Measured against models of the same size and duct type, VKIN scores higher on 6 of the 6 ratings. LUORISE has 31 outdoor models, VKIN has 32 outdoor models. LUORISE and VKIN have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
LUORISE and VKIN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, VKIN scores higher on 6 of the 6 ratings.
  • LUORISE
  • VKIN
  • Other ranked manufacturers
LUORISEVKIN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingLUORISEVKIN
Efficiency index32%median —59%median —
COP at 5°F30%median 1.9052%median 2.00
Capacity retention at 5°F34%median 71%57%median 76%
HSPF246%median 9.562%median 9.8
SEER234%median 20.072%median 22.5
EER221%median 9.550%median 12.0
Heating capacity at 5°F39%median 12,000 Btu/h57%median 18,250 Btu/h
Outdoor models3132
AHRI certifications3146

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardLUORISEVKIN
CEE 2025 Tier 1 (Split ASHP)48.4%15 models93.8%30 models
CEE 2026 Tier 1 (Split ASHP)48.4%15 models93.8%30 models
CEE Advanced Tier (Split ASHP)0%0 models3.1%1 models
Xcel Energy Colorado cold-climate ASHP (2025)51.6%16 models90.6%29 models
DOE Cold Climate Heat Pump Challenge0%0 models3.1%1 models
ENERGY STAR Cold Climate0%0 models71.9%23 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • LUORISE
  • VKIN
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeLUORISEVKIN
Ducted, 2 tons1 · index 37%2 · index 76%
Ducted, 2.5 to 3 tons1 · index 51%4 · index 63%
Ducted, 3.5 to 4.5 tons2 · index 41%6 · index 60%
Ducted, up to 1.5 tonsNone1 · index 53%
Non-ducted, up to 1.5 tons16 · index 34%15 · index 62%
Non-ducted, 2 tons6 · index 25%4 · index 51%
Non-ducted, 2.5 to 3 tons4 · index 27%2 · index 59%
Non-ducted, 3.5 to 4.5 tons1 · index 27%3 · index 40%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeLUORISECold-climate score, best modelVKINCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class49.0(50 is the typical model of its size class)URHT-18FM2N41 of 1 models qualify · AHRI 218258554
Ducted, 2 tons42.0(50 is the typical model of its size class)L03-24K2V-18S-Owith ducted air handler L03-24K2V-18S-I1 of 1 models qualify · AHRI 21807924280.8(50 is the typical model of its size class) (higher)UCHA-24HDCSN4with ducted air handler UCHA-24HDCN42 of 2 models qualify · AHRI 218385960
Ducted, 2.5 to 3 tons55.0(50 is the typical model of its size class)L03-36K2V-19S-Owith ducted air handler L03-36K2V-19S-I1 of 1 models qualify · AHRI 21807924370.1(50 is the typical model of its size class) (higher)UCHA-36HDCTwith ducted air handler UCHA-36HDC4 of 4 models qualify · AHRI 218385958
Ducted, 3.5 to 4.5 tons43.2(50 is the typical model of its size class)L03-48K2V-18S-Owith ducted air handler L03-48K2V-18S-I2 of 2 models qualify · AHRI 21807924476.9(50 is the typical model of its size class) (higher)UCHA-48HDCSN4with ducted air handler UCHA-48HDCN46 of 6 models qualify · AHRI 218385962
Non-ducted, up to 1.5 tons60.8(50 is the typical model of its size class)L01-CS-09K2V-20S-Owith ductless indoor unit L01-CS-09K2V-20S-WC-I8 of 16 models qualify · AHRI 21846836483.4(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)13 of 15 models qualify · AHRI 216498652
Non-ducted, 2 tons39.5(50 is the typical model of its size class)L01-CS-24K2V-20S-Owith ductless indoor unit L01-CS-24K2V-20S-WC-I3 of 6 models qualify · AHRI 21846836759.1(50 is the typical model of its size class) (higher)URHT-24WDCN4-SE25(O)with ductless indoor unit URHT-24WDCN4-SE25(I)4 of 4 models qualify · AHRI 218858157
Non-ducted, 2.5 to 3 tons48.6(50 is the typical model of its size class)L01-3Z-27K2V-20S-O2 of 4 models qualify · AHRI 21804643758.2(50 is the typical model of its size class) (higher)URHT-27FM3N42 of 2 models qualify · AHRI 218258550
Non-ducted, 3.5 to 4.5 tons24.7(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models qualify · AHRI 21804643931.5(50 is the typical model of its size class) (higher)URHT-42FM5N43 of 3 models qualify · AHRI 218258552

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeLUORISEAll-around score, best modelVKINAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class53.1(50 is the typical model of its size class)URHT-18FM2N41 of 1 models have all five ratings · AHRI 218258554
Ducted, 2 tons37.0(50 is the typical model of its size class)L03-24K2V-18S-Owith ducted air handler L03-24K2V-18S-I1 of 1 models have all five ratings · AHRI 21807924279.2(50 is the typical model of its size class) (higher)UCHA-24HDCTwith ducted air handler UCHA-24HDC2 of 2 models have all five ratings · AHRI 218385956
Ducted, 2.5 to 3 tons51.4(50 is the typical model of its size class)L03-36K2V-19S-Owith ducted air handler L03-36K2V-19S-I1 of 1 models have all five ratings · AHRI 21807924366.2(50 is the typical model of its size class) (higher)UCHA-36HDCTwith ducted air handler UCHA-36HDC4 of 4 models have all five ratings · AHRI 218385958
Ducted, 3.5 to 4.5 tons43.4(50 is the typical model of its size class)L03-48K2V-18S-Owith ducted air handler L03-48K2V-18S-I2 of 2 models have all five ratings · AHRI 21807924468.7(50 is the typical model of its size class) (higher)UCHA-48HDCTwith ducted air handler UCHA-48HDC6 of 6 models have all five ratings · AHRI 218385957
Non-ducted, up to 1.5 tons63.6(50 is the typical model of its size class)L01-CS-09K2V-20S-Owith ductless indoor unit L01-CS-09K2V-20S-WC-I16 of 16 models have all five ratings · AHRI 21846836485.1(50 is the typical model of its size class) (higher)URHA-09WDCN4(O)with ductless indoor unit URHA-09WDCN4(I)15 of 15 models have all five ratings · AHRI 216498652
Non-ducted, 2 tons38.0(50 is the typical model of its size class)L01-FC-24K2V-20S-Owith ductless indoor unit L01-FC-24K2V-20S-WC-I6 of 6 models have all five ratings · AHRI 21846837360.3(50 is the typical model of its size class) (higher)URHA-24WDCN4(O)with ductless indoor unit URHA-24WDCN4(I)4 of 4 models have all five ratings · AHRI 216498655
Non-ducted, 2.5 to 3 tons40.1(50 is the typical model of its size class)L01-3Z-27K2V-20S-O4 of 4 models have all five ratings · AHRI 21804643765.9(50 is the typical model of its size class) (higher)URHT-27FM3N42 of 2 models have all five ratings · AHRI 218258550
Non-ducted, 3.5 to 4.5 tons26.8(50 is the typical model of its size class)L01-5Z-42K2V-20S-O1 of 1 models have all five ratings · AHRI 21804643942.3(50 is the typical model of its size class) (higher)URHT-42FM5N43 of 3 models have all five ratings · AHRI 218258552

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingLUORISEVKIN
COP at 5°Fbeats 64% · 2.00L01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tonsbeats 98% · 2.49URHA-18WDCNX-ONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 71% · 86%L01-DU-09K2V-20S-ONon-ducted, up to 1.5 tonsbeats 92% · 100%UCHA-24HDCSN4Ducted, 2 tons
HSPF2beats 66% · 10.0L01-18K2V-20S-P-ONon-ducted, up to 1.5 tonsbeats 96% · 10.5URHT-36FM4N4Ducted, 2.5 to 3 tons
SEER2beats 82% · 19.0L03-36K2V-19S-ODucted, 2.5 to 3 tonsbeats 98% · 21.0URHT-27FM3N4Ducted, 2.5 to 3 tons
EER2beats 59% · 12.5L01-09K2V-20S-P-ONon-ducted, up to 1.5 tonsbeats 98% · 14.0UCHA-24HDCTDucted, 2 tons
Heating capacity at 5°Fbeats 84% · 14,000 Btu/hL01-2Z-18K2V-20S-ONon-ducted, up to 1.5 tonsbeats 94% · 18,000 Btu/hURHA-18WDCN4(O)Non-ducted, up to 1.5 tons