CIAC vs ROVSUN heat pumps
Measured against models of the same size and duct type, ROVSUN scores higher on 5 of the 6 ratings. CIAC has 3 outdoor models, ROVSUN has 82 outdoor models. CIAC and ROVSUN have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CIAC
- ROVSUN
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CIAC | ROVSUN |
|---|---|---|
| Efficiency index | 38%median — | 44%median — |
| COP at 5°F | 83% (higher)median 2.13 | 37% (higher)median 1.85 |
| Capacity retention at 5°F | 16%median 67% | 41%median 73% |
| HSPF2 | 11%median 8.0 | 52%median 9.5 |
| SEER2 | 22%median 17.0 | 51%median 20.0 |
| EER2 | 14%median 9.5 | 35%median 11.1 |
| Heating capacity at 5°F | 17%median 6,700 Btu/h | 46%median 10,750 Btu/h |
| Outdoor models | 3 | 82 |
| AHRI certifications | 4 | 91 |
Share of models meeting each standard
| Standard | CIAC | ROVSUN |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3%1 models | 78%64 models |
| CEE 2026 Tier 1 (Split ASHP) | 33.3%1 models | 78%64 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 74.4%61 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 35.4%29 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CIAC
- ROVSUN
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CIAC | ROVSUN |
|---|---|---|
| Ducted, up to 1.5 tons | None | 12 · index 54% |
| Ducted, 2 tons | None | 4 · index 47% |
| Ducted, 2.5–3 tons | None | 3 · index 45% |
| Ducted, 3.5–4.5 tons | None | 4 · index 39% |
| Non-ducted, up to 1.5 tons | 1 · index 38% | 46 · index 40% |
| Non-ducted, 2.5–3 tons | 2 · index — | 6 · index 52% |
| Non-ducted, 2 tons | None | 8 · index 45% |
| Non-ducted, 3.5–4.5 tons | None | 1 · index 27% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CIACCold-climate score, best model | ROVSUNCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 59.0(50 is the typical model of its size class)TD-09D2HRH/DVOAlso listed as TC-09CHRH/DVO-D, TSC-09HA2/I3XI23B-O, RVD-O9D2/O12 of 12 models qualify · AHRI 217154242 |
| Ducted, 2 tons | No models in this size class | 68.9(50 is the typical model of its size class)RV-AHU24S-Owith ducted air handler RV-AHU24S-I3 of 4 models qualify · AHRI 218471396 |
| Ducted, 2.5–3 tons | No models in this size class | 64.5(50 is the typical model of its size class)RV-AHU36S-Owith ducted air handler RV-AHU36S-I2 of 3 models qualify · AHRI 218471397 |
| Ducted, 3.5–4.5 tons | No models in this size class | 66.4(50 is the typical model of its size class)RV-AHU55S-Owith ducted air handler RV-AHU55S-I4 of 4 models qualify · AHRI 218471398 |
| Non-ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 68.6(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O33 of 46 models qualify · AHRI 216020714 |
| Non-ducted, 2 tons | No models in this size class | 62.6(50 is the typical model of its size class)TSC-24HA2/I3XI21B-Owith ductless indoor unit TC-24CHRH/DVIAlso listed as RVC-24/O5 of 8 models qualify · AHRI 217598675 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 57.5(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models qualify · AHRI 216020715 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 24.7(50 is the typical model of its size class)RV42M2/19-O1 of 1 models qualify · AHRI 218035868 |
All-around best
| Size and duct type | CIACAll-around score, best model | ROVSUNAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 65.2(50 is the typical model of its size class)TD-09D2HRH/DVOAlso listed as TC-09CHRH/DVO-D, TSC-09HA2/I3XI23B-O, RVD-O9D2/O12 of 12 models have all five ratings · AHRI 217154242 |
| Ducted, 2 tons | No models in this size class | 70.0(50 is the typical model of its size class)RV-AHU24S-Owith ducted air handler RV-AHU24S-I4 of 4 models have all five ratings · AHRI 218471396 |
| Ducted, 2.5–3 tons | No models in this size class | 57.9(50 is the typical model of its size class)RV-AHU36S-Owith ducted air handler RV-AHU36S-I3 of 3 models have all five ratings · AHRI 218471397 |
| Ducted, 3.5–4.5 tons | No models in this size class | 54.9(50 is the typical model of its size class)RV-AHU55S-Owith ducted air handler RV-AHU55S-I4 of 4 models have all five ratings · AHRI 218471398 |
| Non-ducted, up to 1.5 tons | 37.8(50 is the typical model of its size class)CPEA12AC1151AOwith ductless indoor unit CPEA12AC1151AH1 of 1 models have all five ratings · AHRI 218814656 | 72.2(50 is the typical model of its size class) (higher)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O46 of 46 models have all five ratings · AHRI 216020714 |
| Non-ducted, 2 tons | No models in this size class | 58.4(50 is the typical model of its size class)TSC-24HA2/I3XI21B-Owith ductless indoor unit TC-24CHRH/DVIAlso listed as RVC-24/O8 of 8 models have all five ratings · AHRI 217598675 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models have all five ratings) | 65.1(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models have all five ratings · AHRI 216020715 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 27.2(50 is the typical model of its size class)RV42M2/19-O1 of 1 models have all five ratings · AHRI 218035868 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CIAC | ROVSUN |
|---|---|---|
| COP at 5°F | beats 96% · 2.21PCG817A-X036PHB3CNon-ducted, 2.5–3 tons | beats 77% · 2.10TSC-12HA1/I3XI22B-OAlso listed as TSC-12HA1/I3XI22B-O, RV12T1/22-ONon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 16% · 67%CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 92% · 100%RV-AHU24S-ODucted, 2 tons |
| HSPF2 | beats 29% · 9.0CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 81% · 10.4TSC-24HA2/I3XI21B-OAlso listed as RVC-24/ONon-ducted, 2 tons |
| SEER2 | beats 56% · 22.0CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 91% · 24.0TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-ONon-ducted, 2.5–3 tons |
| EER2 | beats 16% · 10.0CPEA12AC1151AONon-ducted, up to 1.5 tons | beats 70% · 13.0TSC-09HA1/I3XI22B-OAlso listed as TSC-09HA1/I3XI22B-O, TSC-09HA2/I3XI23B-O, RV09T1/22-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 32% · 8,200 Btu/hCPEA12AC1151AONon-ducted, up to 1.5 tons | beats 91% · 50,000 Btu/hRV-AHU55S-ODucted, 3.5–4.5 tons |