Skip to content

AXTELL vs Bestcold heat pumps

Measured against models of the same size and duct type, Bestcold scores higher on 5 of the 6 ratings. AXTELL has 3 outdoor models, Bestcold has 96 outdoor models. AXTELL and Bestcold have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AXTELL and Bestcold on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Bestcold scores higher on 5 of the 6 ratings.
  • AXTELL
  • Bestcold
  • Other ranked manufacturers
AXTELLBestcold

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAXTELLBestcold
Efficiency index22%median —46%median —
COP at 5°F62% (higher)median 2.2243% (higher)median 1.89
Capacity retention at 5°F3%median 53%46%median 72%
HSPF24%median 8.247%median 9.0
SEER215%median 18.151%median 18.5
EER225%median 11.340%median 11.2
Heating capacity at 5°F22%median 9,500 Btu/h48%median 18,900 Btu/h
Outdoor models396
AHRI certifications3108

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAXTELLBestcold
CEE 2025 Tier 1 (Split ASHP)66.7%2 models65.6%63 models
CEE 2026 Tier 1 (Split ASHP)66.7%2 models65.6%63 models
CEE Advanced Tier (Split ASHP)0%0 models1%1 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models62.5%60 models
DOE Cold Climate Heat Pump Challenge0%0 models1%1 models
ENERGY STAR Cold Climate0%0 models21.9%21 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 2 groups where both have models
  • AXTELL
  • Bestcold
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAXTELLBestcold
Ducted, up to 1.5 tonsNone1 · index —
Ducted, 2 tonsNone11 · index 61%
Ducted, 2.5 to 3 tonsNone11 · index 46%
Ducted, 3.5 to 4.5 tonsNone22 · index 52%
Non-ducted, up to 1.5 tons2 · index 18%32 · index 44%
Non-ducted, 2 tons1 · index 28%7 · index 37%
Non-ducted, 2.5 to 3 tonsNone9 · index 35%
Non-ducted, 3.5 to 4.5 tonsNone3 · index 29%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAXTELLCold-climate score, best modelBestcoldCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Ducted, 2 tonsNo models in this size class80.8(50 is the typical model of its size class)MYUSA24NA23BCH19-Owith ducted air handler MYUSA24NA23BCH19-I10 of 11 models qualify · AHRI 217896463
Ducted, 2.5 to 3 tonsNo models in this size class70.0(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I7 of 11 models qualify · AHRI 217896460
Ducted, 3.5 to 4.5 tonsNo models in this size class76.8(50 is the typical model of its size class)MYUSA48NA23BCH18-Owith ducted air handler MYUSA48NA23BCH18-I17 of 22 models qualify · AHRI 217896465
Non-ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)70.1(50 is the typical model of its size class)MYTW18NA23BCH24-O22 of 32 models qualify · AHRI 218599346
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)59.1(50 is the typical model of its size class)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I3 of 7 models qualify · AHRI 218078453
Non-ducted, 2.5 to 3 tonsNo models in this size class58.2(50 is the typical model of its size class)MYTW27NA23BCH24-O6 of 9 models qualify · AHRI 218599347
Non-ducted, 3.5 to 4.5 tonsNo models in this size class31.5(50 is the typical model of its size class)MYTW42NA23BCH24-O2 of 3 models qualify · AHRI 218599349

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAXTELLAll-around score, best modelBestcoldAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 1 models have all five ratings)
Ducted, 2 tonsNo models in this size class79.5(50 is the typical model of its size class)MYGA36NA23BCH19-Owith ducted air handler MYGA24NA23BCH20-I10 of 11 models have all five ratings · AHRI 217606049
Ducted, 2.5 to 3 tonsNo models in this size class66.2(50 is the typical model of its size class)MYUA36NA23BCH19-Owith ducted air handler MYUA36NA23BCH19-I9 of 11 models have all five ratings · AHRI 217896460
Ducted, 3.5 to 4.5 tonsNo models in this size class73.3(50 is the typical model of its size class)MYOA48NA22BCH18-Owith ducted air handler MYOA48NA22BCH18-I19 of 22 models have all five ratings · AHRI 217650580
Non-ducted, up to 1.5 tons29.8(50 is the typical model of its size class)AT-INV18HM2A-Owith ductless indoor unit AT-INV18HM2A-I/AT-INV18HM2A-O2 of 2 models have all five ratings · AHRI 21804361277.3(50 is the typical model of its size class) (higher)MYTW09NA23BCH25ES-Owith ductless indoor unit MYTW09NA23BCH25ES-I32 of 32 models have all five ratings · AHRI 218078450
Non-ducted, 2 tons28.1(50 is the typical model of its size class)AT-INV24HM2A-Owith ductless indoor unit AT-INV24HM2A-I/AT-INV24HM2A-O1 of 1 models have all five ratings · AHRI 21804361358.5(50 is the typical model of its size class) (higher)MYTW24NA23BCH25ES-Owith ductless indoor unit MYTW24NA23BCH25ES-I7 of 7 models have all five ratings · AHRI 218078453
Non-ducted, 2.5 to 3 tonsNo models in this size class65.9(50 is the typical model of its size class)MYTW27NA23BCH24-O9 of 9 models have all five ratings · AHRI 218599347
Non-ducted, 3.5 to 4.5 tonsNo models in this size class42.3(50 is the typical model of its size class)MYTW42NA23BCH24-O3 of 3 models have all five ratings · AHRI 218599349

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAXTELLBestcold
COP at 5°Fbeats 89% · 2.22AT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 99% · 2.44MYMBW-36NA22BCH18-ONon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 4% · 55%AT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 97% · 103%MYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18Ducted, 2 tons
HSPF2beats 4% · 8.2AT-INV12HM1A-ONon-ducted, up to 1.5 tonsbeats 84% · 9.8MYUA48NA23BCH19-ODucted, 3.5 to 4.5 tons
SEER2beats 16% · 18.1AT-INV12HM1A-ONon-ducted, up to 1.5 tonsbeats 90% · 24.0MYTW27NA23BCH24-ONon-ducted, 2.5 to 3 tons
EER2beats 39% · 11.6AT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 98% · 14.0MYUA24NA23BCH20-ODucted, 2 tons
Heating capacity at 5°Fbeats 54% · 9,500 Btu/hAT-INV18HM2A-ONon-ducted, up to 1.5 tonsbeats 97% · 25,800 Btu/hMYIRU24NA22BCH18Also listed as MYIRU24NA22BCH18Ducted, 2 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter