Skip to content

PERFECTAIRE vs PREMIUM LEVELLA heat pumps

Measured against models of the same size and duct type, PERFECTAIRE scores higher on 5 of the 6 ratings. PERFECTAIRE has 22 outdoor models, PREMIUM LEVELLA has 17 outdoor models. PERFECTAIRE and PREMIUM LEVELLA have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
PERFECTAIRE and PREMIUM LEVELLA on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, PERFECTAIRE scores higher on 5 of the 6 ratings.
  • PERFECTAIRE
  • PREMIUM LEVELLA
  • Other ranked manufacturers
PERFECTA…PREMIUM …

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingPERFECTAIREPREMIUM LEVELLA
Efficiency index63% (higher)median —48% (higher)median —
COP at 5°F55%median 2.0056%median 2.00
Capacity retention at 5°F72% (higher)median 94%37% (higher)median 70%
HSPF271% (higher)median 10.149% (higher)median 10.0
SEER258% (higher)median 20.050% (higher)median 21.0
EER262% (higher)median 12.044% (higher)median 12.0
Heating capacity at 5°F70% (higher)median 18,000 Btu/h40% (higher)median 11,600 Btu/h
Outdoor models2217
AHRI certifications4217

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardPERFECTAIREPREMIUM LEVELLA
CEE 2025 Tier 1 (Split ASHP)81.8%18 models70.6%12 models
CEE 2026 Tier 1 (Split ASHP)77.3%17 models70.6%12 models
CEE Advanced Tier (Split ASHP)4.5%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)81.8%18 models47.1%8 models
DOE Cold Climate Heat Pump Challenge4.5%1 models0%0 models
ENERGY STAR Cold Climate81.8%18 models41.2%7 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • PERFECTAIRE
  • PREMIUM LEVELLA
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,327 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00599 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typePERFECTAIREPREMIUM LEVELLA
Ducted, up to 1.5 tons2 · index 78%None
Ducted, 2.5 to 3 tons4 · index 81%None
Ducted, 3.5 to 4.5 tons4 · index 83%None
Non-ducted, up to 1.5 tons12 · index 54%10 · index 43%
Non-ducted, 2 tons2 · index 48%3 · index 46%
Non-ducted, 2.5 to 3 tons4 · index 56%3 · index 65%
Non-ducted, 3.5 to 4.5 tons4 · index 60%1 · index 72%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typePERFECTAIRECold-climate score, best modelPREMIUM LEVELLACold-climate score, best model
Ducted, up to 1.5 tons71.1(50 is the typical model of its size class)4PAMS18-HH-MZO2Also listed as 4PAMS18-HH-MZO32 of 2 models qualify · AHRI 217221808No models in this size class
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class)4PAMS36-HH-MZO4Also listed as 4PAMS36-HH-MZO54 of 4 models qualify · AHRI 217221814No models in this size class
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)4PAMS48-HH-MZO5Also listed as 4PAMS48-HH-MZO64 of 4 models qualify · AHRI 217221817No models in this size class
Non-ducted, up to 1.5 tons94.5(50 is the typical model of its size class) (higher)4PAMSHH06-SZOwith ductless indoor unit 4PAMSHH06-UVW8 of 12 models qualify · AHRI 21722180280.7(50 is the typical model of its size class)PIAW1825080ABwith ductless indoor unit PIAW1825079AA4 of 10 models qualify · AHRI 216775680
Non-ducted, 2 tons77.6(50 is the typical model of its size class) (higher)4PAMSHH24-SZOwith ductless indoor unit 4PAMSHH24-UVW2 of 2 models qualify · AHRI 21722180668.5(50 is the typical model of its size class)PIAWMZ2482380AB1 of 3 models qualify · AHRI 217014451
Non-ducted, 2.5 to 3 tons72.8(50 is the typical model of its size class) (higher)4PAMS36-HH-MZO4Also listed as 4PAMS36-HH-MZO54 of 4 models qualify · AHRI 21722181558.3(50 is the typical model of its size class)PIAWMZ3082380AB2 of 3 models qualify · AHRI 217014452
Non-ducted, 3.5 to 4.5 tons70.4(50 is the typical model of its size class) (higher)4PAMS55-HH-MZO5Also listed as 4PAMS55-HH-MZO64 of 4 models qualify · AHRI 21722182151.0(50 is the typical model of its size class)PIAWMZ4282480AB1 of 1 models qualify · AHRI 217014454

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typePERFECTAIREAll-around score, best modelPREMIUM LEVELLAAll-around score, best model
Ducted, up to 1.5 tons77.8(50 is the typical model of its size class)4PAMS18-HH-MZO2Also listed as 4PAMS18-HH-MZO32 of 2 models have all five ratings · AHRI 217221808No models in this size class
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)4PAMS36-HH-MZO4Also listed as 4PAMS36-HH-MZO54 of 4 models have all five ratings · AHRI 217221814No models in this size class
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class)4PAMS48-HH-MZO5Also listed as 4PAMS48-HH-MZO64 of 4 models have all five ratings · AHRI 217221817No models in this size class
Non-ducted, up to 1.5 tons94.5(50 is the typical model of its size class) (higher)4PAMSHH06-SZOwith ductless indoor unit 4PAMSHH06-UVW12 of 12 models have all five ratings · AHRI 21722180284.3(50 is the typical model of its size class)PIAW1825080ABwith ductless indoor unit PIAW1825079AA10 of 10 models have all five ratings · AHRI 216775680
Non-ducted, 2 tons74.3(50 is the typical model of its size class) (higher)4PAMSHH24-SZOwith ductless indoor unit 4PAMSHH24-UVW2 of 2 models have all five ratings · AHRI 21722180673.3(50 is the typical model of its size class)PIAWMZ2482380AB3 of 3 models have all five ratings · AHRI 217014451
Non-ducted, 2.5 to 3 tons67.0(50 is the typical model of its size class)4PAMS36-HH-MZO4Also listed as 4PAMS36-HH-MZO54 of 4 models have all five ratings · AHRI 21722181367.4(50 is the typical model of its size class) (higher)PIAWMZ3082380AB2 of 3 models have all five ratings · AHRI 217014452
Non-ducted, 3.5 to 4.5 tons62.6(50 is the typical model of its size class)4PAMS55-HH-MZO5Also listed as 4PAMS55-HH-MZO64 of 4 models have all five ratings · AHRI 21722181972.3(50 is the typical model of its size class) (higher)PIAWMZ4282480AB1 of 1 models have all five ratings · AHRI 217014454

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingPERFECTAIREPREMIUM LEVELLA
COP at 5°Fbeats 92% · 2.294PAMSHH06-SZONon-ducted, up to 1.5 tonsbeats 95% · 2.21PIAW3417080ABNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 95% · 104%4PAMS36-HH-MZO4Also listed as 4PAMS36-HH-MZO5Non-ducted, 2.5 to 3 tonsbeats 81% · 90%PIAWMZ2482380ABNon-ducted, 2 tons
HSPF2beats 99% · 11.04PAMS48-HH-MZO5Also listed as 4PAMS48-HH-MZO6Ducted, 3.5 to 4.5 tonsbeats 81% · 10.5PIAW1825080ABNon-ducted, up to 1.5 tons
SEER2beats 96% · 20.44PAMS48-HH-MZO5Also listed as 4PAMS48-HH-MZO6Ducted, 3.5 to 4.5 tonsbeats 94% · 24.0PIAWMZ4282480ABNon-ducted, 3.5 to 4.5 tons
EER2beats 96% · 16.04PAMSHH06-SZONon-ducted, up to 1.5 tonsbeats 87% · 12.5PIAWMZ4282480ABNon-ducted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 95% · 37,400 Btu/h4PAMS36-HH-MZO4Also listed as 4PAMS36-HH-MZO5Non-ducted, 2.5 to 3 tonsbeats 87% · 15,000 Btu/hPIAW1825080ABNon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter