Skip to content

CEE 2026 Tier 1 (Split ASHP): 6,854 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
6,854
Qualifying certifications
202,824
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,222 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,351
2.00 to under 2.102,428
2.10 to under 2.201,325
2.20 to under 2.30777
2.30 to under 2.40512
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,157 rated models · median 72%87% of rated models reach 50% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,156
80 to under 85%799
85 to under 90%375
90 to under 95%720
95 to under 100%582
100 to under 105%758
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF212,307 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,112
7.8 to under 8.0381
8.0 to under 8.3724
8.3 to under 8.5177
8.5 to under 8.81,450
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,372
9.8 to under 10.0306
10.0 to under 10.31,627
10.3 to under 10.5228
10.5 to under 10.8603
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,331 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,004
14.5 to under 15.0192
15.0 to under 15.51,100
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5681
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.019
27.0 to under 27.561
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER212,327 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.594
8.5 to under 9.0214
9.0 to under 9.5703
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,679
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5275
14.5 to under 15.0114
15.0 to under 15.5180
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.9% · 2,870 of 4,716
2 tons66.2% · 1,157 of 1,748
2.5–3 tons54.6% · 1,489 of 2,726
3.5–4.5 tons44.4% · 1,193 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.6%1,974 / 6,057
Non-ducted67.7%2,768 / 4,089
Ducted and non-ducted96.5%2,112 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree572 of 71779.8%
Midea403 of 54673.8%
Carrier288 of 81635.3%
BlueRidge141 of 19273.4%
Lennox139 of 33741.2%
Daikin137 of 39434.8%
TCL134 of 17775.7%
Trane133 of 36336.6%
Mitsubishi Electric126 of 15680.8%
Hisense122 of 16175.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 101 of 275
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
2501MWHQ048NC2AA*GE Appliances · MRV 7SGE Appliances4 tons48,000 Btu/h · Ducted and non-ducted2.0098%10.621.6CEE 25CEE 26XcelES CC2218309297
2502MWHQ060NC2AA*GE Appliances · MRV 7SGE Appliances5 tons60,000 Btu/h · Ducted and non-ducted2.0078%10.521.0CEE 25CEE 26XcelES CC2218325037
2503NS15H18HA5***GE Applianceswith ducted air handler D(A,C,E)30B3J+TDRGE Appliances1.5 tons17,000 Btu/h · Ducted2.64102%7.814.3CEE 25CEE 26XcelES CC134218358333
2504NS15H30HA5***GE Applianceswith ducted air handler D(A,C,E)36A4J+TDRGE Appliances2.5 tons27,200 Btu/h · Ducted2.8969%8.514.3CEE 25CEE 26Xcel304218358339
2505NS16H24SA5-**AGEwith indoor coil D(A,C,E)24B4J+TDR and furnace NF80D090S4BGE Appliances2 tons21,600 Btu/h · Ducted2.6963%8.115.2CEE 25CEE 26521217187806
2506NS18H24HA5***GE Applianceswith ducted air handler C(A,C,D,E)24A3J+TDRGE Appliances2 tons22,400 Btu/h · Ducted3.1382%8.515.9CEE 25CEE 26CEE AdvXcelDOEES CC1,278217596950
2507NS18H36HA5***GE Applianceswith indoor coil D(A,C,E)36D4J+TDR and furnace NF97D070V4BGE Appliances3 tons33,000 Btu/h · Ducted2.6281%8.517.0CEE 25CEE 26CEE AdvXcelDOEES CC1,375217179621
2508NS18H60HA5***GE Applianceswith ducted air handler L(E,G)M48EJGE Appliances4 tons45,000 Btu/h · Ducted2.6380%9.518.0CEE 25CEE 26CEE AdvXcelDOEES CC1,643217505636
2509NS19H36MA5-**AGE · NS19H Serieswith ducted air handler NAM36V2TA5*-GE Appliances3 tons35,200 Btu/h · Ducted2.2052%8.418.0CEE 25CEE 26Xcel265217732951
2510NS19H60MA5-**AGE · NS19H Serieswith ducted air handler NAM60V2TA5*-GE Appliances4 tons48,000 Btu/h · Ducted2.2669%9.018.0CEE 25CEE 26157217733031
2511NS21H24MA5-**AGEwith indoor coil D(A,C,E)24C3Z+TXV+TDR and furnace NF96U070S3BGE Appliances2 tons21,400 Btu/h · Ducted2.73109%9.519.0CEE 25CEE 26CEE AdvXcelDOEES CC96218792657
2512NS21H36MA5-**AGEwith indoor coil D(A,C,E)36C3Z+TXV+TDR and furnace NF80U045S3AGE Appliances2.5 tons31,400 Btu/h · Ducted4.0093%10.019.0CEE 25CEE 26XcelES CC143218792658
2513NS21H48MA5-**AGEwith indoor coil D(A,C,E)48D4Z+TXV+TDR and furnace NF80U110S5CGE Appliances3.5 tons44,500 Btu/h · Ducted2.57100%9.020.0CEE 25CEE 26CEE AdvXcelDOEES CC83218792661
2514NS21H60MA5-**AGEwith indoor coil D(A,C,E)60A4Z+TXV+TDR and furnace NF80U135S5DGE Appliances4 tons49,500 Btu/h · Ducted2.7983%8.119.0CEE 25CEE 26XcelES CC64218806229
2515AVVL12DMXWAK1GE APPLIANCES ZONELINEGE APPLIANCES ZONELINE1 ton12,500 Btu/h · Ducted1.8582%8.117.0CEE 25CEE 26Xcel1216797479
2516AVVL12EMXWAK1GE APPLIANCES ZONELINEGE APPLIANCES ZONELINE1 ton12,500 Btu/h · Ducted1.8583%8.117.0CEE 25CEE 26Xcel1217008192
2517AVVS12DCXWAK1GE APPLIANCES ZONELINEGE APPLIANCES ZONELINE1 ton12,500 Btu/h · Ducted1.8582%8.117.0CEE 25CEE 26Xcel1216797480
2518AVVS12ECXWAK1GE APPLIANCES ZONELINEGE APPLIANCES ZONELINE1 ton12,500 Btu/h · Ducted1.8583%8.117.0CEE 25CEE 26Xcel1217008194
2519TFM2G18CHAIR454BGeneralluxGenerallux1.5 tons18,000 Btu/h · Non-ducted2.0080%10.524.0CEE 25CEE 26Xcel1216765715
2520TFM3G27CHAIR454BGeneralluxGenerallux2.5 tons27,000 Btu/h · Non-ducted2.0071%10.524.0CEE 25CEE 26Xcel1216765716
2521TFM4G36CHAIR454BGeneralluxGenerallux3 tons35,000 Btu/h · Non-ducted2.0072%10.022.5CEE 25CEE 26Xcel1216765717
2522TFM5G42CHAIR454BGeneralluxGenerallux3.5 tons42,000 Btu/h · Non-ducted2.0071%10.022.0CEE 25CEE 26Xcel1216765718
2523THH12E2S25NAR454OGeneralluxwith ductless indoor unit THH12E2S25NAR454IGenerallux1 ton12,000 Btu/h · Non-ducted1.80100%10.525.0CEE 25CEE 26Xcel1216765712
2524THH18E2S24NAR454OGeneralluxwith ductless indoor unit THH18E2S24NAR454IGenerallux1.5 tons18,000 Btu/h · Non-ducted1.8099%10.023.5CEE 25CEE 26Xcel1216765713
2525THH24E2S23NAR454OGeneralluxwith ductless indoor unit THH24E2S23NAR454IGenerallux2 tons24,000 Btu/h · Non-ducted1.8093%10.022.5CEE 25CEE 26Xcel1216765714

Explore qualifying models by COP at 5°F