Skip to content

Ranked by SEER2 only: 5 tons and up, by duct type

Seasonal cooling efficiency (2023 DOE test procedure). This board ranks by that one rating; it is not the overall cold-climate verdict, which is the cold-climate board. Inside one size and duct type the raw ratings are comparable, so these boards rank by the rating itself, more than one model per manufacturer when they earn it. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

New to heat pump ratings? The Simple view explains them in plain words →

LeaderboardsData as of updated · sources

Ducted, 5 tons and up: ranked by SEER2 only

Ducted, 5 tons and up: ranked by SEER2. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeSEER2COP@5°FCap. 5/47HSPF2EER2Btu/h @5°FMeetsCombosAHRI ref.
127VNA060A*030*CARRIER · Infinity 20 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 290VAN060**AA, Airquest B5H0V60*K*AAACarrier5 tons57,500 Btu/h · Ducted20.02.1270%9.010.040,500CEE 25CEE 26XcelES CC222215662628
2H5H0V60*K*AAA*HEIL · QUIETCOMFORT DELUXE 20 VS HPwith ducted air handler FCMA5B60L0D*+WALLCONAlso sold as Comfortmaker C5H0V60*K*AAA, Kenmore (C,H,T)5H0V60*K*AAA, Tempstar T5H0V60*K*AAACarrier5 tons57,500 Btu/h · Ducted20.02.1269%9.010.040,500CEE 25CEE 26CEE AdvDOEES CC575215662885
327VNA360A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAACarrier5 tons58,000 Btu/h · Ducted20.02.1874%9.012.544,500CEE 25CEE 26XcelES CC191215931484
4H5H3V60*K*AAA*HEIL · QUIETCOMFORT DELUXE 23 VS HPwith ducted air handler FCMA5B60L0D*+WALLCONAlso sold as Comfortmaker C5H3V60*K*AAA, Kenmore (C,H,T)5H3V60*K*AAA, Tempstar T5H3V60*K*AAACarrier5 tons58,000 Btu/h · Ducted20.02.0674%8.512.544,500CEE 25CEE 26XcelES CC543215931488
5AUWR-60U3TH5HISENSE · Hi-PRO HDwith ducted air handler AUH-60UX3TEH3Hisense5 tons57,000 Btu/h · Ducted19.02.4275%9.011.042,500CEE 25CEE 26XcelES CC11214802098
6AUWR-6024PHISENSE · Hi-PRO HDwith ducted air handler AUH-6024Also listed as AOH-60U3T24PHisense5 tons57,000 Btu/h · Ducted19.02.4674%9.011.042,000CEE 25CEE 26XcelES CC17214855379
7MRD-60HWD1N10-M18GMIDEA · MRDV-18HAlso listed as MRD-60HWD1N10-M18GBMidea5 tons57,000 Btu/h · Ducted19.01.8570%9.011.240,000CEE 25CEE 26XcelES CC1215894250
8BPBA-60RCB-M18SBOSCH · IDP Premium LGWPAlso listed as BPBB-60RTB-M18SBosch5 tons57,000 Btu/h · Ducted19.01.8570%9.011.240,000CEE 25CEE 26XcelES CC1216011943
9AM060FCMDCG1SAMSUNG · DVM S MiniSamsung5 tons60,000 Btu/h · Ducted19.02.0485%10.511.756,250CEE 25CEE 26XcelES CC3216016316
10VPD060H6M-5PLENNOX · DVM S MiniLennox5 tons60,000 Btu/h · Ducted19.02.0485%10.511.756,250CEE 25CEE 26XcelES CC3216054512

Ducted, 5 tons and up board

Non-ducted, 5 tons and up: ranked by SEER2 only

Non-ducted, 5 tons and up: ranked by SEER2. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeSEER2COP@5°FCap. 5/47HSPF2EER2Btu/h @5°FMeetsCombosAHRI ref.
1MCY-MUB0608HS2P-ULTOSHIBA CARRIER · MCY-MUB0608HS2P-ULCarrier5 tons60,000 Btu/h · Non-ducted23.32.0260%10.412.238,500CEE 25CEE 264216760289
2ZRUM060GSS0LG · ZRUM060GSS0LG5 tons60,000 Btu/h · Non-ducted23.02.1081%10.013.054,000CEE 25CEE 26XcelES CC3214914943
3AM060FCMDCG1SAMSUNG · DVM S MiniSamsung5 tons60,000 Btu/h · Non-ducted23.02.1185%11.013.856,250CEE 25CEE 26XcelES CC3216032696
4VPD060H6M-5PLENNOX · DVM S MiniLennox5 tons60,000 Btu/h · Non-ducted23.02.1185%11.013.856,250CEE 25CEE 26XcelES CC3216054508
5GMV-V60WL/NHC-T(U)GREE · Ultra Heat GMV6 MiniAlso sold as Tosot TMV-V60WL/NHC-T(U)Gree5 tons60,000 Btu/h · Non-ducted22.52.2072%9.210.546,500CEE 25CEE 26XcelES CC3216772249
6AOUK060MSAN7FUJITSU · J-7Fujitsu5 tons60,000 Btu/h · Non-ducted22.22.3570%9.511.046,500CEE 25CEE 26XcelES CC3218466063
7D5CMRAH55FAKMIDEAAlso sold as MDV M6OE30-60HFN10-M1D, MDV M6OE30-60HFN10-M1, Bryant 37MGRAQ55FA3, Arcoaire D5CMRAH55FAK; also listed as 37MGRAQ55FA3Midea5 tons60,000 Btu/h · Non-ducted22.02.2065%9.610.039,000CEE 25CEE 263215357450
8MO6EX-H60B-2AMIDEAAlso sold as MDV M6OE30-60HFN10-M1D-D; also listed as M6OE30-60HFN10-M1PMidea5 tons60,000 Btu/h · Non-ducted22.02.2065%9.510.039,000CEE 25CEE 263215471454
9MOM60H2BM6AINNOVAIRAlso listed as MOM60H2BM6BInnovair5 tons60,000 Btu/h · Non-ducted22.02.2065%9.510.039,000CEE 25CEE 263215835696
10BMMZ60CBLUERIDGEAlso listed as BXM1A60SC0BlueRidge5 tons60,000 Btu/h · Non-ducted22.02.2065%9.510.039,000CEE 25CEE 263215853994

Non-ducted, 5 tons and up board

Download CSV of these SEER2 boardsEvery board above in one file, ranked by value within each peer group.

Typical SEER2 by size and duct type

The median model of each peer group. The spread between groups is why models are only compared within their own.
SEER2 by size and duct typeEvery model, one row per peer group; the highlighted row is the one on this board · Low-GWP (R-454B, R-32)
  • All models of the group (shape)
  • Median and middle 50% / 80%
  • Leaderboard models
Ducted, 5 tons and up15.8458 modelsNon-ducted, 5 tons and up20.085 modelsmedian

Source: AHRI Directory · as of

Median SEER2 of the representative certification, per peer group
Peer groupModelsMedian SEER2
Ducted, up to 1.5 tons1,82716.0
Ducted, 2 tons1,15218.0
Ducted, 2.5–3 tons2,19816.5
Ducted, 3.5–4.5 tons2,60715.9
Ducted, 5 tons and up45815.8
Non-ducted, up to 1.5 tons3,56821.4
Non-ducted, 2 tons90321.0
Non-ducted, 2.5–3 tons1,14021.0
Non-ducted, 3.5–4.5 tons57021.1
Non-ducted, 5 tons and up8520.0