Both views use the same certified data. This device remembers your choice.
CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps
The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.
Simple view, for homeowners: top picks by size and what each rating measures →
Consortium for Energy EfficiencyData as of updated · sources
- Share of models
- 55.6%
- Qualifying models
- 7,576
- Qualifying certifications
- 217,907
- Paths
- 2
Criteria
| Path | SEER2 | EER2 | HSPF2 | COP@5°F | Cap. 5/47 |
|---|---|---|---|---|---|
| Path A (heating-dominated) | ≥ 16 | ≥ 9.8 | ≥ 8.5 | ≥ 1.75 | ≥ 65% |
| Path B (cooling-dominated / dual fuel) | ≥ 16 | ≥ 11 | ≥ 8 | ≥ 1.75 | ≥ 50% |
Source: Consortium for Energy Efficiency
Where the thresholds fall
Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
Show the data as a table
| COP@5°F range | Models |
|---|---|
| Below 1.40 | 13 |
| 1.40 to under 1.50 | 81 |
| 1.50 to under 1.60 | 190 |
| 1.60 to under 1.70 | 389 |
| 1.70 to under 1.80 | 1,291 |
| 1.80 to under 1.90 | 2,581 |
| 1.90 to under 2.00 | 1,532 |
| 2.00 to under 2.10 | 2,675 |
| 2.10 to under 2.20 | 1,457 |
| 2.20 to under 2.30 | 883 |
| 2.30 to under 2.40 | 548 |
| 2.40 to under 2.50 | 284 |
| 2.50 to under 2.60 | 246 |
| 2.60 to under 2.70 | 139 |
| 2.70 to under 2.80 | 81 |
| 2.80 to under 2.90 | 52 |
| 2.90 to under 3.00 | 33 |
| 3.00 and above | 39 |
| Baseline: median | 2.00 |
| Baseline: CEE 2026 1.75 | 1.75 |
Source: AHRI Directory · as of
Show the data as a table
| Cap. 5/47 range | Models |
|---|---|
| Below 30% | 51 |
| 30 to under 35% | 29 |
| 35 to under 40% | 340 |
| 40 to under 45% | 483 |
| 45 to under 50% | 574 |
| 50 to under 55% | 704 |
| 55 to under 60% | 666 |
| 60 to under 65% | 782 |
| 65 to under 70% | 892 |
| 70 to under 75% | 2,697 |
| 75 to under 80% | 1,230 |
| 80 to under 85% | 910 |
| 85 to under 90% | 410 |
| 90 to under 95% | 798 |
| 95 to under 100% | 623 |
| 100 to under 105% | 825 |
| 105 to under 110% | 148 |
| 110 to under 115% | 151 |
| 115 to under 120% | 23 |
| 120 to under 125% | 38 |
| 125% and above | 59 |
| Baseline: median | 72% |
| Baseline: Path B 50% | 50% |
| Baseline: Path A 65% | 65% |
Source: AHRI Directory · as of
Show the data as a table
| HSPF2 range | Models |
|---|---|
| Below 6.5 | 43 |
| 6.5 to under 6.8 | 1,016 |
| 6.8 to under 7.0 | 69 |
| 7.0 to under 7.3 | 568 |
| 7.3 to under 7.5 | 18 |
| 7.5 to under 7.8 | 1,201 |
| 7.8 to under 8.0 | 382 |
| 8.0 to under 8.3 | 838 |
| 8.3 to under 8.5 | 188 |
| 8.5 to under 8.8 | 1,687 |
| 8.8 to under 9.0 | 198 |
| 9.0 to under 9.3 | 1,671 |
| 9.3 to under 9.5 | 142 |
| 9.5 to under 9.8 | 1,624 |
| 9.8 to under 10.0 | 312 |
| 10.0 to under 10.3 | 1,826 |
| 10.3 to under 10.5 | 237 |
| 10.5 to under 10.8 | 656 |
| 10.8 to under 11.0 | 82 |
| 11.0 to under 11.3 | 316 |
| 11.3 to under 11.5 | 60 |
| 11.5 to under 11.8 | 131 |
| 11.8 to under 12.0 | 21 |
| 12.0 to under 12.3 | 30 |
| 12.3 to under 12.5 | 2 |
| 12.5 to under 12.8 | 96 |
| 12.8 to under 13.0 | 1 |
| 13.0 to under 13.3 | 24 |
| 13.3 to under 13.5 | 10 |
| 13.5 to under 13.8 | 46 |
| 13.8 to under 14.0 | 37 |
| 14.0 and above | 63 |
| Baseline: median | 9.0 |
| Baseline: Path B 8 | 8.0 |
| Baseline: Path A 8.5 | 8.5 |
Source: AHRI Directory · as of
Show the data as a table
| SEER2 range | Models |
|---|---|
| Below 12.5 | 54 |
| 12.5 to under 13.0 | 28 |
| 13.0 to under 13.5 | 910 |
| 13.5 to under 14.0 | 372 |
| 14.0 to under 14.5 | 1,115 |
| 14.5 to under 15.0 | 198 |
| 15.0 to under 15.5 | 1,131 |
| 15.5 to under 16.0 | 305 |
| 16.0 to under 16.5 | 625 |
| 16.5 to under 17.0 | 221 |
| 17.0 to under 17.5 | 982 |
| 17.5 to under 18.0 | 245 |
| 18.0 to under 18.5 | 808 |
| 18.5 to under 19.0 | 403 |
| 19.0 to under 19.5 | 868 |
| 19.5 to under 20.0 | 194 |
| 20.0 to under 20.5 | 1,156 |
| 20.5 to under 21.0 | 179 |
| 21.0 to under 21.5 | 851 |
| 21.5 to under 22.0 | 172 |
| 22.0 to under 22.5 | 571 |
| 22.5 to under 23.0 | 220 |
| 23.0 to under 23.5 | 729 |
| 23.5 to under 24.0 | 120 |
| 24.0 to under 24.5 | 340 |
| 24.5 to under 25.0 | 157 |
| 25.0 to under 25.5 | 302 |
| 25.5 to under 26.0 | 81 |
| 26.0 to under 26.5 | 44 |
| 26.5 to under 27.0 | 19 |
| 27.0 to under 27.5 | 69 |
| 27.5 to under 28.0 | 23 |
| 28.0 to under 28.5 | 7 |
| 28.5 to under 29.0 | 1 |
| 29.0 to under 29.5 | 15 |
| 29.5 to under 30.0 | 23 |
| 30.0 to under 30.5 | 23 |
| 30.5 and above | 54 |
| Baseline: median | 18.1 |
| Baseline: CEE 2026 16 | 16.0 |
Source: AHRI Directory · as of
Show the data as a table
| EER2 range | Models |
|---|---|
| Below 8.0 | 4 |
| 8.0 to under 8.5 | 112 |
| 8.5 to under 9.0 | 248 |
| 9.0 to under 9.5 | 805 |
| 9.5 to under 10.0 | 1,039 |
| 10.0 to under 10.5 | 975 |
| 10.5 to under 11.0 | 1,516 |
| 11.0 to under 11.5 | 1,966 |
| 11.5 to under 12.0 | 1,967 |
| 12.0 to under 12.5 | 2,024 |
| 12.5 to under 13.0 | 985 |
| 13.0 to under 13.5 | 988 |
| 13.5 to under 14.0 | 242 |
| 14.0 to under 14.5 | 299 |
| 14.5 to under 15.0 | 123 |
| 15.0 to under 15.5 | 189 |
| 15.5 to under 16.0 | 6 |
| 16.0 to under 16.5 | 37 |
| 16.5 to under 17.0 | 23 |
| 17.0 and above | 66 |
| Baseline: median | 11.5 |
| Baseline: Path A 9.8 | 9.8 |
| Baseline: Path B 11 | 11.0 |
Source: AHRI Directory · as of
Qualification by size
- Up to 1.5 tons60.3% · 3,270 of 5,427
- 2 tons65.9% · 1,279 of 1,941
- 2.5 to 3 tons54.8% · 1,612 of 2,942
- 3.5 to 4.5 tons44.6% · 1,264 of 2,834
- 5 tons and up31.8% · 151 of 475
Show the data as a table
| Group | Qualifying share |
|---|---|
| Up to 1.5 tons | 60.3% · 3,270 of 5,427 |
| 2 tons | 65.9% · 1,279 of 1,941 |
| 2.5 to 3 tons | 54.8% · 1,612 of 2,942 |
| 3.5 to 4.5 tons | 44.6% · 1,264 of 2,834 |
| 5 tons and up | 31.8% · 151 of 475 |
Qualification by duct type
| Type | Share | Qualifying / total |
|---|---|---|
| Ducted | 32.8% | 2,113 / 6,438 |
| Non-ducted | 66.3% | 3,223 / 4,861 |
| Ducted and non-ducted | 96.6% | 2,240 / 2,320 |
Manufacturers with the most qualifying models
Among manufacturers with at least 5 models.
| Manufacturer | Qualifying | Share of its models |
|---|---|---|
| Gree | 584 of 729 | 80.1% |
| Midea | 412 of 555 | 74.2% |
| Carrier | 313 of 846 | 37% |
| Daikin | 145 of 410 | 35.4% |
| TCL | 144 of 192 | 75% |
| BlueRidge | 142 of 194 | 73.2% |
| Lennox | 139 of 341 | 40.8% |
| Trane | 134 of 370 | 36.2% |
| York | 130 of 239 | 54.4% |
| Mitsubishi Electric | 126 of 156 | 80.8% |
Qualifying models
Sorted by manufacturer and model. Use Explore for other sorts and filters.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|
| 7326URC24CN23STG1GUARDIAN · URACwith ductless indoor unit UNI24HW23STG1 | York | 2 tons24,000 Btu/h · Non-ducted | 1.84 | 83% | 9.5 | 22.5 | CEE 25CEE 26XcelES CC | 3 | 214803267 |
| 7327XD524E2D11CHAMPION HEATING AND COOLING · XD5with ducted air handler JDE24E5XX2DS1 | York | 2 tons24,000 Btu/h · Ducted | 1.84 | 72% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 40 | 218450290 |
| 7328XD536E2D11CHAMPION HEATING AND COOLING · XD5with ducted air handler JDE36E5XX2DS1 | York | 3 tons34,200 Btu/h · Ducted | 1.90 | 65% | 8.5 | 17.0 | CEE 25CEE 26XcelES CC | 68 | 218619098 |
| 7329XD560E2D11CHAMPION HEATING AND COOLING · XD5with indoor coil CDM48C5XXS1 and furnace Y82E080C16LMPS1 | York | 3.5 tons43,000 Btu/h · Ducted | 1.90 | 72% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 84 | 218787931 |
| 7330XDV36E2D11CHAMPION HEATING AND COOLING · XDVwith ducted air handler JDE24E5XX2DS1 | York | 2 tons24,000 Btu/h · Ducted | 2.01 | 73% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 40 | 218450283 |
| 7331XDV60E2D11CHAMPION HEATING AND COOLING · XDVwith ducted air handler JDE48F5XX2DS1 | York | 4 tons47,000 Btu/h · Ducted | 2.00 | 70% | 9.5 | 18.5 | CEE 25CEE 26XcelES CC | 28 | 218450284 |
| 7332XH524E2S11CHAMPION HEATING AND COOLINGwith indoor coil D(A,C,E)36D2K+TDR and furnace Z8ES080B12SMPS1 | York | 2 tons22,600 Btu/h · Ducted | 2.69 | 67% | 7.8 | 15.2 | CEE 25CEE 26 | 909 | 217199867 |
| 7333XH536E2S11CHAMPION HEATING AND COOLINGwith indoor coil D(A,C,E)36B4K+TDR and furnace Z8ET120C20LMPS1 | York | 2.5 tons32,800 Btu/h · Ducted | 3.08 | 67% | 8.1 | 15.2 | CEE 25CEE 26 | 3,218 | 217200158 |
| 7334XH548E2S11CHAMPION HEATING AND COOLINGwith indoor coil D(A,C,E)48D4K+TDR and furnace Z8ET080C16LMPS1 | York | 4 tons45,500 Btu/h · Ducted | 3.04 | 70% | 7.8 | 15.2 | CEE 25CEE 26Xcel | 4,709 | 217200422 |
| 7335XH618E2S11CHAMPION HEATING AND COOLINGwith ducted air handler L(E,F)W30DJ | York | 1.5 tons17,500 Btu/h · Ducted | 2.53 | 64% | 7.5 | 16.0 | CEE 25CEE 26 | 1,764 | 218694278 |
| 7336XH624E2S11CHAMPION HEATING AND COOLINGwith indoor coil C(A,C,D,E)24B3J+TDR and furnace Z9ES080B12SMPS1 | York | 2 tons21,000 Btu/h · Ducted | 2.65 | 61% | 8.1 | 15.5 | CEE 25CEE 26 | 1,724 | 217222612 |
| 7337XH630E2S11LUXAIREwith ducted air handler C(A,C,D,E)36A3Z+TXV+TDR | York | 2 tons26,600 Btu/h · Ducted | 2.59 | 65% | 7.5 | 14.3 | CEE 25CEE 26 | 1,054 | 218856345 |
| 7338XH636E2S11COLEMANwith ducted air handler D(A,C,E)36B4K+JMC20D2SN1+TDR | York | 3 tons34,000 Btu/h · Ducted | 2.96 | 60% | 9.0 | 17.0 | CEE 25CEE 26 | 2,711 | 218015753 |
| 7339XH648E2S11COLEMANwith indoor coil D(A,C,E)60A4K+TDR and furnace Z9ES120D20SMPS1 | York | 3.5 tons44,500 Btu/h · Ducted | 2.91 | 72% | 8.1 | 16.0 | CEE 25CEE 26Xcel | 3,189 | 218448057 |
| 7340XH660E2S11COLEMANwith ducted air handler DM59A4K+JMC20D2SN1+TDR | York | 4.5 tons51,000 Btu/h · Ducted | 2.86 | 65% | 8.2 | 16.0 | CEE 25CEE 26 | 1,535 | 218026324 |
| 7341XH936E2C11COLEMAN · LX SERIESwith ducted air handler JHC36B5AD2SS1+CC | York | 3 tons35,000 Btu/h · Ducted | 2.00 | 93% | 9.0 | 19.0 | CEE 25CEE 26XcelES CC | 823 | 218026877 |
| 7342XH960E2C11COLEMAN · LX SERIESwith ducted air handler JHC48D5CG2SS1+CC | York | 4 tons48,000 Btu/h · Ducted | 2.00 | 95% | 8.5 | 21.0 | CEE 25CEE 26XcelES CC | 829 | 218026835 |
| 7343YD524E2D11YORK · YD5with ducted air handler JDE24E5XX2DS1 | York | 2 tons24,000 Btu/h · Ducted | 1.84 | 72% | 8.5 | 18.0 | CEE 25CEE 26XcelES CC | 6 | 218450367 |
| 7344YD536E2D11YORK · YD5with ducted air handler JDE36E5XX2DS1 | York | 3 tons34,200 Btu/h · Ducted | 1.90 | 65% | 8.5 | 17.0 | CEE 25CEE 26XcelES CC | 12 | 218619077 |
| 7345YD560E2D11YORK · YD5with indoor coil CDM48C5XXS1 and furnace Y82E080C16LMPS1 | York | 3.5 tons43,000 Btu/h · Ducted | 1.90 | 72% | 8.5 | 16.0 | CEE 25CEE 26XcelES CC | 16 | 218787951 |
| 7346YDC36E2D11YORK · YDCwith ducted air handler JDU36F5XX2DS1 | York | 3 tons36,400 Btu/h · Ducted | 2.10 | 100% | 10.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218619070 |
| 7347YDC60E2D11YORK · YDCwith ducted air handler JDU48F5XX2DS1 | York | 4 tons48,500 Btu/h · Ducted | 2.10 | 100% | 10.0 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 7 | 218450357 |
| 7348YDV36E2D11YORK · YDVwith ducted air handler JDE24E5XX2DS1 | York | 2 tons24,000 Btu/h · Ducted | 2.01 | 73% | 9.5 | 20.0 | CEE 25CEE 26XcelES CC | 10 | 218450360 |
| 7349YDV60E2D11YORK · YDVwith ducted air handler JDE48F5XX2DS1 | York | 4 tons47,000 Btu/h · Ducted | 2.00 | 70% | 9.5 | 18.5 | CEE 25CEE 26XcelES CC | 7 | 218450361 |
| 7350YH524E2S11YORKwith ducted air handler L(E,F)W30CJ | York | 2 tons23,600 Btu/h · Ducted | 2.37 | 62% | 7.8 | 15.2 | CEE 25CEE 26 | 256 | 216436783 |