AUX vs Rheem heat pumps
Measured against models of the same size and duct type, AUX scores higher on 3 of the 6 ratings. AUX has 189 outdoor models, Rheem has 342 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AUX
- Rheem
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AUX | Rheem |
|---|---|---|
| Efficiency index | 49%median — · 21st ranked | 50%median — · 20th ranked |
| COP at 5°F | 60% (higher)median 2.00 · 7th ranked | 59% (higher)median 2.05 · 11th ranked |
| Capacity retention at 5°F | 51% (higher)median 75% · 15th ranked | 48% (higher)median 63% · 19th ranked |
| HSPF2 | 40%median 9.0 · 25th ranked | 44%median 7.5 · 22nd ranked |
| SEER2 | 48% (higher)median 20.0 · 18th ranked | 42% (higher)median 15.2 · 24th ranked |
| EER2 | 39%median 11.0 · 27th ranked | 41%median 10.6 · 24th ranked |
| Heating capacity at 5°F | 49%median 9,600 Btu/h · 17th ranked | 49%median 19,550 Btu/h · 19th ranked |
| Outdoor models | 189 | 342 |
| AHRI certifications | 223 | 26,697 |
Share of models meeting each standard
| Standard | AUX | Rheem |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 68.3%129 models | 36%123 models |
| CEE 2026 Tier 1 (Split ASHP) | 66.1%125 models | 34.2%117 models |
| CEE Advanced Tier (Split ASHP) | 1.1%2 models | 1.8%6 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 65.6%124 models | 33.9%116 models |
| DOE Cold Climate Heat Pump Challenge | 1.1%2 models | 1.8%6 models |
| ENERGY STAR Cold Climate | 34.9%66 models | 33.6%115 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AUX
- Rheem
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AUX | Rheem |
|---|---|---|
| Ducted, up to 1.5 tons | 6 · index 60% | 33 · index 56% |
| Ducted, 2 tons | 4 · index 59% | 35 · index 42% |
| Ducted, 2.5–3 tons | 9 · index 63% | 90 · index 46% |
| Ducted, 3.5–4.5 tons | 5 · index 61% | 120 · index 49% |
| Ducted, 5 tons and up | None | 32 · index 45% |
| Non-ducted, up to 1.5 tons | 120 · index 46% | 39 · index 60% |
| Non-ducted, 2 tons | 33 · index 52% | 9 · index 54% |
| Non-ducted, 2.5–3 tons | 22 · index 46% | 18 · index 55% |
| Non-ducted, 3.5–4.5 tons | 2 · index 73% | 12 · index 49% |
| Non-ducted, 5 tons and up | None | 2 · index 43% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AUXCold-climate score, best model | RheemCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.4(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models qualify · AHRI 216032437 | 93.7(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I20 of 33 models qualify · AHRI 215864373 |
| Ducted, 2 tons | 62.9(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models qualify · AHRI 216032438 | 85.9(50 is the typical model of its size class) (higher)ML24HP230NEXH-Owith ducted air handler ML24HP230HSDUC-I16 of 34 models qualify · AHRI 215864380 |
| Ducted, 2.5–3 tons | 73.8(50 is the typical model of its size class)ASPR30HPMULO6 of 9 models qualify · AHRI 216032400 | 94.4(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ28 of 90 models qualify · AHRI 218029736 |
| Ducted, 3.5–4.5 tons | 77.1(50 is the typical model of its size class)ASUM42HPMULO5 of 5 models qualify · AHRI 216032440 | 95.2(50 is the typical model of its size class) (higher)RD18AY48AJVCwith indoor coil D(A,C,E)60B4J+TDR and furnace R801V0754A17DZ33 of 121 models qualify · AHRI 218827549 |
| Ducted, 5 tons and up | No models in this size class | 78.0(50 is the typical model of its size class)RP17AY60AJVCwith indoor coil RCFY6024STANM and furnace R801V1255A24UHNAlso sold as SURE SP17AY60AJVC2 of 32 models qualify · AHRI 218160560 |
| Non-ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class)AM2-H18/2DR3BAlso listed as ASUM18HPMULO80 of 120 models qualify · AHRI 214097940 | 94.9(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ductless indoor unit ML06HP2301WYCAS-I30 of 39 models qualify · AHRI 215864386 |
| Non-ducted, 2 tons | 84.6(50 is the typical model of its size class)AM3-H24/2DR3BAlso listed as ASUM24HPMULO16 of 33 models qualify · AHRI 214097943 | 90.0(50 is the typical model of its size class) (higher)ML24HP230NEXH-Owith ductless indoor unit ML24HP230STDCAS-I9 of 9 models qualify · AHRI 215864372 |
| Non-ducted, 2.5–3 tons | 73.4(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models qualify · AHRI 214097941 | 89.3(50 is the typical model of its size class) (higher)ML36HP230LCMH-Owith ductless indoor unit ML36HP230FLO-I15 of 18 models qualify · AHRI 215864403 |
| Non-ducted, 3.5–4.5 tons | 60.1(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models qualify · AHRI 216050942 | 73.6(50 is the typical model of its size class) (higher)ML48HP230MULH-O*Also listed as ML48HP230MULH - O11 of 12 models qualify · AHRI 216623576 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | AUXAll-around score, best model | RheemAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 79.8(50 is the typical model of its size class)ASUM18HPMULO6 of 6 models have all five ratings · AHRI 216032437 | 95.1(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ducted air handler ML06HP230LSDUC-I33 of 33 models have all five ratings · AHRI 215864373 |
| Ducted, 2 tons | 78.2(50 is the typical model of its size class)ASUM24HPMULO4 of 4 models have all five ratings · AHRI 216032438 | 78.8(50 is the typical model of its size class) (higher)ML24HP230NEX-Owith ducted air handler ML24HP230HSDUC-I32 of 32 models have all five ratings · AHRI 215864360 |
| Ducted, 2.5–3 tons | 81.4(50 is the typical model of its size class)ASUM36HPMULO9 of 9 models have all five ratings · AHRI 216032439 | 92.7(50 is the typical model of its size class) (higher)RD18AY36AJVCwith ducted air handler L(E,G)M36FJ68 of 91 models have all five ratings · AHRI 218029736 |
| Ducted, 3.5–4.5 tons | 87.2(50 is the typical model of its size class) (higher)ASUM42HPMULO5 of 5 models have all five ratings · AHRI 216032440 | 86.4(50 is the typical model of its size class)RD18AY48AJVCwith ducted air handler L(E,G)M60IJ69 of 116 models have all five ratings · AHRI 218029742 |
| Ducted, 5 tons and up | No models in this size class | 70.6(50 is the typical model of its size class)RP17AY60AJVCwith ducted air handler RH2TY6024STANNAlso sold as SURE SP17AY60AJVC24 of 38 models have all five ratings · AHRI 218160613 |
| Non-ducted, up to 1.5 tons | 84.2(50 is the typical model of its size class)ASW-H18E3B2/*R3DI-D2with ductless indoor unit ASW-H18E3B2/*R3DI-D2Also listed as ASW-H18E3B2/**R3DI-D2102 of 120 models have all five ratings · AHRI 215218928 | 94.4(50 is the typical model of its size class) (higher)ML06HP230NEXH-Owith ductless indoor unit ML06HP230NEX-I38 of 39 models have all five ratings · AHRI 215864338 |
| Non-ducted, 2 tons | 87.0(50 is the typical model of its size class) (higher)ASW-H24F6A2/ *R3DI-D7with ductless indoor unit ASW-H24F6A2/ *R3DI-D7Also listed as ASW-H24F6A2/**R3DI-D729 of 33 models have all five ratings · AHRI 217115274 | 78.0(50 is the typical model of its size class)ML24HP230CALH-Owith ductless indoor unit ML24HP230CALH-I8 of 8 models have all five ratings · AHRI 215864348 |
| Non-ducted, 2.5–3 tons | 78.5(50 is the typical model of its size class)AM4-H36/2DR3BAlso listed as ASUM36HPMULO18 of 22 models have all five ratings · AHRI 214097941 | 78.6(50 is the typical model of its size class) (higher)ML36HP230MULH-O*Also listed as ML36HP230MULH - O18 of 19 models have all five ratings · AHRI 216623571 |
| Non-ducted, 3.5–4.5 tons | 74.4(50 is the typical model of its size class)ASUM42HPMULO2 of 2 models have all five ratings · AHRI 216050942 | 75.5(50 is the typical model of its size class) (higher)ML48HP230MULH-O*Also listed as ML48HP230MULH - O12 of 12 models have all five ratings · AHRI 216623574 |
| Non-ducted, 5 tons and up | No models in this size class | 58.7(50 is the typical model of its size class)ML55HP230MUL-O*2 of 2 models have all five ratings · AHRI 216623550 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AUX | Rheem |
|---|---|---|
| COP at 5°F | beats 100% · 2.52AFEB09HP115V1CONon-ducted, up to 1.5 tons | beats 100% · 3.08RP15AY48AJ2NDucted, 3.5–4.5 tons |
| Capacity retention at 5°F | beats 99% · 108%AM3-H24/2DR3BAlso listed as ASUM24HPMULONon-ducted, 2 tons | beats 100% · 150%ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 96% · 11.0AM4-H36/2DR3BAlso listed as ASUM36HPMULONon-ducted, 2.5–3 tons | beats 100% · 15.6ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| SEER2 | beats 100% · 22.0ASUM42HPMULODucted, 3.5–4.5 tons | beats 100% · 35.0ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| EER2 | beats 97% · 14.0AMAR24HP230V1CONon-ducted, 2 tons | beats 99% · 17.4ML06HP230CALH-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 21,800 Btu/hAM2-H18/2DR3BAlso listed as ASUM18HPMULONon-ducted, up to 1.5 tons | beats 100% · 35,800 Btu/hRP15AY30AJ2NDucted, 2 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- AUX (median, middle 50%)
- Rheem (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,130 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,130 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,130 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,130 | 2.8 | 3.01 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,130 | 2 | 2.14 | 2.3 | 2.42 | 2.61 |
| All rated models, 5°F | 6,130 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 100% | 100% | 100% | 100% | 100% |
| AUX, 17°F | 65 | 67% | 70% | 73% | 79% | 85% |
| AUX, 5°F | 65 | 62% | 65% | 70% | 73% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AUX, 47°F | 65 | 2.93 | 3.18 | 3.3 | 3.52 | 3.72 |
| AUX, 17°F | 65 | 2.1 | 2.17 | 2.28 | 2.34 | 2.45 |
| AUX, 5°F | 65 | 1.89 | 2 | 2 | 2.1 | 2.18 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 100% | 100% | 100% | 100% | 100% |
| Rheem, 17°F | 118 | 63% | 67% | 73% | 82% | 90% |
| Rheem, 5°F | 118 | 57% | 62% | 70% | 79% | 85% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Rheem, 47°F | 118 | 2.87 | 2.97 | 3.17 | 3.44 | 3.61 |
| Rheem, 17°F | 118 | 2.11 | 2.24 | 2.38 | 2.48 | 2.61 |
| Rheem, 5°F | 118 | 1.9 | 2 | 2 | 2.1 | 2.22 |
Source: NEEP ccASHP list · as of