Skip to content

Airdach vs AireForce heat pumps

Measured against models of the same size and duct type, AireForce scores higher on 4 of the 6 ratings. Airdach has 43 outdoor models, AireForce has 70 outdoor models. Airdach and AireForce have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Airdach and AireForce on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AireForce scores higher on 4 of the 6 ratings.
  • Airdach
  • AireForce
  • Other ranked manufacturers
AirdachAireForce

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAirdachAireForce
Efficiency index36%median —40%median —
COP at 5°F43% (higher)median 1.9032% (higher)median 1.80
Capacity retention at 5°F29%median 54%41%median 70%
HSPF226%median 7.539%median 8.6
SEER228%median 14.342%median 18.0
EER248% (higher)median 11.442% (higher)median 11.0
Heating capacity at 5°F25%median 12,600 Btu/h42%median 16,200 Btu/h
Outdoor models4370
AHRI certifications73210

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAirdachAireForce
CEE 2025 Tier 1 (Split ASHP)23.3%10 models50%35 models
CEE 2026 Tier 1 (Split ASHP)23.3%10 models48.6%34 models
CEE Advanced Tier (Split ASHP)0%0 models2.9%2 models
Xcel Energy Colorado cold-climate ASHP (2025)30.2%13 models48.6%34 models
DOE Cold Climate Heat Pump Challenge0%0 models2.9%2 models
ENERGY STAR Cold Climate0%0 models17.1%12 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • Airdach
  • AireForce
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAirdachAireForce
Ducted, up to 1.5 tons2 · index 26%4 · index 33%
Ducted, 2 tons5 · index 34%7 · index 34%
Ducted, 2.5 to 3 tons9 · index 35%12 · index 33%
Ducted, 3.5 to 4.5 tons14 · index 45%14 · index 34%
Non-ducted, up to 1.5 tons10 · index 32%19 · index 41%
Non-ducted, 2 tons2 · index 26%6 · index 48%
Non-ducted, 2.5 to 3 tons1 · index 32%11 · index 49%
Non-ducted, 3.5 to 4.5 tonsNone2 · index 59%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAirdachCold-climate score, best modelAireForceCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)50.4(50 is the typical model of its size class)AC-18-HP-E-32with ducted air handler AC-18-AH-E-322 of 4 models qualify · AHRI 218729450
Ducted, 2 tonsNone on this board (0 of 4 models qualify)48.9(50 is the typical model of its size class)DXH24FMK3IH2 of 6 models qualify · AHRI 215746287
Ducted, 2.5 to 3 tons63.4(50 is the typical model of its size class)A4TH36200MV1DGwith ducted air handler A4DH3600ME1DT2 of 10 models qualify · AHRI 21804542377.3(50 is the typical model of its size class) (higher)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH4 of 13 models qualify · AHRI 217138199
Ducted, 3.5 to 4.5 tons69.8(50 is the typical model of its size class)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT2 of 14 models qualify · AHRI 21879704683.9(50 is the typical model of its size class) (higher)UXH48-60MSK3IHwith ducted air handler UMD60MSK3IH3 of 14 models qualify · AHRI 217138201
Non-ducted, up to 1.5 tons43.6(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D37 of 10 models qualify · AHRI 21710199266.1(50 is the typical model of its size class) (higher)AC-18Z-E-M215 of 19 models qualify · AHRI 218729434
Non-ducted, 2 tons15.4(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 2 models qualify · AHRI 21710199168.5(50 is the typical model of its size class) (higher)DXH24FMK3IH4 of 6 models qualify · AHRI 215746281
Non-ducted, 2.5 to 3 tons23.0(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models qualify · AHRI 21710199077.8(50 is the typical model of its size class) (higher)DXH36FMK3IH9 of 11 models qualify · AHRI 215746283
Non-ducted, 3.5 to 4.5 tonsNo models in this size class67.0(50 is the typical model of its size class)DXH42FMK3IH2 of 2 models qualify · AHRI 215746284

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAirdachAll-around score, best modelAireForceAll-around score, best model
Ducted, up to 1.5 tons25.9(50 is the typical model of its size class)ACTH1815NO1-D4with ducted air handler 26UCS(*,E,Q,R,W)*X1 of 2 models have all five ratings · AHRI 21814797849.1(50 is the typical model of its size class) (higher)AC-18-HP-E-32with ducted air handler AC-18-AH-E-324 of 4 models have all five ratings · AHRI 218729450
Ducted, 2 tons35.7(50 is the typical model of its size class)A4TH24152MN1DLwith ducted air handler A4DH2400ME1DT3 of 4 models have all five ratings · AHRI 21833177255.0(50 is the typical model of its size class) (higher)DXH24FMK3IH6 of 6 models have all five ratings · AHRI 215746287
Ducted, 2.5 to 3 tons73.0(50 is the typical model of its size class) (higher)A4TH36200MV1DGwith ducted air handler A4DH3600ME1DT6 of 10 models have all five ratings · AHRI 21804542368.5(50 is the typical model of its size class)UXH24-36MSK3IHwith ducted air handler UMD36MSK3IH13 of 13 models have all five ratings · AHRI 217138199
Ducted, 3.5 to 4.5 tons72.8(50 is the typical model of its size class)A4TH60200MV1DGwith ducted air handler A4DH4800ME1DT8 of 14 models have all five ratings · AHRI 21804542480.0(50 is the typical model of its size class) (higher)UXH48-60MSK3IHwith ducted air handler UMD48MSK3IH14 of 14 models have all five ratings · AHRI 217138200
Non-ducted, up to 1.5 tons47.5(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D37 of 10 models have all five ratings · AHRI 21710199279.1(50 is the typical model of its size class) (higher)DXH09PSK3IHwith ductless indoor unit DHH09PUK3IH19 of 19 models have all five ratings · AHRI 216011727
Non-ducted, 2 tons26.9(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D32 of 2 models have all five ratings · AHRI 21710199173.3(50 is the typical model of its size class) (higher)AC-24Z-E-M36 of 6 models have all five ratings · AHRI 218729435
Non-ducted, 2.5 to 3 tons31.7(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models have all five ratings · AHRI 21710199071.2(50 is the typical model of its size class) (higher)DXH30FMK3IH11 of 11 models have all five ratings · AHRI 215746282
Non-ducted, 3.5 to 4.5 tonsNo models in this size class67.8(50 is the typical model of its size class)DXH42FMK3IH2 of 2 models have all five ratings · AHRI 215746284

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAirdachAireForce
COP at 5°Fbeats 86% · 2.30A4TH42152MN1DLDucted, 3.5 to 4.5 tonsbeats 87% · 2.10DXH36FMK3IHNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 72% · 88%ACSH0919VA1D3Non-ducted, up to 1.5 tonsbeats 94% · 100%UXH48-60MSK3IHDucted, 3.5 to 4.5 tons
HSPF2beats 78% · 9.5A4TH60200MV1DGDucted, 3.5 to 4.5 tonsbeats 87% · 10.0UXH48-60MSK3IHDucted, 3.5 to 4.5 tons
SEER2beats 86% · 20.0A4TH36200MV1DGDucted, 2 tonsbeats 97% · 26.0DXH24PSK3IHNon-ducted, 2 tons
EER2beats 89% · 13.0A4TH36200MV1DGDucted, 2 tonsbeats 95% · 13.0DXH42FMK3IHNon-ducted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 71% · 12,100 Btu/hACSH1820VR1-D3Non-ducted, up to 1.5 tonsbeats 98% · 54,000 Btu/hUXH48-60MSK3IHDucted, 3.5 to 4.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter