CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
7,576
Qualifying certifications
217,907
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%88% of rated models reach 50% (the lowest path) on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.076% of rated models reach 8 (the lowest path) on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.170% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.5At least 84% of rated models reach 9.8 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.3% · 3,270 of 5,427
2 tons65.9% · 1,279 of 1,941
2.5 to 3 tons54.8% · 1,612 of 2,942
3.5 to 4.5 tons44.6% · 1,264 of 2,834
5 tons and up31.8% · 151 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.8%2,113 / 6,438
Non-ducted66.3%3,223 / 4,861
Ducted and non-ducted96.6%2,240 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea412 of 55574.2%
Carrier313 of 84637%
Daikin145 of 41035.4%
TCL144 of 19275%
BlueRidge142 of 19473.2%
Lennox139 of 34140.8%
Trane134 of 37036.2%
York130 of 23954.4%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 274 of 304
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
6826A5HL5024A1000AARUNTRU · A5HL5with ducted air handler A5AHV002A1B3Trane2 tons23,000 Btu/h · Ducted1.7578%8.116.0CEE 25CEE 26XcelES CC8216439103
6827A5HL5036A1RUNTRUwith ducted air handler CM36B4J+TDRTrane2.5 tons28,400 Btu/h · Ducted1.97109%8.114.3CEE 25CEE 26XcelES CC164218034123
6828A5HL5036A1000AARUNTRU · A5HL5with ducted air handler A5AHV004A1D3Trane3 tons34,000 Btu/h · Ducted1.7579%8.116.0CEE 25CEE 26XcelES CC8216439104
6829A5HL5048A1AMERISTAR · A5HL5with indoor coil 5TXCB006AS3 and furnace A952V060BU4SBTrane3.5 tons41,000 Btu/h · Ducted1.8080%8.115.2CEE 25CEE 26XcelES CC193217162406
6830A5HL5048A1000AARUNTRU · A5HL5with ducted air handler A5AHV006A1D3Trane4 tons46,000 Btu/h · Ducted1.7579%8.116.0CEE 25CEE 26XcelES CC8216439106
6831A5HP5024A1AMERISTARwith indoor coil D(A,C,E)36C3J+TDR and furnace A951X060BU4SATrane2 tons21,600 Btu/h · Ducted2.7968%8.515.2CEE 25CEE 261,026217084183
6832A5HP5030A1RUNTRUwith indoor coil D(A,C,E)36C3J+TDR and furnace A801X080CM5SDTrane2 tons26,200 Btu/h · Ducted2.7768%7.814.8CEE 25CEE 26860217083538
6833A5HP5036A1RUNTRUwith ducted air handler DP37D4J+TDRTrane2.5 tons32,400 Btu/h · Ducted3.0270%8.515.2CEE 25CEE 26Xcel1,057218854191
6834A5HP5042A1RUNTRUwith indoor coil D(A,C,E)48C3J+TDR and furnace A801X080BM4TDTrane3 tons36,600 Btu/h · Ducted2.7964%8.115.5CEE 25CEE 261,537217083968
6835A5HP5048A1RUNTRUwith ducted air handler DM60B4J+TDRTrane3.5 tons42,000 Btu/h · Ducted2.6965%7.815.2CEE 25CEE 26824216619453
6836M3THS2209A91NARunTru · CXVwith ductless indoor unit M3MHW2209A9N0ATrane1 ton9,000 Btu/h · Non-ducted1.7576%9.523.5CEE 25CEE 26Xcel2212586155
6837M3THS2212A91NARunTru · CXVwith ductless indoor unit M3MHW2212A9N0ATrane1 ton12,000 Btu/h · Non-ducted1.7575%9.523.0CEE 25CEE 26Xcel2212586156
6838M5THM2318A12NA*RunTru · 23U MultiTrane1.5 tons18,000 Btu/h · Non-ducted2.0080%10.524.0CEE 25CEE 26XcelES CC2218067082
6839M5THM2327A13NA*RunTru · 23U MultiTrane2.5 tons27,000 Btu/h · Non-ducted2.0071%10.524.0CEE 25CEE 26XcelES CC2218067083
6840M5THM2336A14NA*RunTru · 23U MultiTrane3 tons35,000 Btu/h · Non-ducted2.0072%10.022.5CEE 25CEE 26XcelES CC2218067084
6841M5THM2342A15NA*RunTru · 23U MultiTrane3.5 tons42,000 Btu/h · Non-ducted2.0071%10.022.0CEE 25CEE 26XcelES CC2218067085
6842M5THS1909A11NA*RunTruwith ductless indoor unit M5MHWUN09B1N0ATrane1 ton9,000 Btu/h · Non-ducted1.9071%9.519.0CEE 25CEE 26Xcel2218067098
6843M5THS1909A11NAARunTruwith ductless indoor unit M5MHWUN09A1N0AATrane1 ton9,000 Btu/h · Non-ducted1.8471%9.519.0CEE 25CEE 26Xcel2215385442
6844M5THS1912A11NA*RunTruwith ductless indoor unit M5MHWUN12B1N0ATrane1 ton12,000 Btu/h · Non-ducted2.1072%10.019.0CEE 25CEE 26Xcel2218067099
6845M5THS1912A11NAARunTruwith ductless indoor unit M5MHWUN12A1N0AATrane1 ton12,000 Btu/h · Non-ducted2.1072%10.019.0CEE 25CEE 26Xcel2215385443
6846M5THS1918A11NA*RunTruwith ductless indoor unit M5MHWUN18B1N0ATrane1.5 tons18,000 Btu/h · Non-ducted1.8072%10.019.0CEE 25CEE 26Xcel2218067100
6847M5THS1918A11NAARunTruwith ductless indoor unit M5MHWUN18A1N0AATrane1.5 tons18,000 Btu/h · Non-ducted1.8072%10.019.0CEE 25CEE 26Xcel2215385444
6848M5THS1924A11NA*RunTruwith ductless indoor unit M5MHWUN24B1N0ATrane2 tons23,000 Btu/h · Non-ducted1.8076%9.519.0CEE 25CEE 26Xcel2218067101
6849M5THS1924A11NAARunTruwith ductless indoor unit M5MHWUN24A1N0AATrane2 tons23,000 Btu/h · Non-ducted1.8076%9.519.0CEE 25CEE 26Xcel2215385445
6850M5THS2309A11NA*RunTru · 23U Serieswith ductless indoor unit M5MHWUN09B1N0ATrane1 ton9,000 Btu/h · Non-ducted1.8471%9.523.0CEE 25CEE 26XcelES CC2218067090

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter