% |
| HAIER, 5°F | 35 | 63% | 70% | 73% | 81% | 91% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HAIER, 47°F | 35 | 3.08 | 3.2 | 3.5 | 3.65 | 3.76 |
| HAIER, 17°F | 35 | 2.21 | 2.4 | 2.5 | 2.6 | 2.8 |
| HAIER, 5°F | 35 | 1.8 | 1.8 | 1.8 | 1.83 | 2.06 |
Source: NEEP ccASHP list · as of