Skip to content

Top cold-climate picks: 5 tons and up, by duct type

Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F. COP at 5°F alone is not used: it is measured at whatever heat output the unit delivers at 5°F, so a unit with little output there can still post a high COP. The single-rating boards remain, each labelled as ranked by that one rating. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

New to heat pump ratings? The Simple view explains them in plain words →

LeaderboardsData as of updated · sources

Top cold-climate picks: Ducted, 5 tons and up

79 of 479 models in this size class qualify. 262 keep less than 70% of their heat at 5°F and 138 have no 5°F heat output rating, so they cannot show it. 64 of the qualifiers are from manufacturers with a QMID on file (the ranked pool).

Ducted, 5 tons and up: qualifiers ranked by cold-climate score (mean of the three peer percentiles); equal scores go to the higher heat output at 5°F. Every number in a row is from the pairing the score is computed on: in each duct type, the model’s best-scoring pairing that keeps at least 70% of its heat.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2EER2MeetsCombosAHRI ref.ScoreBeats on Cap. 5/47Beats on COP@5°FBeats on HSPF2
1MCY-MUB0608HS2P-ULTOSHIBA CARRIER · MCY-MUB0608HS2P-ULCarrier5 tons60,000 Btu/h · Ducted73%2.2210.147,00018.910.1CEE 25CEE 26Xcel421676324994.791%95%99%
2KUMXB601ALG · KUMXB601ALG5 tons60,000 Btu/h · Ducted82%2.339.552,50018.511.7CEE 25CEE 26Xcel321540234494.697%97%90%
3AUWR-60U3TH5HISENSE · Hi-PRO HDwith ducted air handler AUH-60UX3TEH3Hisense5 tons57,000 Btu/h · Ducted75%2.429.042,50019.011.0CEE 25CEE 26XcelES CC1121480209888.694%98%74%
4AUWR-6024PHISENSE · Hi-PRO HDwith ducted air handler AUH-6024Also listed as AOH-60U3T24PHisense5 tons57,000 Btu/h · Ducted74%2.469.042,00019.011.0CEE 25CEE 26XcelES CC1721485537988.391%100%74%
5AVW-60F3DAH2HisenseHisense5 tons60,000 Btu/h · Ducted100%2.1010.163,00017.010.5CEE 25CEE 26CEE AdvXcelDOE321661825388.2100%66%99%
6CHV6-RS60URBMHHCooper & HunterCooper&Hunter5 tons60,000 Btu/h · Ducted100%2.1010.163,00017.010.5CEE 25CEE 26CEE AdvXcelDOE321702655888.2100%66%99%
7AM060FCMDCG1SAMSUNG · DVM S MiniSamsung5 tons60,000 Btu/h · Ducted85%2.0410.556,25019.011.7CEE 25CEE 26XcelES CC321601631683.798%54%99%
8VPD060H6M-5PLENNOX · DVM S MiniLennox5 tons60,000 Btu/h · Ducted85%2.0410.556,25019.011.7CEE 25CEE 26XcelES CC321605451283.798%54%99%
927VNA360A*030*CARRIER · Infinity 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 293VAN060**AA, HEIL B5H3V60*K*AAACarrier5 tons58,000 Btu/h · Ducted74%2.189.044,50020.012.5CEE 25CEE 26XcelES CC19121593148482.392%81%74%
103TXK2260AF00HAATrane · TraneAlso listed as 3TVHS060SF000AATrane5 tons60,000 Btu/h · Ducted82%2.0011.053,00016.811.5CEE 25CEE 26Xcel221845102581.196%47%100%

Ducted, 5 tons and up board

Top cold-climate picks: Non-ducted, 5 tons and up

32 of 86 models in this size class qualify. 54 keep less than 70% of their heat at 5°F. 30 of the qualifiers are from manufacturers with a QMID on file (the ranked pool).

Non-ducted, 5 tons and up: qualifiers ranked by cold-climate score (mean of the three peer percentiles); equal scores go to the higher heat output at 5°F. Every number in a row is from the pairing the score is computed on: in each duct type, the model’s best-scoring pairing that keeps at least 70% of its heat.
# · Outdoor modelManufacturerSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2EER2MeetsCombosAHRI ref.ScoreBeats on Cap. 5/47Beats on COP@5°FBeats on HSPF2
1AVW-60F3DAH2HisenseHisense5 tons60,000 Btu/h · Non-ducted100%2.3011.063,00021.511.0CEE 25CEE 26CEE AdvXcelDOE321661825498.299%97%98%
2CHV6-RS60URBMHHCooper & HunterCooper&Hunter5 tons60,000 Btu/h · Non-ducted100%2.3011.063,00021.511.0CEE 25CEE 26CEE AdvXcelDOE321702655998.299%97%98%
3KUMXB601ALG · KUMXB601ALG5 tons58,000 Btu/h · Non-ducted82%2.339.852,50019.511.9CEE 25CEE 26Xcel321540863384.788%98%68%
4AM060FCMDCG1SAMSUNG · DVM S MiniSamsung5 tons60,000 Btu/h · Non-ducted85%2.1111.056,25023.013.8CEE 25CEE 26XcelES CC321603269684.194%61%98%
5VPD060H6M-5PLENNOX · DVM S MiniLennox5 tons60,000 Btu/h · Non-ducted85%2.1111.056,25023.013.8CEE 25CEE 26XcelES CC321605450884.194%61%98%
6ZRUM060GSS0LG · ZRUM060GSS0LG5 tons60,000 Btu/h · Non-ducted81%2.1010.054,00023.013.0CEE 25CEE 26XcelES CC321491494372.688%58%71%
7AOUK060MSAN7FUJITSU · J-7Fujitsu5 tons60,000 Btu/h · Non-ducted70%2.359.546,50022.211.0CEE 25CEE 26XcelES CC321846606370.666%99%47%
8RXTA60AAVJU*DAIKINDaikin5 tons57,500 Btu/h · Non-ducted70%2.359.538,50020.58.7None321717841170.264%99%47%
9MXZ-SM60NLHZ-**Mitsubishi Electric · Smart MultiAlso listed as PUMY-HL60NKMUMitsubishi Electric5 tons60,000 Btu/h · Non-ducted96%2.0010.962,00020.012.0CEE 25CEE 26XcelES CC421764300370.097%19%94%
10MXZ-SM60NLHZ***Mitsubishi Electric · Smart MultiMitsubishi Electric5 tons60,000 Btu/h · Non-ducted94%2.0010.962,00020.012.0CEE 25CEE 26XcelES CC421764300069.495%19%94%

Non-ducted, 5 tons and up board

Download CSV of these cold-climate boardsEvery board above in one file, ranked by cold-climate score within each peer group.