Skip to content

CEE 2026 Tier 1 (Split ASHP): 6,849 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
6,849
Qualifying certifications
201,045
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,218 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,237
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,153 rated models · median 72%87% of rated models reach 50% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,400
75 to under 80%1,157
80 to under 85%798
85 to under 90%375
90 to under 95%719
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF212,299 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0383
8.0 to under 8.3720
8.3 to under 8.5177
8.5 to under 8.81,449
8.8 to under 9.0196
9.0 to under 9.31,501
9.3 to under 9.5132
9.5 to under 9.81,369
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,323 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,103
15.5 to under 16.0282
16.0 to under 16.5623
16.5 to under 17.0188
17.0 to under 17.5848
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5916
20.5 to under 21.0160
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER212,319 rated models · median 11.6At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0213
9.0 to under 9.5700
9.5 to under 10.0831
10.0 to under 10.5880
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,870
12.5 to under 13.0949
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.6
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.9% · 2,869 of 4,712
2 tons66.2% · 1,157 of 1,747
2.5–3 tons54.6% · 1,485 of 2,722
3.5–4.5 tons44.4% · 1,193 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.6%1,975 / 6,060
Non-ducted67.8%2,765 / 4,081
Ducted and non-ducted96.5%2,109 / 2,185

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree572 of 71779.8%
Midea403 of 54673.8%
Carrier288 of 81635.3%
BlueRidge141 of 19273.4%
Lennox137 of 33141.4%
Daikin137 of 39434.8%
TCL134 of 17775.7%
Trane133 of 36336.6%
Mitsubishi Electric126 of 15680.8%
Hisense122 of 16175.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 255 of 274
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
6351TV3H27FM22X454VENTAGEN · TPROVENTAGEN2.5 tons27,000 Btu/h · Non-ducted2.0071%10.524.0CEE 25CEE 26XcelES CC1218327242
6352TV4H36FM21X454VENTAGEN · TPROVENTAGEN3 tons35,000 Btu/h · Non-ducted2.0072%10.022.5CEE 25CEE 26XcelES CC1218327243
6353TV5H42FM20X454VENTAGEN · TPROVENTAGEN3.5 tons42,000 Btu/h · Non-ducted2.0071%10.022.0CEE 25CEE 26XcelES CC1218327244
6354D5CLHAH36AAKViessmann · D5C Serieswith ducted air handler D5FLDAH36XHKViessmann3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.8CEE 25CEE 26XcelES CC4217178811
6355D5CLHAH48AAKViessmann · D5C Serieswith ducted air handler D5FLAAH48XAKViessmann4 tons48,000 Btu/h · Ducted and non-ducted2.0092%10.217.0CEE 25CEE 26XcelES CC4217178761
6356D5CMHAH18CAKViessmann · D5C SeriesViessmann1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.525.0CEE 25CEE 26XcelES CC3217178817
6357D5CMHAH24DAKViessmann · D5C SeriesViessmann2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.024.0CEE 25CEE 26XcelES CC3217178820
6358D5CMHAH30EAKViessmann · D5C SeriesViessmann2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00116%10.724.0CEE 25CEE 26XcelES CC3217178823
6359D5CMHAH36EAKViessmann · D5C SeriesViessmann3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.1CEE 25CEE 26XcelES CC3217178826
6360D5CMHAH48FAKViessmann · D5C SeriesViessmann4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.323.0CEE 25CEE 26XcelES CC3217178829
6361D5CMHAH55FAKViessmann · D5C SeriesViessmann4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1087%10.720.2CEE 25CEE 26XcelES CC3217178833
6362D5CSHAH06AAKViessmann · D5C Serieswith ductless indoor unit D5FSHAH06XAKViessmann0.5 tons6,000 Btu/h · Non-ducted2.40110%14.825.7CEE 25CEE 26CEE AdvXcelDOEES CC2217178781
6363D5CSHAH09AAKViessmann · D5C Serieswith ducted air handler D5FSDAH12XAKViessmann1 ton9,000 Btu/h · Ducted and non-ducted1.89112%12.521.5CEE 25CEE 26XcelES CC6217178787
6364D5CSHAH12AAKViessmann · D5C Serieswith ductless indoor unit D5FSOAH12XAKViessmann1 ton12,000 Btu/h · Ducted and non-ducted1.9992%10.223.0CEE 25CEE 26XcelES CC6217178790
6365D5CSHAH18AAKViessmann · D5C Serieswith ducted air handler D5FSAAH18XBKViessmann1.5 tons18,000 Btu/h · Ducted and non-ducted2.2092%10.118.2CEE 25CEE 26XcelES CC8217178755
6366D5CSHAH24AAKViessmann · D5C Serieswith ductless indoor unit D5FSHAH24XAKViessmann2 tons24,000 Btu/h · Ducted and non-ducted2.3483%13.521.2CEE 25CEE 26XcelES CC5217178802
6367D5CSHAH33AAKViessmann · D5C Serieswith ducted air handler D5FSAAH36XBKViessmann3 tons33,000 Btu/h · Ducted and non-ducted2.0097%10.016.7CEE 25CEE 26XcelES CC2217178757
6368D5CSRAH30AAKViessmann · D5C Serieswith ducted air handler D5FSAAH30XBKViessmann2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.817.0CEE 25CEE 262217178758
6369D5CUHAH18AAKViessmann · D5C Serieswith ducted air handler D5FUHAH24XAKViessmann1.5 tons18,000 Btu/h · Ducted2.12103%10.219.0CEE 25CEE 26CEE AdvXcelDOEES CC5217178772
6370D5CUHAH18AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0BViessmann1.5 tons18,300 Btu/h · Ducted1.9288%8.516.0CEE 25CEE 26XcelES CC3218475392
6371D5CUHAH18AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0BViessmann1.5 tons18,300 Btu/h · Ducted1.9288%8.516.0CEE 25CEE 26Xcel3217753141
6372D5CUHAH24AAKViessmann · D5C Serieswith ducted air handler D5FUHAH24XAKViessmann2 tons24,000 Btu/h · Ducted2.1486%10.018.7CEE 25CEE 26XcelES CC7217178765
6373D5CUHAH24AAK+KSAIC0701230VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0BViessmann2 tons23,600 Btu/h · Ducted2.0484%9.517.5CEE 25CEE 26XcelES CC2218475400
6374D5CUHAH24AAK+TIC2025-0016VIESSMANN · Crossover Heat Pumpwith ducted air handler FTMA5X24L0BViessmann2 tons23,600 Btu/h · Ducted2.0484%9.517.5CEE 25CEE 26Xcel2217753142
6375D5CUHAH30AAKViessmann · D5C Serieswith ducted air handler D5MUWAQ30XA3Viessmann2.5 tons30,000 Btu/h · Ducted2.00100%10.217.5CEE 25CEE 26XcelES CC6218668523

Explore qualifying models by COP at 5°F