Skip to content

CEE 2026 Tier 1 (Split ASHP): 7,576 qualifying heat pumps

The 2026 revision of CEE Tier 1, with higher low-temperature capacity requirements than 2025.

Simple view, for homeowners: top picks by size and what each rating measures →

Consortium for Energy EfficiencyData as of updated · sources

Share of models
55.6%
Qualifying models
7,576
Qualifying certifications
217,907
Paths
2

Criteria

A model qualifies when one certification meets every value in at least one row.
PathSEER2EER2HSPF2COP@5°FCap. 5/47
Path A (heating-dominated)≥ 16≥ 9.8≥ 8.5≥ 1.75≥ 65%
Path B (cooling-dominated / dual fuel)≥ 16≥ 11≥ 8≥ 1.75≥ 50%

Source: Consortium for Energy Efficiency

Where the thresholds fall

Every model's representative certification on each rating CEE 2026 checks, with its thresholds drawn. A model must clear every line of one path at once, on one certification, so these single-rating views show each hurdle, not the combined pass rate.
COP at 5°F12,514 rated models · median 2.00At least 84% of rated models reach 1.75 on this rating alone.
+39 above13 below

Show the data as a table
Models per COP at 5°F range
COP@5°F rangeModels
Below 1.4013
1.40 to under 1.5081
1.50 to under 1.60190
1.60 to under 1.70389
1.70 to under 1.801,291
1.80 to under 1.902,581
1.90 to under 2.001,532
2.00 to under 2.102,675
2.10 to under 2.201,457
2.20 to under 2.30883
2.30 to under 2.40548
2.40 to under 2.50284
2.50 to under 2.60246
2.60 to under 2.70139
2.70 to under 2.8081
2.80 to under 2.9052
2.90 to under 3.0033
3.00 and above39
Baseline: median2.00
Baseline: CEE 2026 1.751.75

Source: AHRI Directory · as of

Capacity retention at 5°F12,433 rated models · median 72%88% of rated models reach 50% (the lowest path) on this rating alone.
+59 above51 below

Show the data as a table
Models per Capacity retention at 5°F range
Cap. 5/47 rangeModels
Below 30%51
30 to under 35%29
35 to under 40%340
40 to under 45%483
45 to under 50%574
50 to under 55%704
55 to under 60%666
60 to under 65%782
65 to under 70%892
70 to under 75%2,697
75 to under 80%1,230
80 to under 85%910
85 to under 90%410
90 to under 95%798
95 to under 100%623
100 to under 105%825
105 to under 110%148
110 to under 115%151
115 to under 120%23
120 to under 125%38
125% and above59
Baseline: median72%
Baseline: Path B 50%50%
Baseline: Path A 65%65%

Source: AHRI Directory · as of

HSPF213,595 rated models · median 9.076% of rated models reach 8 (the lowest path) on this rating alone.
+63 above43 below

Show the data as a table
Models per HSPF2 range
HSPF2 rangeModels
Below 6.543
6.5 to under 6.81,016
6.8 to under 7.069
7.0 to under 7.3568
7.3 to under 7.518
7.5 to under 7.81,201
7.8 to under 8.0382
8.0 to under 8.3838
8.3 to under 8.5188
8.5 to under 8.81,687
8.8 to under 9.0198
9.0 to under 9.31,671
9.3 to under 9.5142
9.5 to under 9.81,624
9.8 to under 10.0312
10.0 to under 10.31,826
10.3 to under 10.5237
10.5 to under 10.8656
10.8 to under 11.082
11.0 to under 11.3316
11.3 to under 11.560
11.5 to under 11.8131
11.8 to under 12.021
12.0 to under 12.330
12.3 to under 12.52
12.5 to under 12.896
12.8 to under 13.01
13.0 to under 13.324
13.3 to under 13.510
13.5 to under 13.846
13.8 to under 14.037
14.0 and above63
Baseline: median9.0
Baseline: Path B 88.0
Baseline: Path A 8.58.5

Source: AHRI Directory · as of

SEER213,615 rated models · median 18.170% of rated models reach 16 on this rating alone.
+54 above54 below

Show the data as a table
Models per SEER2 range
SEER2 rangeModels
Below 12.554
12.5 to under 13.028
13.0 to under 13.5910
13.5 to under 14.0372
14.0 to under 14.51,115
14.5 to under 15.0198
15.0 to under 15.51,131
15.5 to under 16.0305
16.0 to under 16.5625
16.5 to under 17.0221
17.0 to under 17.5982
17.5 to under 18.0245
18.0 to under 18.5808
18.5 to under 19.0403
19.0 to under 19.5868
19.5 to under 20.0194
20.0 to under 20.51,156
20.5 to under 21.0179
21.0 to under 21.5851
21.5 to under 22.0172
22.0 to under 22.5571
22.5 to under 23.0220
23.0 to under 23.5729
23.5 to under 24.0120
24.0 to under 24.5340
24.5 to under 25.0157
25.0 to under 25.5302
25.5 to under 26.081
26.0 to under 26.544
26.5 to under 27.019
27.0 to under 27.569
27.5 to under 28.023
28.0 to under 28.57
28.5 to under 29.01
29.0 to under 29.515
29.5 to under 30.023
30.0 to under 30.523
30.5 and above54
Baseline: median18.1
Baseline: CEE 2026 1616.0

Source: AHRI Directory · as of

EER213,614 rated models · median 11.5At least 84% of rated models reach 9.8 (the lowest path) on this rating alone.
+66 above4 below

Show the data as a table
Models per EER2 range
EER2 rangeModels
Below 8.04
8.0 to under 8.5112
8.5 to under 9.0248
9.0 to under 9.5805
9.5 to under 10.01,039
10.0 to under 10.5975
10.5 to under 11.01,516
11.0 to under 11.51,966
11.5 to under 12.01,967
12.0 to under 12.52,024
12.5 to under 13.0985
13.0 to under 13.5988
13.5 to under 14.0242
14.0 to under 14.5299
14.5 to under 15.0123
15.0 to under 15.5189
15.5 to under 16.06
16.0 to under 16.537
16.5 to under 17.023
17.0 and above66
Baseline: median11.5
Baseline: Path A 9.89.8
Baseline: Path B 1111.0

Source: AHRI Directory · as of

Qualification by size

Share of models meeting CEE 2026, by size
Show the data as a table
Share of models meeting CEE 2026, by size
GroupQualifying share
Up to 1.5 tons60.3% · 3,270 of 5,427
2 tons65.9% · 1,279 of 1,941
2.5 to 3 tons54.8% · 1,612 of 2,942
3.5 to 4.5 tons44.6% · 1,264 of 2,834
5 tons and up31.8% · 151 of 475

Qualification by duct type

Models certified only with ducted, only with non-ducted, or with both kinds of indoor unit
TypeShareQualifying / total
Ducted32.8%2,113 / 6,438
Non-ducted66.3%3,223 / 4,861
Ducted and non-ducted96.6%2,240 / 2,320

Manufacturers with the most qualifying models

Among manufacturers with at least 5 models.
Qualifying models and share of each manufacturer’s catalog
ManufacturerQualifyingShare of its models
Gree584 of 72980.1%
Midea412 of 55574.2%
Carrier313 of 84637%
Daikin145 of 41035.4%
TCL144 of 19275%
BlueRidge142 of 19473.2%
Lennox139 of 34140.8%
Trane134 of 37036.2%
York130 of 23954.4%
Mitsubishi Electric126 of 15680.8%

Qualifying models

Sorted by manufacturer and model. Use Explore for other sorts and filters.
Models meeting CEE 2026 Tier 1 (Split ASHP), page 53 of 304
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
1301D5CSRAH30AAKARCOAIRE · D5F Serieswith ducted air handler D5FSAAH30XBKCarrier2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.817.0CEE 25CEE 2629215413032
1302D5CUHAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier1.5 tons17,700 Btu/h · Ducted2.8680%8.516.0CEE 25CEE 26CEE AdvXcelDOEES CC1,298217906663
1303D5CUHAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.0CEE 25CEE 26XcelES CC1,789218483199
1304D5CUHAH18AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.0CEE 25CEE 26XcelES CC1,809217399865
1305D5CUHAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.0CEE 25CEE 26XcelES CC5,137217906665
1306D5CUHAH24AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*BCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.0CEE 25CEE 26XcelES CC4,630218486193
1307D5CUHAH24AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FHMA5*30L*BCarrier2 tons24,200 Btu/h · Ducted2.0683%9.016.0CEE 25CEE 26XcelES CC4,391217635077
1308D5CUHAH30AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2.5 tons28,000 Btu/h · Ducted2.4880%7.815.2CEE 25CEE 26XcelES CC1,069217906667
1309D5CUHAH30AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16ACarrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.5CEE 25CEE 26XcelES CC4,246218490362
1310D5CUHAH30AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith indoor coil EA*5X43M21A and furnace OLV112A16ACarrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.5CEE 25CEE 26XcelES CC4,261217396826
1311D5CUHAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons35,000 Btu/h · Ducted2.1474%8.015.2CEE 25CEE 26XcelES CC209217906668
1312D5CUHAH36AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.5CEE 25CEE 26XcelES CC4,075218495042
1313D5CUHAH36AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.5CEE 25CEE 26XcelES CC4,146217486562
1314D5CUHAH48AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDRCarrier4 tons45,000 Btu/h · Ducted2.4375%8.015.2CEE 25CEE 26XcelES CC234217906669
1315D5CUHAH60AAKTEMPSTARwith ducted air handler D(A,C,E)60B3J+TDRCarrier4 tons45,000 Btu/h · Ducted2.1262%7.515.2CEE 25CEE 26XcelES CC170217906670
1316D5CUHAH60AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler F5MA5*60L*DCarrier4.5 tons55,500 Btu/h · Ducted1.8090%9.015.0CEE 25CEE 26ES CC566218477311
1317D5CUHAH60AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FEVB0060**+NAVA56001CKCarrier4.5 tons53,500 Btu/h · Ducted1.8690%9.014.5CEE 25CEE 26XcelES CC104217969657
1318D5CURAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier1.5 tons17,700 Btu/h · Ducted2.8375%7.816.0CEE 25CEE 26Xcel2,302217906671
1319D5CURAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,200 Btu/h · Ducted2.1061%9.017.0CEE 25CEE 263,118218609651
1320D5CURAH24AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier2 tons23,800 Btu/h · Ducted2.8879%8.516.0CEE 25CEE 26XcelES CC2,844217906673
1321D5CURAH24AAK+KSAIC0701230HEIL · Crossover heat pumpwith ducted air handler FM(C,U)5Z30**ALCarrier2 tons24,800 Btu/h · Ducted2.1482%9.516.0CEE 25CEE 26XcelES CC2,378218498234
1322D5CURAH30AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier2 tons26,600 Btu/h · Ducted2.2166%7.515.2CEE 25CEE 26Xcel2,962217906674
1323D5CURAH36AAKTEMPSTARwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons33,200 Btu/h · Ducted2.5472%8.114.5CEE 25CEE 26XcelES CC2,804217906675
1324D5CURAH48AAKHEIL · Crossover heat pumpwith ducted air handler FTMA5B60L0DCarrier4 tons47,500 Btu/h · Ducted1.8681%8.015.5CEE 25CEE 26XcelES CC650216772706
1325D5CVRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAKCarrier1 ton9,000 Btu/h · Non-ducted2.1670%9.719.0CEE 25CEE 26XcelES CC18215324155

Explore qualifying models by COP at 5°F

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter