Skip to content

CEE 2026 Tier 1 (Split ASHP): 6,851 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

New to heat pump ratings? The Simple view explains them in plain words →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
6,851
Qualifying certifications
202,812
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F11,219 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+40 above12 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4012
1.40 to under 1.5079
1.50 to under 1.60176
1.60 to under 1.70335
1.70 to under 1.801,180
1.80 to under 1.902,238
1.90 to under 2.001,350
2.00 to under 2.102,426
2.10 to under 2.201,325
2.20 to under 2.30778
2.30 to under 2.40511
2.40 to under 2.50260
2.50 to under 2.60215
2.60 to under 2.70132
2.70 to under 2.8080
2.80 to under 2.9051
2.90 to under 3.0031
3.00 and above40
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F11,154 rated models · median 72%87% of rated models reach 50% (the lowest path) on this rating alone.
+40 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%28
35 to under 40%337
40 to under 45%467
45 to under 50%519
50 to under 55%566
55 to under 60%526
60 to under 65%684
65 to under 70%763
70 to under 75%2,401
75 to under 80%1,156
80 to under 85%798
85 to under 90%375
90 to under 95%720
95 to under 100%580
100 to under 105%757
105 to under 110%151
110 to under 115%148
115 to under 120%27
120 to under 125%41
125 to under 130%19
130% and above40
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF212,304 rated models · median 9.075% of rated models reach 8 (the lowest path) on this rating alone.
+62 above41 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.541
6.5 to under 6.8983
6.8 to under 7.064
7.0 to under 7.3528
7.3 to under 7.515
7.5 to under 7.81,111
7.8 to under 8.0381
8.0 to under 8.3723
8.3 to under 8.5178
8.5 to under 8.81,451
8.8 to under 9.0196
9.0 to under 9.31,500
9.3 to under 9.5132
9.5 to under 9.81,371
9.8 to under 10.0306
10.0 to under 10.31,626
10.3 to under 10.5228
10.5 to under 10.8602
10.8 to under 11.080
11.0 to under 11.3294
11.3 to under 11.559
11.5 to under 11.8122
11.8 to under 12.021
12.0 to under 12.327
12.3 to under 12.52
12.5 to under 12.892
12.8 to under 13.00
13.0 to under 13.323
13.3 to under 13.59
13.5 to under 13.843
13.8 to under 14.034
14.0 and above62
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER212,328 rated models · median 18.068% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.014
13.0 to under 13.5900
13.5 to under 14.0338
14.0 to under 14.51,002
14.5 to under 15.0192
15.0 to under 15.51,101
15.5 to under 16.0284
16.0 to under 16.5624
16.5 to under 17.0188
17.0 to under 17.5849
17.5 to under 18.0214
18.0 to under 18.5680
18.5 to under 19.0393
19.0 to under 19.5745
19.5 to under 20.0182
20.0 to under 20.5917
20.5 to under 21.0162
21.0 to under 21.5783
21.5 to under 22.0162
22.0 to under 22.5508
22.5 to under 23.0197
23.0 to under 23.5661
23.5 to under 24.0111
24.0 to under 24.5294
24.5 to under 25.0151
25.0 to under 25.5286
25.5 to under 26.075
26.0 to under 26.539
26.5 to under 27.018
27.0 to under 27.560
27.5 to under 28.022
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.022
30.0 to under 30.523
30.5 and above54
Baseline: median18.0
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER212,324 rated models · median 11.5At least 85% of rated models reach 9.8 (the lowest path) on this rating alone.
+31 above2 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.02
8.0 to under 8.595
8.5 to under 9.0214
9.0 to under 9.5702
9.5 to under 10.0831
10.0 to under 10.5881
10.5 to under 11.01,359
11.0 to under 11.51,678
11.5 to under 12.01,904
12.0 to under 12.51,869
12.5 to under 13.0951
13.0 to under 13.5914
13.5 to under 14.0232
14.0 to under 14.5274
14.5 to under 15.0114
15.0 to under 15.5179
15.5 to under 16.05
16.0 to under 16.531
16.5 to under 17.023
17.0 to under 17.535
17.5 and above31
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.8% · 2,869 of 4,715
2 tons66.2% · 1,157 of 1,748
2.5–3 tons54.6% · 1,487 of 2,724
3.5–4.5 tons44.4% · 1,193 of 2,687
5 tons and up31.7% · 145 of 458

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.6%1,973 / 6,056
Non-ducted67.7%2,766 / 4,087
Ducted and non-ducted96.5%2,112 / 2,189

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree572 of 71779.8%
Midea403 of 54673.8%
Carrier288 of 81635.3%
BlueRidge141 of 19273.4%
Lennox139 of 33741.2%
Daikin137 of 39434.8%
TCL134 of 17775.7%
Trane133 of 36336.6%
Mitsubishi Electric126 of 15680.8%
Hisense122 of 16175.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 39 of 275
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
951500006877CADET · 500 SeriesCADET2.5 tons28,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%9.519.0CEE 25CEE 26XcelES CC3218471388
952500006878CADET · 500 SeriesCADET3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00106%10.419.4CEE 25CEE 26XcelES CC3218471391
953500006879CADET · 500 SeriesCADET4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0098%10.221.2CEE 25CEE 26XcelES CC3218471393
954500006880CADET · 500 Serieswith ductless indoor unit 500006872CADET1 ton9,000 Btu/h · Non-ducted1.8096%12.526.0CEE 25CEE 26XcelES CC1218471380
955500006881CADET · 500 Serieswith ductless indoor unit 500006873CADET1 ton12,000 Btu/h · Non-ducted1.8096%10.524.0CEE 25CEE 26XcelES CC1218471381
956500006882CADET · 500 Serieswith ductless indoor unit 500006874CADET1.5 tons18,000 Btu/h · Non-ducted2.00100%10.821.7CEE 25CEE 26XcelES CC1218471382
957500006883CADET · 500 Serieswith ductless indoor unit 500006875CADET2 tons23,000 Btu/h · Non-ducted2.0092%13.322.3CEE 25CEE 26XcelES CC1218471383
9584C22SCH09H11CanAir · 4C22 Serieswith ductless indoor unit 4C22SEH09H11CanAir1 ton9,000 Btu/h · Non-ducted1.9665%9.021.5CEE 25CEE 26XcelES CC2215449710
9594C22SCH09H21CanAir · 4C22 Serieswith ductless indoor unit 4C22SEH09H21CanAir1 ton9,000 Btu/h · Non-ducted2.0770%9.121.2CEE 25CEE 26XcelES CC2215449712
9604C22SCH12H11CanAir · 4C Serieswith ductless indoor unit 4C22SEH12H11-PCanAir1 ton12,000 Btu/h · Non-ducted1.8570%8.721.3CEE 25CEE 26XcelES CC2218472387
9614C22SCH12H21CanAirwith ductless indoor unit 4C22SEH12H21CanAir1 ton12,000 Btu/h · Non-ducted1.9167%9.121.3CEE 25CEE 26XcelES CC2215449713
9624C22SCH18H21CanAirwith ductless indoor unit 4C22SEH18H21CanAir1.5 tons18,000 Btu/h · Non-ducted2.1561%9.619.2CEE 25CEE 26XcelES CC2215449714
9634C22SCH24H21CanAir · 4C22 Serieswith ductless indoor unit 4C22SEH24H21CanAir2 tons24,000 Btu/h · Non-ducted2.1471%9.318.7CEE 25CEE 26XcelES CC2215449715
9644C25LCH36H21CanAir · 4C Serieswith ductless indoor unit 4C28LEQ36H21CanAir3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.320.0CEE 25CEE 26XcelES CC3217958951
9654C25LCH48H21CanAir · 4C Serieswith ductless indoor unit 4C28LEQ48H21CanAir4 tons48,000 Btu/h · Ducted and non-ducted2.1181%9.919.0CEE 25CEE 26XcelES CC3217958952
9664C25LCH60H21CanAirwith ducted air handler 4C28LEDH60H21CanAir5 tons58,000 Btu/h · Ducted and non-ducted2.2067%9.717.0CEE 25CEE 262217958971
9674C25MC318H21CanAir · 4C SeriesCanAir1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.3174%9.922.6CEE 25CEE 26XcelES CC3217958985
9684C25MC428H21CanAir · 4C SeriesCanAir2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.525.0CEE 25CEE 26XcelES CC3217958986
9694C25MC536H21CanAir · 4C SeriesCanAir3 tons35,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%10.023.1CEE 25CEE 26XcelES CC3217958989
9704C25MC548H21CanAir · 4C SeriesCanAir4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1081%10.620.4CEE 25CEE 26XcelES CC3217958993
9714C25SCH09H11CanAir · 4C Serieswith ductless indoor unit 4C28SEH09H11CanAir1 ton9,000 Btu/h · Non-ducted2.2272%10.025.4CEE 25CEE 26XcelES CC2217958928
9724C25SCH09H21CanAir · 4C22 Serieswith ductless indoor unit 4C28SEH09H21CanAir1 ton9,000 Btu/h · Ducted and non-ducted2.3780%12.525.8CEE 25CEE 26XcelES CC8215828387
9734C25SCH12H11CanAir · 4C Serieswith ductless indoor unit 4C28SEH12H11CanAir1 ton12,000 Btu/h · Non-ducted2.3364%9.523.4CEE 25CEE 262217958929
9744C25SCH12H21CanAir · 4C Serieswith ductless indoor unit 4C28SEC12H21CanAir1 ton12,000 Btu/h · Ducted and non-ducted2.5174%11.024.6CEE 25CEE 26XcelES CC9217958979
9754C25SCH18H21CanAir · 4C Serieswith ducted air handler 4C28SEDH18H21CanAir1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.320.0CEE 25CEE 26XcelES CC11217958967

Explore qualifying models by COP at 5°F