Skip to content

Friedrich vs KANIONco heat pumps

Measured against models of the same size and duct type, KANIONco scores higher on 5 of the 6 ratings. Friedrich has 192 outdoor models, KANIONco has 56 outdoor models. KANIONco has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Friedrich and KANIONco on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KANIONco scores higher on 5 of the 6 ratings.
  • Friedrich
  • KANIONco
  • Other ranked manufacturers
FriedrichKANIONco

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingFriedrichKANIONco
Efficiency index40%median — · 28th ranked47%median —
COP at 5°F46% (higher)median 1.99 · 22nd ranked38% (higher)median 1.83
Capacity retention at 5°F36%median 51% · 27th ranked46%median 72%
HSPF232%median 7.5 · 28th ranked52%median 9.5
SEER235%median 15.2 · 28th ranked59%median 19.0
EER238%median 10.6 · 29th ranked41%median 11.1
Heating capacity at 5°F34%median 17,400 Btu/h · 28th ranked50%median 18,000 Btu/h
Outdoor models19256
AHRI certifications6,80060

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardFriedrichKANIONco
CEE 2025 Tier 1 (Split ASHP)28.1%54 models66.1%37 models
CEE 2026 Tier 1 (Split ASHP)25%48 models66.1%37 models
CEE Advanced Tier (Split ASHP)0.5%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)22.4%43 models62.5%35 models
DOE Cold Climate Heat Pump Challenge0.5%1 models0%0 models
ENERGY STAR Cold Climate21.9%42 models35.7%20 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Friedrich
  • KANIONco
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeFriedrichKANIONco
Ducted, up to 1.5 tons20 · index 31%7 · index 22%
Ducted, 2 tons23 · index 32%4 · index 55%
Ducted, 2.5 to 3 tons47 · index 36%7 · index 56%
Ducted, 3.5 to 4.5 tons59 · index 41%10 · index 49%
Ducted, 5 tons and up22 · index 36%None
Non-ducted, up to 1.5 tons20 · index 57%19 · index 51%
Non-ducted, 2 tons5 · index 52%4 · index 42%
Non-ducted, 2.5 to 3 tons4 · index 48%6 · index 52%
Non-ducted, 3.5 to 4.5 tons2 · index 47%3 · index 51%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeFriedrichCold-climate score, best modelKANIONcoCold-climate score, best model
Ducted, up to 1.5 tons73.8(50 is the typical model of its size class) (higher)FPHFR24A3Dwith ducted air handler FPHFA18A3D6 of 22 models qualify · AHRI 21750565749.4(50 is the typical model of its size class)KWSMO-18IR454BHS201 of 7 models qualify · AHRI 217048780
Ducted, 2 tons70.9(50 is the typical model of its size class) (higher)RD17AY24AJVCwith ducted air handler FRH2VY2417STACN5 of 21 models qualify · AHRI 21912594866.8(50 is the typical model of its size class)KAHU-24IR454BHS20AEwith ducted air handler KAHU-24IR454BHS20AEAlso listed as KAHUO-24IR454BHS20AE3 of 4 models qualify · AHRI 218043597
Ducted, 2.5 to 3 tons78.4(50 is the typical model of its size class) (higher)RD18AY36AJVCwith indoor coil RCFY3621MTANM and furnace FR801V0504A17UHN7 of 47 models qualify · AHRI 21689124664.5(50 is the typical model of its size class)KAHU-36IR454BHS18AEwith ducted air handler KAHU-36IR454BHS18AEAlso listed as KAHUO-36IR454BHS18AE6 of 7 models qualify · AHRI 218043598
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ducted air handler FPHFA48A3D11 of 59 models qualify · AHRI 21750887264.7(50 is the typical model of its size class)KAHU-60IR454BHS17AEwith ducted air handler KAHU-60IR454BHS17AEAlso listed as KAHUO-60IR454BHS17AE10 of 10 models qualify · AHRI 218043600
Ducted, 5 tons and up78.1(50 is the typical model of its size class)FRP17AY60AJVCwith indoor coil RCFY6024STANM and furnace FR801V1255A24UHN1 of 22 models qualify · AHRI 218328110No models in this size class
Non-ducted, up to 1.5 tons83.4(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D16 of 20 models qualify · AHRI 21423240872.4(50 is the typical model of its size class)KWSMO-18IR454BHS27R15 of 19 models qualify · AHRI 218396955
Non-ducted, 2 tons76.9(50 is the typical model of its size class) (higher)FPHFR24A3Dwith ductless indoor unit FPHFC24A3D5 of 5 models qualify · AHRI 21662615559.1(50 is the typical model of its size class)KWSM-24IR454BHS22.5R*with ductless indoor unit KWSM-24IR454BHS22.5R2 of 4 models qualify · AHRI 218399921
Non-ducted, 2.5 to 3 tons59.0(50 is the typical model of its size class)FPHFR36A3Dwith ductless indoor unit FPHSC36A3D3 of 4 models qualify · AHRI 21669960868.7(50 is the typical model of its size class) (higher)KWSMO-27IR454BHS26.5R4 of 6 models qualify · AHRI 218396956
Non-ducted, 3.5 to 4.5 tons49.8(50 is the typical model of its size class) (higher)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models qualify · AHRI 21669960948.5(50 is the typical model of its size class)KWSMO-48IR454BHS24R3 of 3 models qualify · AHRI 218396958

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeFriedrichAll-around score, best modelKANIONcoAll-around score, best model
Ducted, up to 1.5 tons68.5(50 is the typical model of its size class) (higher)FPHFR24A3Dwith ducted air handler FPHFA18A3D21 of 21 models have all five ratings · AHRI 21750565753.5(50 is the typical model of its size class)KWSMO-18IR454BHS207 of 7 models have all five ratings · AHRI 217048780
Ducted, 2 tons75.5(50 is the typical model of its size class)FRP19AY24AJVCwith ducted air handler FRHMVY3621MEACA21 of 21 models have all five ratings · AHRI 21573959379.5(50 is the typical model of its size class) (higher)KAHU-24IR454BHS20AEwith ducted air handler KAHU-24IR454BHS20AEAlso listed as KAHUO-24IR454BHS20AE4 of 4 models have all five ratings · AHRI 218043597
Ducted, 2.5 to 3 tons84.9(50 is the typical model of its size class) (higher)FRP19AY36AJVCwith ducted air handler FRHMVY3621MEACA34 of 47 models have all five ratings · AHRI 21558444067.9(50 is the typical model of its size class)KAHU-36IR454BHS18AEwith ducted air handler KAHU-36IR454BHS18AEAlso listed as KAHUO-36IR454BHS18AE7 of 7 models have all five ratings · AHRI 218043598
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class) (higher)FRP19AY48AJVCwith ducted air handler FRHMVY4821SEACA37 of 56 models have all five ratings · AHRI 21558444165.3(50 is the typical model of its size class)KAHU-48IR454BHS17AEwith ducted air handler KAHU-48IR454BHS17AEAlso listed as KAHUO-48IR454BHS17AE10 of 10 models have all five ratings · AHRI 218043599
Ducted, 5 tons and up70.6(50 is the typical model of its size class)FRP17AY60AJVCwith ducted air handler RH2TY6024STANN16 of 26 models have all five ratings · AHRI 218328406No models in this size class
Non-ducted, up to 1.5 tons85.1(50 is the typical model of its size class) (higher)FPHSR09A3Bwith ductless indoor unit FAHFW09A3AAlso listed as FPHSR09A3D20 of 20 models have all five ratings · AHRI 21423240883.7(50 is the typical model of its size class)KWSMO-18IR454BHS27R19 of 19 models have all five ratings · AHRI 218396955
Non-ducted, 2 tons63.6(50 is the typical model of its size class) (higher)FPHSR24A3Bwith ductless indoor unit FAHFW24A3AAlso listed as FPHSR24A3D5 of 5 models have all five ratings · AHRI 21409182058.5(50 is the typical model of its size class)KWSM-24IR454BHS22.5R*with ductless indoor unit KWSM-24IR454BHS22.5R4 of 4 models have all five ratings · AHRI 218399921
Non-ducted, 2.5 to 3 tons64.9(50 is the typical model of its size class)FPHMR27A3D4 of 4 models have all five ratings · AHRI 21579283983.4(50 is the typical model of its size class) (higher)KWSMO-27IR454BHS26.5R6 of 6 models have all five ratings · AHRI 218396956
Non-ducted, 3.5 to 4.5 tons49.4(50 is the typical model of its size class)FPHFR48A3Dwith ductless indoor unit FPHSC48A3D2 of 2 models have all five ratings · AHRI 21669960970.2(50 is the typical model of its size class) (higher)KWSMO-48IR454BHS24R3 of 3 models have all five ratings · AHRI 218396958

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingFriedrichKANIONco
COP at 5°Fbeats 97% · 2.40FSHSR18B3BAlso listed as FSHSR18B3DNon-ducted, up to 1.5 tonsbeats 80% · 2.03KWSM-36IR454BHS19PNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 100% · 133%FPHFR09A3DDucted, up to 1.5 tonsbeats 93% · 106%KWSM-09IR454BHS25RNon-ducted, up to 1.5 tons
HSPF2beats 91% · 9.5FRP17AY60AJVCDucted, 5 tons and upbeats 96% · 10.5KWSMO-36IR454BHS19Ducted, 2.5 to 3 tons
SEER2beats 98% · 21.0FRP19AY36AJVCDucted, 2.5 to 3 tonsbeats 99% · 26.5KWSMO-27IR454BHS26.5RNon-ducted, 2.5 to 3 tons
EER2beats 96% · 13.0RD18AY36AJVCDucted, 2.5 to 3 tonsbeats 97% · 14.0KWSMO-27IR454BHS26.5RNon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 96% · 18,600 Btu/hRD18AY24AJVCDucted, up to 1.5 tonsbeats 98% · 19,800 Btu/hKWSMO-18IR454BHS27RNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Friedrich vs KANIONco: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Friedrich (median, middle 50%)
  • KANIONco (median, middle 50%)
Heating capacity, % of its 47°F maximum71%67%COP at maximum capacity2.001.90

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
Friedrich: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F44100%100%100%100%100%
Friedrich, 17°F4460%65%68%84%92%
Friedrich, 5°F4457%62%71%74%85%
Friedrich: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Friedrich, 47°F442.82.93.083.213.46
Friedrich, 17°F442.072.22.42.52.51
Friedrich, 5°F441.891.922.092.1
KANIONco: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
KANIONco, 47°F36100%100%100%100%100%
KANIONco, 17°F3667%71%73%76%82%
KANIONco, 5°F3657%63%67%71%74%
KANIONco: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
KANIONco, 47°F362.742.883.223.53.64
KANIONco, 17°F361.952.032.122.212.3
KANIONco, 5°F361.81.81.92.12.1

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter