Both views use the same certified data. This device remembers your choice.
CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 55.6%
- Qualifying models
- 7,576
- Qualifying certifications
- 217,907
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.3% · 3,270 of 5,427
- 2 tons65.9% · 1,279 of 1,941
- 2.5 to 3 tons54.8% · 1,612 of 2,942
- 3.5 to 4.5 tons44.6% · 1,264 of 2,834
- 5 tons and up31.8% · 151 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.3% · 3,270 of 5,427 |
| 2 tons | 65.9% · 1,279 of 1,941 |
| 2.5 to 3 tons | 54.8% · 1,612 of 2,942 |
| 3.5 to 4.5 tons | 44.6% · 1,264 of 2,834 |
| 5 tons and up | 31.8% · 151 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.8% | 2,113 / 6,438 |
| Non-ducted | 66.3% | 3,223 / 4,861 |
| Ducted and non-ducted | 96.6% | 2,240 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 412 of 555 | 74.2% |
| Carrier | 313 of 846 | 37% |
| Daikin | 145 of 410 | 35.4% |
| TCL | 144 of 192 | 75% |
| BlueRidge | 142 of 194 | 73.2% |
| Lennox | 139 of 341 | 40.8% |
| Trane | 134 of 370 | 36.2% |
| York | 130 of 239 | 54.4% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 7301HH824E2S12COLEMANwith indoor coil D(A,C,E)37E2K+TDR and furnace TM9E060B12MP12 | York | 1.5 tons20,600 Btu/h · Ducted | 2.93 | 68% | 9.0 | 15.5 | CEE 25CEE 26XcelES CC | 9,106 | 218770775 |
| 7302HH836E2S11YORKwith indoor coil D(A,C,E)36B4K+TDR and furnace Y81E080C20LMPS1 | York | 3 tons33,200 Btu/h · Ducted | 3.08 | 90% | 8.5 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 8,624 | 217027554 |
| 7303HH836E2S12COLEMANwith indoor coil D(A,C,E)37E3K+TDR and furnace Z8ET100C20LMPS1 | York | 2.5 tons32,000 Btu/h · Ducted | 3.10 | 68% | 9.0 | 17.5 | CEE 25CEE 26XcelES CC | 7,330 | 218772624 |
| 7304HH860E2S11YORKwith ducted air handler L(E,G)M48HJ | York | 4 tons46,500 Btu/h · Ducted | 2.90 | 77% | 9.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9,473 | 217753023 |
| 7305HH860E2S12COLEMANwith indoor coil D(A,C,E)61B4K+TDR and furnace Z8ES130D20LMPS1 | York | 4 tons50,000 Btu/h · Ducted | 3.03 | 72% | 7.5 | 17.5 | CEE 25CEE 26XcelES CC | 11,233 | 218774462 |
| 7306NONLIST-18K-HP-W-YORKYORKwith ducted air handler NONLIST-18K-HP-I-YORK | York | 1.5 tons18,000 Btu/h · Ducted | 1.80 | 100% | 10.5 | 16.8 | CEE 25CEE 26Xcel | 1 | 219137387 |
| 7307PH9E36N00D21CHAMPION HEATING AND COOLING · PH9 | York | 3 tons34,200 Btu/h · Ducted | 1.80 | 64% | 8.1 | 18.0 | CEE 25CEE 26 | 5 | 218450294 |
| 7308PH9E60N00D21CHAMPION HEATING AND COOLING · PH9 | York | 5 tons57,000 Btu/h · Ducted | 1.85 | 70% | 9.0 | 19.0 | CEE 25CEE 26XcelES CC | 5 | 218450295 |
| 7309RH630E2S11GUARDIAN · LX SERIESwith indoor coil CTM36C5ADS1 and furnace RL18080C16MPS1 | York | 2.5 tons30,400 Btu/h · Ducted | 2.40 | 52% | 8.1 | 17.0 | CEE 25CEE 26 | 126 | 218418047 |
| 7310UMC18CN23STG1GUARDIAN · UMULTI | York | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.16 | 104% | 9.4 | 17.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 215747714 |
| 7311UMC24CN23STG1GUARDIAN · UMULTI | York | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.88 | 102% | 8.8 | 18.0 | CEE 25CEE 26XcelES CC | 9 | 215747716 |
| 7312UMC36CN23STG1GUARDIAN · UMULTI | York | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.94 | 101% | 10.0 | 22.0 | CEE 25CEE 26XcelES CC | 9 | 215747722 |
| 7313UMC48CN23STG1GUARDIAN · UMULTI | York | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 79% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 9 | 215747719 |
| 7314UPC09CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI09HW23STG1 | York | 1 ton9,000 Btu/h · Ducted and non-ducted | 1.80 | 111% | 10.5 | 22.0 | CEE 25CEE 26XcelES CC | 9 | 215439626 |
| 7315UPC12CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI12HW23STG1 | York | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.88 | 100% | 10.5 | 22.0 | CEE 25CEE 26XcelES CC | 9 | 215439627 |
| 7316UPC18CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI18CS23STG1 | York | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 2.26 | 100% | 10.0 | 20.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 9 | 216019852 |
| 7317UPC24CN23STG1GUARDIANwith ducted air handler JHE24B5AC2SS1 | York | 2 tons24,000 Btu/h · Ducted and non-ducted | 3.55 | 81% | 9.5 | 18.0 | CEE 25CEE 26XcelES CC | 34 | 216409634 |
| 7318UPC36CN23STG1GUARDIAN · UPACwith ductless indoor unit UNI36CS23STG1 | York | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.07 | 100% | 9.5 | 19.5 | CEE 25CEE 26XcelES CC | 20 | 215449562 |
| 7319UPC36CN23STG1*GUARDIAN · UPACwith ductless indoor unit UNI36HW23STG1 | York | 3 tons36,000 Btu/h · Non-ducted | 1.88 | 100% | 10.0 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 216346013 |
| 7320UPC48CN23STG1GUARDIAN · UPACwith ducted air handler UNI48DT23STG1 | York | 3.5 tons44,000 Btu/h · Ducted and non-ducted | 2.00 | 100% | 9.5 | 19.5 | CEE 25CEE 26XcelES CC | 15 | 215441405 |
| 7321URC09CN15STG1GUARDIAN · URACwith ductless indoor unit URD09HW15STG1 | York | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 92% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 215270360 |
| 7322URC09CN23STG1GUARDIAN · URACwith ductless indoor unit UNI09HW23STG1 | York | 1 ton9,000 Btu/h · Non-ducted | 2.09 | 100% | 11.0 | 25.0 | CEE 25CEE 26XcelES CC | 3 | 214803264 |
| 7323URC12CN15STG1GUARDIAN · URACwith ductless indoor unit URD12HW15STG1 | York | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 215270361 |
| 7324URC12CN23STG1GUARDIAN · URACwith ductless indoor unit UNI12HW23STG1 | York | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 92% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 3 | 214803265 |
| 7325URC18CN23STG1GUARDIAN · URACwith ductless indoor unit UNI18HW23STG1 | York | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 214803266 |